Parker内部冶金缸样本
- 格式:ppt
- 大小:17.02 MB
- 文档页数:53
aerospaceclimate control electromechanical filtrationfluid & gas handling hydraulics pneumatics process control sealing & shielding1Safety Information (1)1.1Markings and Symbols (1)2Description (2)2.1Stages of Purification (2)2.2Technical Specification (2)2.2.1Pressure Correction Factors (2)2.3Weights and Dimensions (3)2.4Receiving and Inspecting the Equipment (4)2.4.1Storage (4)2.4.2Unpacking (4)2.4.3Overview of the Equipment (5)3Installation & Commissioning (6)3.1Recommended system layout (6)3.2Locating the Equipment (7)3.2.1Space Requirements (7)3.3Mechanical Installation (7)3.3.1General Requirements (7)3.3.2Securing the Unit (7)4Operating the Equipment (8)4.1Starting the Equipment (8)5Servicing (9)5.1Cleaning (9)5.2Service Intervals (9)5.3Preventative Maintenance Kits (10)5.4Maintenance Procedures (11)5.4.1Cartridge Replacement Procedure (PCO2-400 Models Only) (11)5.4.2OIL-X Element Change Procedure (13)5.4.3Cartridge Replacement Procedure (PCO2-800 to PCO2-4800 Models) (14)5.4.4IP50 Element Change Procedure (16)6Troubleshooting (17)1 Safety InformationDo not operate this equipment until the safety information and instructions in this user guide have been read and understood by all personnel concerned.USER RESPONSIBILITYFAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.This document and other information from Parker Hannifin Corporation, its subsidiaries and authorised distributors provide product or system options for further investigation by users having technical expertise.The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyse all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalogue and in any other materials provided from Parker or its subsidiaries or authorised distributors.To the extent that Parker or its subsidiaries or authorised distributors provide component or system options based upon data or specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems.Only competent personnel trained, qualified, and approved by Parker Hannifin should perform installation, commissioning, service and repair procedures.With the exception of oxygen, any gas can cause asphyxiation in high enough concentrations. Always ensure that the unit is operated in a well ventilated area and all of the vent ports on the rear of the unit are kept clear and free from blockages.Use of the equipment in a manner not specified within this user guide may result in an unplanned release of pressure, which may cause serious personal injury or damage.When handling, installing or operating this equipment, personnel must employ safe engineering practices and observe all related regulations, health & safety procedures, and legal requirements for safety.Ensure that the equipment is depressurised prior to carrying out any of the scheduled maintenance instructions specified within this user guide. Parker Hannifin can not anticipate every possible circumstance which may represent a potential hazard. The warnings in this manual cover the most known potential hazards, but by definition can not be all-inclusive. If the user employs an operating procedure, item of equipment or a method of working which is not specifically recommended by Parker Hannifin the user must ensure that the equipment will not be damaged or become hazardous to persons or property.Most accidents that occur during the operation and maintenance of machinery are the result of failure to observe basic safety rules and procedures. Accidents can be avoided by recognising that any machinery is potentially hazardous.Should you require an extended warranty, tailored service contracts or training on this equipment, or any other equipment within the Parker Hannifin range, please contact your local Parker Hannifin office.Details of your nearest Parker Hannifin sales office can be found at /gsfeRetain this user guide for future reference.Related Documents:• Preventative Maintenance Guide 176070002• 12 Month Service Instructions 1760700031.1 Markings and SymbolsThe following markings and international symbols are used on the equipment or within this manual:2 DescriptionThe Parker domnick hunter PCO2 systems offer a comprehensive solution to preserve and guarantee the quality of gaseous carbon dioxide used in sparkling beverage bottling.Operating as a Quality Incident Protection system against potential carbon dioxide impurities, the system guarantees the gas quality so itremains within industry and company guidelines, preventing detrimental consequences to the finished end beverage, producers reputation and their bottom-line.PCO2 is the beverage industry preferred choice and is installed in over 150 countries worldwide.2.1 Stages of Purification* Optional - Sterilising Grade: consult Parker for operational use.2.2 Technical SpecificationThis specification is valid when the equipment is located, installed, operated, and maintained as specified within this user guide.Stated flow rates are at 24.1 bar g (350 psi g).