JQX-115F-TH中文资料
- 格式:pdf
- 大小:216.80 KB
- 文档页数:2
CJQX-10F通用型小型大功率电磁继电器2Z、3Z两种触点形式;触点切换电流可达10A;交、直流规格齐全;备有多种装置式插座选用;认证:CQC 03001003920,UL E205607,CE。
温度范围相对湿度大气压力工作位置-25℃~+55℃+25℃达95%86kPa~106kPa直立或侧立(簧片在上方)触点形式初始接触电阻触点材料触点负载(阻性)最大开关电压最大开关电流最大切换功率电气寿命(次)机械寿命(次)2Z(C)、3Z(C)100mΩ银合金10A/250VAC、10A/28VDC250VAC/125VDC10A2500VA 280W51×1071×103.3 线圈参数3.4 规格参数额定功耗吸合电压释放电压最大电压2W、3VADC:≤75%额定电压;AC:≤80%额定电压DC:≥10%额定电压;AC:≥20%额定电压110%额定电压额定电压VDC612243648110220动作电压VDC(≤)4.59.018.027.036.082.5165.0释放电压VDC(≥)0.61.22.43.64.811.022.0线圈电阻Ω±10%248036084016007560290003.2 性能、特征参数绝缘电阻介质耐压动作时间释放时间冲击(稳定性)振动引出端形式外形尺寸(mm)触点线圈间,异组触点间断开触点间100MΩ(500VDC)1500VAC1000VAC≤20ms≤20ms2加速度100m/s,脉冲持续时间11ms双振幅1mm,10~55Hz插拔式35×35×533.1 触点参数1 适用范围2 正常工作条件和安装条件3 主要参数及技术性能4 配套插座(备选)额定电压VAC 6122448110220380动作电压VAC(≤)4.89.619.238.488.0176.0304.0释放电压VAC(≥)1.22.44.89.6224476线圈电阻Ω±10%7198040016007300225005 外形及安装尺寸2Z:二组转换3Z:三组转换-:直流直流6~220V 交流6~380VCZF08A-E 52×41×21.5JQX-10F/2Z CZF08A 52×41×21.5螺钉型接线端子(装置式、导轨式)继电器型号配用插座型号插座外形尺寸(mm)插座引线形式CZF11A-E 52×44×31JQX-10F/3Z CZF11A 52×44×31螺钉型接线端子(装置式、导轨式)继电器型号配用插座型号插座外形尺寸(mm)插座引线形式6 订货须知。
2 正常工作条件和安装条件20A触点切换能力;交/直流规格齐全;透明防尘罩封装,安装方式多样;备有各种插座选用;可选带状态指示灯的规格。
JQX-13FA小型大功率电磁继电器3.3 线圈参数3.4 规格参数额定功耗吸合电压释放电压最大电压0.9W、1.2VADC:≤75%额定电压;AC:≤80%额定电压DC:≥10%额定电压;AC:≥20%额定电压110%额定电压温度范围相对湿度大气压力工作位置-30℃~+60℃+40℃达90%86kPa~106kPa 任意额定电压VDC 5612243648110127220动作电压VDC(≤)3.754.59.018.027.036.082.595.3165.0释放电压VDC(≥)0.50.61.22.43.64.811.012.722.0线圈电阻Ω±10%2844160640144025601450017000390001H(A)、1D(B)、1Z(C)100mΩ银合金20A/220VAC、20A/28VDC 250VAC/125VDC 20A4400VA 560W 51×1071×103.2 性能、特征参数绝缘电阻介质耐压动作时间释放时间冲击(稳定性)振动引出端形式外形尺寸(mm)线圈轭轶间,异组触点间断开触点间100MΩ(500VDC)1500VAC 1000VAC ≤25ms ≤25ms2加速度100m/s ,脉冲持续时间11ms 双振幅1mm,10~55Hz 插拔式、PCB式27.5×21.5×35.5触点形式初始接触电阻触点材料触点负载(阻性)最大开关电压最大开关电流最大切换功率电气寿命(次)机械寿命(次)3.1 触点参数1 适用范围3 主要参数及技术性能额定电压VAC 612243648110127220380动作电压VAC(≤)4.89.619.228.838.488.0101.6176.0304.0释放电压VAC(≥)1.22.44.87.29.62225.44476线圈电阻Ω±10%10.5441803806503670410014500390004 配套插座(备选)继电器型号配用插座型号插座外形尺寸(mm)插座引线形式CZT08A -E 79×29×33JQX -13FA螺钉型接线端子(装置式、导轨式)5 外形及安装尺寸注:对于订货示例中引出端形式为单引出规格,只保留端子编号2、3、6、7、8的引出端。
宏发115f继电器的说明书宏发115F继电器说明书第一章:产品概述宏发115F继电器是一种高性能、高可靠性的电气开关设备。
它采用先进的电磁原理,可以将微弱的控制信号(通常为毫安级别)转换成大电流的输出信号,用于控制各种电气设备的启停和方向变换。
本继电器具有安装简便、体积小巧、操作可靠等特点。
第二章:型号与规格宏发115F继电器提供多种型号和规格,以满足不同的用户需求。
主要规格包括:负荷电压、负荷电流、接线方式、工作温度范围等。
用户在选型时应根据具体需求综合考虑各项指标,选择适合的型号。
第三章:安装与连接1. 安装要求:宏发115F继电器适用于安装在干燥、无腐蚀性气体的室内环境中。
在安装时应注意保持良好的通风和散热条件。
2. 连接方式:本继电器支持多种接线方式,包括直流串联、直流并联、交流系列、交流并联等。
用户应根据实际应用需求选择合适的接线方式,并按照图示正确连接。
第四章:操作与维护1. 操作注意事项:在进行操作时,用户应先确保继电器的控制信号和电源电压是否符合要求,以保证正常工作。
操作时应轻拿轻放,避免碰撞和振动。
2. 维护保养:宏发115F继电器采用密封结构,无需定期保养。
但在使用过程中,应定期检查接线是否松动,继电器表面是否有灰尘积聚,并及时清理。
第五章:故障排除与常见问题解答1. 继电器无法工作:可能是控制信号不稳定、电源电压不足等原因造成的。
用户应检查控制信号和电源电压是否正常,如有异常应进行排除。
2. 继电器发热过高:可能是负荷过大、外界温度过高等原因导致的。
用户应重新评估负荷和环境条件,避免长时间超负荷运行。
第六章:安全警示与注意事项1. 本继电器仅适用于低压电路,禁止直接接触高压电源。
2. 在拆卸和维修继电器时,应确保断开电源,避免触电危险。
3. 禁止将本继电器用于超出规定范围的工作条件下,以免损坏设备和引发安全事故。
第七章:环保与回收宏发115F继电器采用环保材料制造,符合国家相关法规和标准,环境友好。
DESCRIPTIONThe System Sensor 1151low profile ionization type smoke detectors are specifically designed to meet the performance requirements of fire detection/alarm systems.The 1151ion-ization detector uses a state-of-the-art,dual unipolar sensing chamber.The detector is designed to provide open area de-tection and,when installed in a two-wire base,is compatible with FCI fire alarm control panels.The detector’s operation and sensitivity can be tested in place.The 1151detector is of plug-in construction and plugs into the same base as the System Sensor 2151photoelectronic smoke detector,making both models interchangeable.Bases are available for two-wire,four-wire,120V AC four-wire op-eration and also with an audible sounder.Two visible LEDs on each detector flash every ten seconds indicating that power is being applied to the detector.The LEDs light steadily when the detector is in alarm.A remote LED annunciator is available as an optional accessory.The 1151detector is Listed for use inside ducts up to a ve-locity of 500FPM.Functional testing is performed by placing a test magnet against the cover.The LED on the detector should light within 30seconds.Field metering of detector sensitivity may be performed with the aid of a voltmeter and Test Kit,MOD 400R.APPROV ALSSPECIFICATIONSSensitivity1.9%/ft.