*Systems are installed in duplex / parallel to double the flow rate.All systems are supplied as NPT with stainless steel adapters 'NPT to BSP' as standard.PCO2 CO 2 systems are for gaseous CO 2 only.For flows at other pressures, apply the correction factors shown below.2.2.1 Pressure Correction FactorsStage 10.01 micron particle filtrationRemoval of non-volatile organic residue (NVOR) and other contaminants down to 0.01 ppmStage 2Removal of water vapour and partial removal of hydrocarbonsStage 3Primary removal of aromatic hydrocarbons (Benzene, Toulene etc and Acetaldehyde)Stage 4Removal of sulphur compounds (COS, H2S, DMS etc)Stage 50.01 micron particle filtrationStage 6*Point of use VBACE sterile gas membrane. Hi Flow Tetpor II ParameterUnitsPCO2400PCO2800PCO21600PCO22400PCO23200PCO24000PCO24800PCO23200(Duplex)*PCO24000(Duplex)*PCO24800(Duplex)*Technical DataMinimum Operating Pressure bar g (psi g) 3.0(43.5) 3.0(43.5) 3.0(43.5) 3.0(43.5) 3.0(43.5) 3.0(43.5) 3.0(43.5) 3.0(43.5) 3.0(43.5) 3.0(43.5)Maximum Operating Pressure bar g (psi g)20.7(300)24.1(350)24.1(350)24.1(350)24.1(350)24.1(350)24.1(350)24.1(350)24.1(350)24.1(350)Minimum Operating Temperature ºC (ºF)-20(-4)-20(-4)-20(-4)-20(-4)-20(-4)-20(-4)-20(-4)-20(-4)-20(-4)-20(-4)Maximum Operating Temperature ºC (ºF)40(104)40(104)40(104)40(104)40(104)40(104)40(104)40(104)40(104)40(104)Inlet CO 2 Quality ISBT beverage grade CO 2FlowrateKg / hr 1813637261089145118142177290336284354Lb / hr40080016002400320040004800640080009600Port Connections CO 2 Inlet in 1” NPT 1-1/2" NPT CO 2 Outletin1” NPT1-1/2" NPTInlet Pressurebar g 345678*********psi g44587387102116130145160174189Correction Factor 0.190.230.280.330.380.420.470.520.570.610.66Inlet Pressurebar g 1415161718192021222324psi g203218232247261275290304319333350Correction Factor0.710.760.800.850.900.95111112.3 Weights and Dimensions*Clearance required for the removal and servicing of the cartridges.Model Height (H)Width (W)Depth (D)(a)(b)(c)Clearance*Weight mm ins mm ins mm ins mm ins mm ins mm ins mm ins kg Ibs PCO2-400103540.7556422.2035013.78189.57.534013.430011.8168026.875165PCO2-800106141.7763224.8845017.72215.58.534013.440015.7568026.884185PCO2-1600106141.7780131.5445017.72215.58.550920.0440015.7568026.8128282PCO2-2400106141.7797038.1945017.72215.58.567826.7040015.7568026.8172379PCO2-3200106141.77113944.8445017.72215.58.584733.3540015.7568026.8217478PCO2-4000106141.77130851.5045017.72215.58.5101640.040015.7568026.8260573PCO2-4800106141.77147758.1545017.72215.58.5118546.740015.7568026.8304670(b)(b)PCO2-400PCO2-800 to PCO2-48002.4 Receiving and Inspecting the EquipmentOn receipt of the equipment carefully inspect the packaging for damage. If the packaging is damaged inform the delivery company immediately and contact your local Parker Hannifin office.2.4.1 StorageIf the equipment is to be stored prior to installation, do not remove it from the packaging. Ensure that it is stored in an upright position as indicated by the arrows on the packaging.Do not attempt to lift the equipment by yourself. It is recommended that the equipment be carried by a minimum of two persons ortransported on a pallet truck.Note. The storage area should be secure and the environmental conditions should fall within those specified in the technical specification.If the equipment is stored in an area where the environmental conditions fall outside of those specified, it is essential that it be moved to its final location (installation site) and left to stabilise prior to unpacking. Failure to do this could cause condensing humidity and potential failure of the equipment.2.4.2 UnpackingRemove the lid and all four sides of the packing crate. Carefully move the unit to its final location using a forklift truck or pallet truck. Once in it’s final location, remove the unit from the pallet via the 4x bolts.Note: Suitable slings and an overhead crane maybe required depending on the product size.2.4.3 Overview of the EquipmentKey:Item Description1System Inlet2System Outlet3AA020P OIL-X Filter (PCO2-400 Models only) IP50-AA-0465GPCO2 Filter4Manual Filter Drain5Manifold Lifting Handle6Manifold Hinge (PCO2-800 to PCO2-4800 Models) 7Desiccant Cartridge8PCO2 Column9Pressure Gauge10Lifting Eye Bolt7 8PCO2-400PCO2-800 to PCO2-4800 73 Installation & Commissioning3.1 Recommended system layoutOnly competent personnel trained, qualified, and approved by Parker Hannifin should perform commissioning and service procedures.1Liquid CO2 storage tank 2Vaporiser3Stainless steel piping4Pre filtration - Stage One 5PCO2 Unit6Post filtration - Stage five 7Isolation valves8Sterile Filter (Optional)54678 2313.2 Locating the Equipment3.2.1 Space RequirementsThe equipment should be mounted on a flat surface capable of supporting its own weight plus the weight of all ancillary parts. The minimum footprint requirements are specified below, however there must be adequate space around the equipment to allow airflow and access for maintenance purposes and lifting equipment. A minimum spacing of approximately 500mm (20 ins) is recommended around all sides of the unit and 750mm (30 ins) above it.Do Not position the equipment so that it is difficult to operate.3.3 Mechanical Installation3.3.1 General RequirementsEnsure that all piping materials are suitably rated for the application, clean and debris free. The diameter of the pipes must be sufficient to allow unrestricted inlet air supply to the equipment.Apply approximately 8 - 12 turns of P .T.F.E tape to the high quality stainless steel piping.Fit the piping along with the relevant pre and post filtration onto the inlet and outlet. Isolation valves must be installed before the inlet filtration and after the outlet filtration.When routing pipes ensure that they are adequately supported to prevent damage or leaks in the system.All components used within the system must be rated to at least the maximum operating pressure of the equipment. It is recommended that the system is protected with suitably rated pressure relief valves.3.3.2 Securing the UnitMounting holes are provided in the feet of the unit. Once the unit has been positioned in its final location ensure that it is securely fixed in place.500mm (20ins)(20ins)500mm(20ins)4 Operating the Equipment4.1 Starting the EquipmentNote: On start-Up it is normal for the outlet temperature to increase for a limited period of time.1 Open the inlet valve slowly to gradually pressurise the PCO2 unit.2 Open the outlet valve slowly to re-pressurise the downstream piping.Do not open the inlet or outlet valves rapidly or subject the PCO2 unit to excessive pressure differential as damage may occur.5 Servicing5.1 CleaningClean the equipment with a damp cloth only. If required you may use a mild detergent, however do not use abrasives or solvents as they may damage the warning labels on the equipment.5.2 Service IntervalsParker recommend that the adsorbent cartridges and filter elements are exchanged within the recommended 12-month period or before the recorded cumulative mass of the unit has been exceeded or after a quality incident has occurred, whichever comes first. Please refer to the below table for the maximum mass flow of each model.Service12 M o n t h s24 M o n t h s36 M o n t h s48 M o n t h s60 M o n t h s72 M o n t h sAPCO2 Model Number Max Operating Pressure Bar/PSI Flow kg/hr @ Max OperatingPressureMax Mass over 12 Months:kgFlow lb/hr@ Max OperatingPressureMax Mass over 12 Months:IbMax Mass over 12 Months: Tonne (Metric Ton)PCO2-40020 Barg / 300 PSIG 181158121640034944001581PCO2-80024 Barg / 350 PSIG 363317116880069888003170PCO2-160024 Barg / 350 PSIG 72663423361600139776006340PCO2-240024 Barg / 350 PSIG 108995135042400209664009510PCO2-320024 Barg / 350 PSIG 14511267593632002795520012680PCO2-400024 Barg / 350 PSIG 18141584710440003494400015850PCO2-480024 Barg / 350 PSIG 21771901827248004193280019020PCO2-3200 (Duplex)24 Barg / 350 PSIG 29032536060864005591040025361PCO2-4000 (Duplex)24 Barg / 350 PSIG 36283169420880006988800031701PCO2-4800 (Duplex)24 Barg / 350 PSIG435438036544960083865600380415.3 Preventative Maintenance KitsRequired every 8000Hrs (12 months)PCO2-400PCO2-800 to PCO2-4800AAAModelPM Kit NumberKit ContentsOrder QuantityPCO2 400MK-PCO2-4001x Desiccant cartridges 2x Outlet block o-rings 2x P020AA Filter element 2x Filter bowl o-rings 1PCO2 800MK-PCO2-8002x Desiccant cartridges 2x Outlet block o-rings 2x IP50-AA Filter element 2x Filter bowl o-rings 1PCO2 1600MK-PCO2-16004x Desiccant cartridges 2x Outlet block o-rings 2x IP50-AA Filter element 2x Filter bowl o-rings 1PCO2 2400MK-PCO2-24006x Desiccant cartridges 2x Outlet block o-rings 2x IP50-AA Filter element 2x Filter bowl o-rings 1PCO2 3200MK-PCO2-32008x Desiccant cartridges 2x Outlet block o-rings 2x IP50-AA Filter element 2x Filter bowl o-rings 1PCO2 4000MK-PCO2-400010x Desiccant cartridges 2x Outlet block o-rings 2x IP50-AA Filter element 2x Filter bowl o-rings 1PCO2 4800MK-PCO2-480012x Desiccant cartridges 2x Outlet block o-rings 2x IP50-AA Filter element 2x Filter bowl o-rings 1PCO2 3200 (Duplex)MK-PCO2-640016x Desiccant cartridges 4x Outlet block o-rings 4x IP50-AA Filter element 4x Filter bowl o-rings 1PCO2 4000 (Duplex)MK-PCO2-800020x Desiccant cartridges 4x Outlet block o-rings 4x IP50-AA Filter element 4x Filter bowl o-rings 1PCO2 4800 (Duplex)MK-PCO2-960024x Desiccant cartridges 4x Outlet block o-rings 4x IP50-AA Filter element 4x Filter bowl o-rings1With OIL-X IP50 filter elements (PCO2-800 to PCO2-4800)With OIL-X filter elements (PCO2-400 Models only)5.4 Maintenance Procedures5.4.1 Cartridge Replacement Procedure (PCO2-400 Models Only)Ensure that the system is fully depressurised before carrying out the below maintenance procedures.A Remove the M12 nuts from one side of the manifold.B Using the handle, carefully lift and remove the manifold from the unit and store in a safe place.Ensure that the inlet and outlet piping is adequately supported before removing the manifold from the unit.C Remove the old desiccant cartridges and dispose in accordance with local regulations.D Remove the o-ring from the outlet manifold block and replace with the one provided within the 12 month Preventative Maintenance kits.Note: Apply a light coating of Molykote III grease to the o-rings.E Insert the replacement desiccant cartridges into the columns.F Refit the manifold and secure the M12 nuts in sequence, starting with the centre nuts and working outwards. The nuts should be secured intwo stages. Stage 1: 27Nm (20 ft.lb) and Stage 2: 40Nm (30 ft.lb).A5.4.2 OIL-X Element Change ProcedureA Ensure that the filters are fully depressurised by opening the manual drain.B Unscrew the filter bowl and remove the used element.C Replace the o-ring located on the filter bowl with the new one provided within the 12month Preventative Maintenance kits.D Insert the new element into the filter bowl ensuring that the lugs are correctly seated inthe grooves.E Refit the filter bowl to the head ensuring that the threads are fully engaged and thelocking details are aligned.F Close the manual drain and re-pressurise the system.We recommend the use of gloves when touching contaminated elements.Ensure to lubricate the o-ring and threads with Molykote III grease.Item Description Item Description1Filter head4Filter bowl o-ring2Filter bowl5Manual Drain3Element5.4.3 Cartridge Replacement Procedure (PCO2-800 to PCO2-4800 Models)The top manifold has been split into two sections in order to simplify the removal of the desiccant cartridges.Ensure that the system is fully depressurised before carrying out the below maintenance procedures.A Remove the M12 nuts from one side of the manifold.B Using the handles, carefully lift the manifold until the M8 hex bolt has travelled to the top of the manifold hinge. Gently pull the manifoldtowards yourself until it has locked into position.C Carefully rotate the manifold 180o as shown. Once opened, place an M10 locking bolt through the holes in the two halves of the hinges toprevent the manifold falling onto the operator during service.Take care not to trap fingers/hands on the handles when rotating the manifold.D Remove the old desiccant cartridges and dispose in accordance with local regulations.Note: The cartridges should only be lifted using the handles and directly upwards to prevent clashing with the hinged manifold.E Remove the o-ring from the outlet manifold