(nominal)Operating voltage 15-32VDC peak Standby current200uA max.avg.Operating temperature 32to 120o F (0to 49o C)Relative humidity 10to 93%(non-condensing)Air velocity 500feet per minute maximum Construction Off-white flame retardant plastic Diameter 4inches (10.2cm)Height 1.7inches (4.2cm)Weight3.6oz.(104g)1151SYSTEM SENSORLOW PROFILE,IONIZATION PLUG-IN SMOKE DETECTOR9020-0582/Ver.1.116Southwest Park,Westwood,MA 02090USA TEL:(781)471-3000FAX:(781)471-3099Specifications are provided for information only,are not intended to be used for installation purposes,and are believed to be accurate.However,no responsibility is assumed by Fire Control Instruments,Inc.for their use.Specifications subject to change without notice.©2003All Rights ReservedFEATURESUnique Dual Unipolar Sensor Provides Exceptional Stability Low Profile ConstructionEasy plug-in of the Head to Base Tamper-resistant Feature Test Switch360o View Angle Of Alarm LEDs Compatible with FCI Control Panels Audible Sounder Base (Optional)Field Metering of Detector Sensitivity Removable Insect Screen and Cover for Field CleaningInsect-resistant Screening (.020"/.508mm openings)An ISO 9001CertifiedCompanyMOUNTINGOn a4-inch square box with or without plasterring.Minimum depth1.5inches.On a3.5-inch octagonal box.Minimum depth1.5inches.INSTALLATIONPlace the detector into the detector base.Turn the de-tector clockwise until the detector locks into place. To use the tamper-proof feature,break the smaller tab on the scribed line in the tamper proof tab located on the detector mounting bracket.Install the detector.To re-move the detector from the base when using the tam-per-proof feature,insert the blade of a small screwdriver into the hole on the side of the base and push the plastic lever away from the detector head.This will allow the detector to be rotated counterclockwise for removal.NOTE:The decorative ring must be re-moved in order to remove the head when using the tam-per-proof feature.The tamper-proof feature may be defeated perma-nently by breaking the plastic lever off the base. NOTE:The number of two-wire smoke detectors which can be accommodated per zone varies with dif-ferent control panels.Consult the control panel in-struction manual to determine the capacity.Refer to NFPA72,Chapter5-3,“Smoke Sensing Fire Detectors”for spacing,location of detectors and other guidelines.TESTINGDetectors may be tested in the following ways: Place a test magnet against the detectoras directed in the installation instructions.The detector should go into alarm within30seconds.Field metering of detector sensitivity may beperformed with the aid of a voltmeter and Test Kit,MOD400R.For the complete procedure,refer to the Installation and MaintenanceInstructions furnished with each detector.MAINTENANCECleaning programs should be adapted to the individ-ual environment.We recommend at least an annual cleaning of the unit.The detector screen and cover as-sembly can be removed,revealing the sensing cham-ber.A vacuum cleaner can be used to remove dust from the screen,cover and sensing chamber.For the com-plete procedure,refer to the Installation and Mainte-nance Instructions furnished with each detector.2of29020-0582 ORDERING AND TECHNICAL INFORMATIONModel Contacts Description1151Ionization DetectorB110LP Base,Two-wireB112LP Form A&C Base,four-wire,24VDC operationB114LP Form A,C&Supv.Base,four-wire,120V AC operationB401BH Base,four-wire,with audible sounderRA-400Z Remote Alarm IndicatorPAM-1Form B End of Line Relay,24VDCMOD400R Test Kit。