block and replace with the one provided within the 12 month Preventative Maintenance kits.Note: Apply a light coating of Molykote III grease to the o-rings.F Insert the replacement desiccant cartridges into the columns.Refit the manifold and secure the M12 nuts in sequence, starting with the centre nuts and working outwards. The nuts should be secured in two stages. Stage 1: 27Nm (20 ft.lb) and Stage 2: 40Nm (30 ft.lb).Replace the desiccant cartridges on the opposite side following the same procedure as above.5.4.4 IP50 Element Change ProcedureA Ensure that the filters are fully depressurised by opening the 1/4” BSPT ball valves.B Unscrew the filter bowl and then the used element from the tie rod.C Replace the o-ring located on the filter bowl with the new one provided within the 12month Preventative Maintenance kits.D Fit the new element onto the tie rod and tighten.E Refit the filter bowl to the head ensuring that the threads are fully engaged.F Close the 1/4” BSPT ball valves and re-pressurise the system.We recommend the use of gloves when touching contaminated elements.Ensure to lubricate the o-ring and threads with Molykote III grease.Item Description Item Description1Filter head4Element2Filter bowl5Filter bowl o-ring3Tie rod61/4” BSPT ball valve6 TroubleshootingProblem Indication Possible Cause Action RequiredPoor dewpoint Condensed water downstream ofthe system Bulk water carried over into thePCO2 unitCheck pre-filtration elements anddrainsOverflow of the PCO2 unitCompare flow through the PCO2unit to rated flowCheck for modifications to thecompressed air systemInlet pressure too low Check functioning of thecompressorInlet temperature too highCheck functioning of thecompressorCheck ventilation around the dryer Contaminated desiccantLocate and eliminate source ofcontamination and replace thedesiccantHigh pressure drop through filter / system package Pressure gauges fitted tocompressor / trainBlocked filters Replace any blocked filtersOverflow of the PCO2 unit Eliminate conditions leading toover flowOutlet air flow stops Indicated downstream pressuredrops to zero Compressor failure Investigate problem with the compressor and correctEU /-EC Type-examination Certificate:COV0912556/1Notified body for PED:Notified Body for ATEX:----B + DPED Assessment Route:29 April 2019Steven RohanDate:Signature:Parker Hannifin Manufacturing Limited GSFEDeclaration Number:00308Authorised Representative29.4.19--Lloyd's Register Verification 71 Fenchurch Street,London, EC3M 4BS-Standards used----Parker Hannifin Manufacturing Limited GSFEDukesway,Team Valley Trading Estate,Gateshead, Tyne & Wear,NE11 0PZ, UK PCO2 Carbon Dioxide Quality Incident Protection SystemGenerally in accordance with ASME VIII Div 1:2017and AS1210:2010PED----ENDeclaration of Conformity-Division Engineering Manager,This declaration of conformity issued under the sole responsibility of the manufacturer.DeclarationDirectives2014/68/EU -------PEDPCO2-400, PCO2-800, PCO2-1600, PCO2-2400, PCO2-3200, PCO2-4000, PCO2-4800Parker Hannifin Manufacturing Limited Gas Separation and Filtration Division EMEA Dukesway, Team Valley Trading Est Gateshead, Tyne and Wear England NE11 0PZTel: +44 (0) 191 402 9000Fax: +44 (0) 191 482 /gsfe© Parker Hannifin Corporation. All rights reserved.Catalogue: 176********/20 Rev: AEurope, Mi dd le East, AfricaAE – Unite d Arab Emirates, DubaiTel: +971 4 8127100********************AT – Austria, Wiener Neustadt Tel: +43 (0)2622 23501-0*************************AT – Eastern Europe, Wiener NeustadtTel: +43 (0)2622 23501 900****************************AZ – Azerbaijan, Baku Tel: +994 50 2233 458****************************BE/LU – Bel g ium, Nivelles Tel: +32 (0)67 280 900*************************BY – Belarus, Minsk Tel: +375 17 209 9399*************************CH – Switzerlan d , Etoy Tel: +41 (0)21 821 87 00*****************************CZ – Czech Republic, Klecany Tel: +420 284 083 111*******************************DE – Germany, Kaarst Tel: +49 (0)2131 4016 0*************************DK – Denmark, Ballerup Tel: +45 43 56 04 00*************************ES – Spain, Madrid Tel: +34 902 330 001***********************FI – Finlan d , Vantaa Tel: +358 (0)20 753 2500parker.fi ****************FR – France, Contamine s/Arve Tel: +33 (0)4 50 25 80 25************************GR – Greece, Athens Tel: +30 210 933 6450************************HU – Hun g ary, Budapest Tel: +36 1 220 4155*************************IE – Irelan d , Dublin Tel: +353 (0)1 466 6370*************************IT – Italy, Corsico (MI)Tel: +39 02 45 19 21***********************KZ – Kazakhstan, Almaty Tel: +7 7272 505 800****************************NL – The Netherlan d s, Oldenzaal Tel: +31 (0)541 585 000********************NO – Norway, Asker Tel: +47 66 75 34 00************************PL – Polan d , Warsaw Tel: +48 (0)22 573 24 00************************PT – Portu g al, Leca da Palmeira Tel: +351 22 999 7360**************************RO – Romania, Bucharest Tel: +40 21 252 1382*************************RU – Russia, Moscow Tel: +7 495 645-2156************************SE – Swe d en, Spånga Tel: +46 (0)8 59 79 50 00************************SK – Slovakia, Banská Bystrica Tel: +421 484 162 252**************************SL – Slovenia, Novo Mesto Tel: +386 7 337 6650**************************TR – Turkey, Istanbul Tel: +90 216 4997081************************UA – Ukraine, Kiev Tel +380 44 494 2731*************************UK – Unite d Kin gd om, Warwick Tel: +44 (0)1926 317 878********************ZA – South Africa, Kempton Park Tel: +27 (0)11 961 0700*****************************North AmericaCA – Cana d a, Milton, Ontario Tel: +1 905 693 3000US – USA, Cleveland Tel: +1 216 896 3000Asia Pacifi cAU – Australia, Castle Hill Tel: +61 (0)2-9634 7777CN – China, Shanghai Tel: +86 21 2899 5000HK – Hon g Kon g Tel: +852 2428 8008IN – In d ia, MumbaiTel: +91 22 6513 7081-85JP – Japan, Tokyo Tel: +81 (0)3 6408 3901KR – South Korea, Seoul Tel: +82 2 559 0400MY – Malaysia, Shah Alam Tel: +60 3 7849 0800NZ – New Zealan d , Mt Wellington Tel: +64 9 574 1744SG – Sin g apore Tel: +65 6887 6300TH – Thailan d , Bangkok Tel: +662 186 7000-99TW – Taiwan, Taipei Tel: +886 2 2298 8987South AmericaAR – Ar g entina, Buenos Aires Tel: +54 3327 44 4129BR – Brazil, Sao Jose dos Campos Tel: +55 800 727 5374 CL – Chile, Santiago Tel: +56 2 623 1216MX – Mexico, Apodaca Tel: +52 81 8156 6000Parker WorldwideEuropean Pro d uct Information Centre Free phone: 00 800 27 27 5374(from AT, BE, CH, CZ, DE, DK, EE, ES, FI, FR, IE, IL, IS, IT, LU, MT, NL, NO, PL, PT, RU, SE, SK, UK, ZA)。
美国派克PARKER气缸,parker液压油缸知识介绍美国parker派克气缸:派克汉尼汾的Parker气缸用于液压,气动,电气和航空航天系统的气缸,包含单杆,双杆和无杆设计的气缸。
具有广泛的安装方式,材料,密封符合选项,反馈协议和结构类型,从轻型铝制空气气缸,到用于移动或工业设备的重型液压设计,再到用于航天航空应用的制动和执行器气缸。
Parker派克气缸派克P1D标准气缸全新的,革新的P1D气缸是派克汉尼汾公司推出的一种能经受得住未来考验的一代ISO/VDMA 气缸。
这种气缸是双作用的,带有新型的气缓冲。
质量轻,硬度高的缸筒有传感器沟槽,使得传感器安装简单,并可保护传感器。
派克气缸派克P1D标准气缸安装尺寸符合国际标准新的P1D气缸符合现有的ISO6431,ISO/DIS15552,VDMA24562和AFNOR安装尺寸标准。
确保世界范围的客户使用。
高技术设计为了能提供最好的产品,我们选用了最好的材料,最好的加工方法,对每个细节处的设计都进行仔细的测试和试验。
气缸内部的元是高强度塑料做成的,这样使得气缸运动平稳,无噪声,使用寿命长。
铝合金端盖和抗扭矩的铝合金缸筒使气缸耐用并适用于很多种应用场合。
高质量P1D气缸在以下的每一阶段都是经过高质量开发的-规格需求,设计,计划,采购,生产,分销和服务。
我们在10年前就通过了ISO9001 QA标准的质量认证。
产品和服务的高质量是我们的口号。
更多的功能和不同P1D气缸有所有通用功能的设计,比如:双活塞杆气缸,高/低温气缸,液压操作气缸,加长活塞杆气缸等。
新的特殊的不同点是P1D气缸具有*的自润滑型HDPE刮尘圈和活塞杆密封,这种特殊的设计适用于需要活塞杆完全干燥的场合(如活塞杆上的油脂层经常被冲洗掉的场合)。
Parker派克液压油缸的保养说明因为液压油缸要承受很大的压强,负载越重,它的压强就会越大,因此,做好液压油缸的保养工作是整个液压系统的维护zui重要的一环。
Y-HG1液压缸样本Y-HG型冶金设备用标准液压缸 1Y-HG型冶金设备用标准液压缸共有34种规格,68个品种,缸径40,320mm。
1 技术特点1.压力:本标准缸为E、G两种压力极。
E极适用于,6.3MPa,16Mpa压力范围的液压缸(简称E级油缸)。
G极适用于,缸) 16MPa,25MPa压力范围的液压缸(简称G极油2.密封:E级油缸采用结构简单,耐磨性好的YX型聚胺脂密封圈和适用范围宽的YX型橡胶密封圈。
G极油缸采用耐高压,密封可靠的V型组合密封圈。
3.防压:本液压缸均采用聚胺脂或丁腈橡胶无骨架式防尘圈。
4.适用介质:液压油、机械油、乳化液。
(不适用于磷酸脂)oo5.适用温度:-40C,+180C。
6.结构:本标准缸共有17种缸径(40、50、63、80、90、100、110、125、140、150、160、180、200、220、250、280、320),按两种速比(1.46、2)组成34种规格;分成带间隙缓冲两种结构。
上述34种规格组成68个品种,便于用户任意选用。
7.安装连接:符合国际标准ISO6020/1- 1981中系列液压缸安装连接尺寸。
不同缸径均有基本型,前、后长方法兰,前、后方法兰,前、后圆法兰,前、中、后销轴,头部单耳环;轴向、径向脚架共13种安装型式(详见型号说明及附表)。
除轴向脚架型外,安装连接尺寸均符合ISO6020/1-1981。
杆端螺纹亦符合GB2350-80规定。
1.型号说明中凡标有?号的目前暂按非标准处理。
2.压力分级E16MPa可适用6.3MPa,16MPa之间使用者只需填写E即可。
3.安装连接形式除中间销轴需在型号上注明1的具体尺寸外,其余按表上符号填写即可,外连尺寸请参考表5,17。
4.如需要间隙缓冲请填写H符号,如果不填H符号则接无缓冲交货。
5.行程请按行程系列表4中的分档填写。
用户也可以自行确定行程。
6.对液压缸的工作介质、适用温度、试验、外表涂漆、包装等有特殊要求者务请注明,末注明特殊要求者一律按标准交替。
A –Seat/Mating RingB –Face/PrimaryC –Sleeve D–SegmentedE –Distributed FlushsTemperature:-40°C to 260°C/-40°F to 500°F sPressure:Up to 69 bar g/1000 psig max.sSpeed:Up to 25 m/s/5000 fpmPerformance Capabilitiess Cartridge Seal Designs Computer Optimized Low Emission Seal Faces sAPI 682 Test QualificationType 1648/2648/3648 seals evolved from the successful,proven John Crane Type 48 design, the preferred choice for safe, reliable, single, and dual unpressurized and pressurized seal arrangements in petroleum services.These dependable, engineered mechanical seals were developed specifically to attain MACT (MaximumAchievable Controlled Technology) compliance in hydro-carbons and other volatile organic compounds (VOCs).Type 1648 single seals typically control emissions to less than 200 ppm.sFully meets the needs of the oil and gas industry for hydrocarbon and other services as defined by API 682for Type A seal duties. This includes: heavy and light hydrocarbons, lubricating liquids, aqueous solutions,chemicals, and some acids.sIndustrial applications involved in the processing of VOCs and similar hazardous products.Type 3648 - API Type A Arrangement 3 - Dual Pressurized CartridgeThe primary default seal selection per API 682 is the Type A, multiple-spring pusher seal that is supplied in single, dual unpressurized and dual pressurized arrange-ments.The John Crane Type 48 is the seal on which our API 682 offering is based. The Type 48 family includes the following seals:s Type 48LPBalanced pusher seal with plain-face design for lower pressure applications. Used as a single inboard seal on dual unpressurized arrangements and as an outboard seal on either dual pressurized or unpressurized arrangements. s Type 48MPBalanced pusher seal with plain-face design that incorpo-rates a hammerhead to increase primary ring stiffness for medium to high pressure applications. Used as a single inboard seal on dual unpressurized arrangements and as an outboard seal on either dual pressurized or unpressur-ized arrangements.s Type 48HPBalanced pusher seal with hammerhead geometry that incorporates hydropads to increase face lubrication stiffness for high pressure applications. Used as a single inboard seal on dual unpressurized arrangements, and occasionally as an outboard seal on dual pressurized arrangements.s Type 48RPDouble balanced pusher seal primarily designed forID pressure applications. Commonly referred to as a reverse pressure design. Used as an inboard seal on dual pressurized arrangements and occasionally as an inboard seal on dual unpressurized arrangements.s Type S48Shorter balanced seal designed for OD pressures only. Used as an outboard seal on either dual unpressurized or dual pressurized arrangements.Selection Considerations MultiplierFactorSealed Fluid Below 80˚C/175˚F x 1.00 Temperature Above 80˚C to 125˚C/175˚F to 250˚F x 0.90Above 125˚C to 180˚C/250˚F to 350˚F x 0.80Above 180˚C/350˚F x 0.65 Materials Tungsten Carbide vs. Silicon Carbide x 0.50Example for Determining Pressure Rating Limits: Seal:75mm/3"Diameter Type 48LP Product:Lube OilTemperature:82˚C/180˚FSpeed:3600 rpmUsing the Type 48LP Pressure Ratings Limit graph, the pressure limit is 37 bar g/535 psig. From the Multiplier Factors chart, apply the appropriate value, in this case 0.90. For this service condition, the maximum operating pressure is:535 psig x 0.90 = 33 bar g/481 psigNotes:1.The above temperature derating factors apply to seals with Carbon primary rings only, not hard face vs. hard face combinations.2.The temperatures noted are product temperatures for single seals or the expected average temperature of the product and buffer/barrier fluid for dual seals.TYPE 1648/2648/3648API 682 Type A Pusher SealsCarbon vs. Reaction Bonded Silicon Carbide(Other application-specific limits may apply. Contact John Crane Engineering for application assistance.)TYPE 1648/2648/3648API 682 Type A Pusher Seals1,5001,3001,1009007005007060408090100505.51.0 1.52.0 2.53.53.0OD Pressure Limits for LP, MP, HP, RP, S48Carbon vs. Silicon CarbideTungsten vs. Silicon Carbide48RP ID Pressure Carbon vs. Silicon Carbide4.05.04.5255075125100Pressure (psig)Pressure (bar g)(inches)Seal Size(mm)NOTE:The hydrostatic and static limits are based upon O-ring extrusion limits, not component stresses.Therefore, hydrostatic and static limits are the same.850800750700650600585654525048464442Mating Ring SizePressure (psig)Pressure (bar g)(inches)(mm)The L-shaped mating ring used for dual seal arrangements is designed to be hydraulically balanced when used with the proper seal size. The pressure limit of the mating ring should be considered along with the seal head pressure limit when selecting dual seal arrangements.The pressure limit with OD pressure is 57.2 bar g/830 psig for Silicon Carbide. This chart shows the ID pressure limit for the Silicon Carbide mating ring.TYPE 1648/2648/3648API 682 Type A Pusher SealsExcessive runout will have a detrimental effect on sealperformance in the form of component wear or excessiveleakage. API 682 limits runout as follows:s Centering of the seal is to be by a register fit. Theregister fit surface shall be concentric to the shaft andhave a total indicated runout (TIR) of not more than125 micrometers/0.005".s Squareness of the seal chamber face to the shaft shallnot exceed 0.0005" per inch of seal chamber bore(15 micrometers/3cm).s Runout of the sleeve outer diameter to the inner diametershall be 0.001"/25 micrometers TIR.s Shaft-to-sleeve diametrical clearance shall be to ToleranceGrade G7/h6.North and Latin AmericasMorton Grove, Illinois USATel: 1-847-967-2400Fax: 1-847-967-39151-800-SEALINGEurope,Middle East,AfricaSlough, UKTel: 44-1753-224000Fax: 44-1753-224224Asia PacificSingaporeTel: 65-222-9161Fax: 65-223-5035For your nearest John Crane facility, please contact one of the locations above.If the products featured will be used in a potentially dangerous and/or hazardous process, your John Crane representative should be consulted prior to their selection and use.In the interest of continuous development, John Crane Companies reserve the right to alter designs and specifications without prior notice. It is dangerous to smoke while handling products made from PTFE. Old and new PTFE products must not be incinerated.©1999 John Crane Print 5/ ISO Certified S-1648/2648/3648 SEAL COMPONENTS MATERIALSDescription Standard OptionsFace/Primary Ring Antimony Carbon Nickel Binder Tungsten CarbideAlpha Sintered Silicon CarbideResin CarbonSeat/Mating Ring Reaction Bonded Alpha Sintered Silicon CarbideSilicon CarbideRetainer316 Stainless Steel—SpringDiscSnap ScrewSet ScrewSleeveCollarSegmented BushingGland PlateAuxiliary GlandSpring Alloy C-276316 Stainless Steel(UNS N10276)(Single Spring Only)O-Ring Fluoroelastomer Amine-Resistant PerfluoroelastomerLow Temp Buna-NPerfluoroelastomer。
Engineering Your SuccessParker’s Truck Hydraulics Center (THC) offers all the Parker products you need, engineered into a system solution to give you optimum performance for your work truck. Our THC’s have it all: on-site service bays and complete hydraulic, pneumatic components and system coverage. Whether it’s a component repair, replacement, or a complete system design and installation, Parker THC is the expert team you can rely on to keep your truck on the road.Table of ContentsmarketpageAerial Lift 3Agriculture Tow & Recovery 633Bulk Transport Oil and Gas 935Dump Truck & Trailer Forestry and Line 1338Refuse Truck Mounted Cranes 2142Snow & Ice Pumper Cleaner 284624V20 Build Program 48VA20 Build Program 50VA35 Build Program 52Racor & Tire Saver 54Diagnostic Test Equipment55CylindersF = PXAP = F/AA = F/PArea of a Circle = Dia. Sq. X .7854PumpsGPM = [RPM X CID] /231 x Eff CID = [GPM X 231] / RPMT = [CID X PSI] /75.36T = [HP X 5252] / RPMHP = [T X RPM] 5252MotorsRPM = [GPM X 231] / CIR CIR =[GPM X 231] / RPM T = [CIR X PSI] / 75.36Helpful FormulasConversionsCCM = CID X 16.39CID = CCM X .06102PSI = Bar X 14.5Bar = PSI /14.51 Bar = 14.5 PSI Glossary of TermsF = ForceA = AreaP = Pressure Eff. = Efficency HP = Horse Power GPM = Gallons Per Minute PSI = Pressure Per Sq. Inch RPM = RevolutionsCIR = Cubic Inches Displaced231 = Cubic Inches Displaced per revolution3T H C P r o d u c t C a t a l o gAerial LiftPTO’sGear PumpsLSHT Motors4Variable Volume Piston PumpsHPD Model NumberP1018PS08SRM5AL00E000PB00Aerial LiftHydraulic Valves5T H C P r oAir PreparationViking ExtremeDirect Air 2Prep Air 2PneumaticsAerial Lift6AgriculturePTO’sGear PumpsHydraulic Valves7T H C P r o d u c t C a t a l o gSpreader ValvesTanksAccessory ValvesDouble SelectorPriority Flow Control8PneumaticsAir PreparationViking Extreme42 SeriesAgriculture9T H C P r o d u c t C a t a l ogBulk TransportPTO’sGear Pump10Hydraulic ValvesHydraulic MotorsInline ReliefBulk Transport11T H C P r o PneumaticsAir PreparationViking Extreme42 SeriesDirect Air 2Bulk Transport12Direct Air 4Load TamerValve Air Manual SpoolsPrep Air 2Bulk Transport13T H C P r o d u c t C a t a l o gDump Truck TrailerPTO’s14Gear PumpDump Truck Trailer15T H C P r o d u c t CGear Pump AccessoriesIn Cab ControlsDump Truck TrailerDin Flange Pumps for Mack & Volvo16TelescopicCylindersDump Truck & Dump TrailerDump Truck Trailer17T H C P r o d u c t C a t a lHydraulic TanksDump Truck TrailerTelescopic CylindersDump Truck & Dump Trailer18PneumaticsAir PreparationViking ExtremeFiltrationHydraulic ValvesDump Truck Trailer19T H C P r o d u c t C aDirect Air 4Load TamerValve Air Manual SpoolsPrep Air 2Direct Air 2Dump Truck Trailer20Refuse TruckPTO’s21T H C P r o d u c t C a t a l o gGear Pump22Vane PumpsRefuse Truck23T H C P r o d u c t C a t a lTelescopic CylindersRefuse Truck24Refuse TruckTelescopic Cylinders25T H C P r o d u c t Hydraulic Valves VA35V20FiltrationRefuse Truck26PneumaticsAir PreparationViking ExtremeDirect Air 2Direct Air 4Refuse Truck27T H C P r o d u c tLoad TamerValve Air Manual SpoolsPrep Air 2Refuse Truck28Snow and Ice TruckPTO’sGear PumpHydraulic Motors29T H C P r o d u c t C a t a l o gSpreader ValvesPiston PumpNote: All Piston Pumps listed above are end ported and turn CW Rotation to change the rotation to CCW change the R to a code L, and to change the end ports to side ports change the E to a code S.30Electronic DisplayMDL2 ModelDriversAX2 ModelElectronic ControllersTOC 2 ModelSnow and Ice Truck31T H C P r o d u c t C a t a l o gElectronic ProcessorXCPHydraulic ValvesTanksFiltrationSnow and Ice Truck32Tow and RecoveryPTO’sGear Pumps33T H C P r o d u c t C a t a l ogLSHT MotorsHydraulic ValvesFiltration Spin On34PneumaticsAir PreparationViking ExtremeDirect Air 2Load TamerTow and Recovery35T H C P r o d u c t C a t a l o gOil/Gas/Water Drilling TrucksPTO’sGear PumpHydraulic Valves36Combo Valve KitTelescopic CylindersFiltrationOil/Gas/Water Drilling Trucks37T H C P r o d u c tPrep Air 2PneumaticsAir PreparationViking ExtremeDirect Air 2Direct Air 4Oil/Gas/Water Drilling Trucks38Forestry & LinePTO’s39T H C P r o d u c t C a t a l o gGear Pumps40LSHT MotorsHydraulic ValvesForestry & Line41T H C P r o d u c t C a t a lPneumaticsAir PreparationViking ExtremeDirect Air 2Direct Air 4Forestry & LineFiltration Spin On42Truck Mounted CranesPTO’s43T H C P r o d u c t C a t a l ogGear and Piston Pumps44LSHT MotorsHydraulic ValvesFiltration Spin OnTruck Mounted Cranes45T H C P r o dLoad TamerValve Air Manual SpoolsPrep Air 2PneumaticsAir PreparationViking ExtremeTruck Mounted Cranes46Pumper CleanerPTO’sGear Pumps and Motors Hydraulic ValvesPiston Pumps47T H C P r o d u c t C a t a l o gLSHT MotorsHydraulic FiltrationFiltration Spin On48V20 Build ProgramUp to 25 GPMInlet & Outlet Size SAE 12Work Port Size SAE 10。
System Solutions ForThe Steel IndustryY our Resource For Motion Control Components, Systems and SolutionsThe Steel Industry: A FocusParker means components, systems and partnerships that workParker is committed to offeringthe steel industry the mostcomprehensive array of motioncontrol products and technologies.We are continuously evaluatingindustry requirements anddeveloping new products tomeet current and futuresteel industry needs.Industry LeaderParker is a leading supplier ofcomponents and systems tosteel manufacturers worldwide.The breadth and depth of ourproduct lines allow us to offerthe steel industry the appropriatehardware to meet any applicationor requirement. And, ourengineers will help specifyand evaluate the productsyou need for your specific steelmanufacturing needs. Parkeris the name to count on for qualityproducts, on-time delivery andcomprehensive technical support.tiseEngineering ExperEngineering ExpertiseParker offers unparalleledtechnical assistance andsupport. Our dedicated salesand application engineers willwork with you throughout thedesign process to optimizeproduct value. We don’t justwant you to use our componentsand systems - we want youto use them effectively.V endor ReductionMany suppliers talk about singlesourcing, but no one is betterequipped to provide it thanParker. We can supply all ofthe hydraulic, pneumatic andelectromechanical componentsyour application requires. Thissingle sourcing allows you tosave on time and money. Justone more reason to buy Parker.Instrumentation GroupAerospace GroupSeal GroupClimate & Industrial Controls GroupFluid Connectors GroupAutomation GroupHydraulics GroupFiltration GroupProducts For Any ApplicationParker makes over 500,000 parts to meet your system needsParker — Providing The Steel Industry With Complete System Solutions.Everyone knows Parker is the leading motion controlcomponent supplier to the steel industry. Nowwe’re going one stepfurther…by putting our70 years of applicationengineering expertise to work for you as the single source solution for yourentire motion controlsystem. Y ou know the ‘Steel Industry’, and we know ‘Motion Control’.Our sales engineers will work with your designers to bring together all of the hydraulic, pneumatic,and electromechanical components necessary to make the ideal system for you.Proportional Control Directional ControlInsert Cartridge ValvesElectrohydraulic Working with Parker brings many benefits,including quality products, system integrity, worldwide distribution, extensive field support, unequaled customer service,as well as shortened product lead times,simplified ordering and more efficient shipping.But most importantly,with the assistance of Parker’s application engineers, you can be sure that the ‘Motion Control’ capability of your new system willmeet and exceed both your specifications...and your expectations.Pneumatic TubingStandard products available in Polyethylene, polypropylene,nylon, polyurethane, Teflon ®,and vinyl. Available in a variety of colors with thermoplastic and brass fitting connections.1/8" through 2 1/2" hydraulicand pneumatic quickcouplings are available insingle and double shut-off.Available in steel, stainlesssteel and brass.Vacuum to 60,000 psi (414MPa). Sizes from 1/8 in. to 2in. (3mm to 51mm) I.D. in bothrubber and thermoplastic.Steel braided or spiralreinforcements.Hydraulic and pneumatic tie-rod design provides torque upto 600,000 lb-in. and rotationto 720°. PolyPak piston sealsand wearbands eliminateleakage and cylinder scoring.Wide variety of tube andhose fittings and adapters areavailable, including flare, bite-type and O-ring face sealfittings. Materials includesteel, stainless steeland brass.Non-tie rod design providesdurability in torque sizes to50,000,000 lb-in. Rotationsup to 360°. Large diametertapered roller bearings supportthe pinion. 3000 psi workingpressure and 6000 psi proof.High quality CPI and A-LokTube Fittings for the mostdemanding process controland instrumentationapplications. Availablein a variety of materials.Skinner, Lucifer and GoldRing™ solenoid valvescontrol fluids and gases;Sinclair Collins valvescontrol high pressure waterhydraulics, descaling,and steam.Manual, pneumatically andelectrically actuated ballvalves, check valves, andmanifold configured valvesare among those available.Prolong component life.Proper filtration use doubles warranty on all Parker pneumatic products in the system.High starting torque, high volumetric efficiency and long life. Pressures to 4000 psi intermittent,torques to 15,000 lb-in and displacements to 67.3 in 3 par revolution.Maximum operating speeds to 6000 rpm, pressures to 3600 psi and displacements to 250 cc per revolution.Reversible motors with external case drainsare standard.High flow, fast response air valves with W earC ompensating S ystem (WCS )feature ISO standard and plug-in style mounting for simplified installation and reduced wear.Serial interfacecommunications that allow banks of directional control valves to be driven from a PC or PLC. Hydraulic and pneumatic styles available.Bladder and Pistonaccumulators, Gas Bottles,and ParVent HydraulicResevoir Isolators available.Piston pumps for water glycol,synthetics and mineral oils.Displacements to 250 cc per revolution and 5000 psi continuous. Full line of control options and cast iron housings for quiet durable operation.Gear, vane and piston designs, flows to 100 gpm and pressures to 3600 psi continuous. Fixed vane pumps are Vickersinterchangeable.Custom Cylinders48 inch bore, 40 foot strokes,pressures to 10,000 psi. Mill type, welded, threaded head,telescopic, and ram designs available. Feedback devices also available in all designs.Hydraulic & Pneumatic Tie Rod CylindersHeavy duty service with Industrial Tie Rod products.Bore sizes to 20 in., rod diameters to 10 in. Nominal pressures to 3000 psi in 16 standard mountings.Hydraulic & Mill Type CylindersHeavy duty 3000 psi Mill Cylinders. Bolted flange design in 6 mounting styles,to 22 inch bore and 10 in.rod diameters.Servo ActuatorsFully assembled and testedunits. Bore sizes from 2-10 inch,strokes to 180 inches with LDT feedback. Subplate mounts in NFPA D03, D05 and servo.Servo motors are also available with encoder feedback.For additional information, contactyour local sales engineer at 1-800-C-PARKER or visit us on the web at Premier Customer Service Initiatives... Field Sales TeamParker’s highly trained fieldsales force provides expertassistance in your productselection, working hand-in-hand with your local Parkerdistributor. These expertsare strategically locatedthroughout the worldto work with you onproduct application issues. Parker IntegrationNetwork (PIN)PIN is an alliance between a select group of independent systems engineering companies and the Parker family of motion control products and support team. These ‘System Integrators’ will work with you to establish a custom automated turnkey system. (/pin)Industry-Leading TechnicalSupport and TrainingThe Parker network of applicationspecialists, support professionalsand distributor personnelwill provide expert technicalassistance where and whenyou need it, as well as trainingin motion control technology.Worldwide DistributionNetworkWith over 7,500 distributors,our distribution network is thestrongest in the industry, providingcomprehensive technical supportand after-the-sale service.Printed and ElectronicSales LiteratureParker offers the mostcomprehensive selection of productand technical information in printedform, as well as electronic versionson CD-ROM and our web page.inPHorminPHorm is Parker’s productselection software that helps youchoose the correct components foryour application, saving you timeand making selecting, specifyingand ordering easier.We’re Where You Are...Worldwide.•T o order products, CD’s and other product information call 1-800-C-PARKER.•T o contact your local sales engineer, call 1-800-C-PARKER.•Visit us on the web at Bulletin No. 01164.5M 6/99 FPParker Hannifin Corporation6035 Parkland Blvd.Cleveland, Ohio 44124Phone: (216) 896-3000Fax: (216) 896-4031。
Filtration Housings For food and beverage applications4-5 Introduction to Parker 6-7 Dedicated filtration range 8-9Housing quick reference10-11 PHP single and multi 12-13 PHB multi 14-15 PHB demi 16-17 PHB single 18-19 PHF demi 20-21 PHI single22-23 PHV single and multi 24-25 PHW single 26-27 PHW multi 28-29 Heating equipment 30-31Related productsContentsParker’s filter housing range is designed both to meetinternational industry standards and specific customer application requirements. With over 50 years’ experience designing and fabricating major systems for the food and beverage industry, a combination of practical experience with design and manufacturing excellence have gained Parker a reputation for supplying high quality products.As a customer of Parker you have access to highly skilled engineers, trained to meet your exact product and service requirements at the highest possible standards.Additional services include: Project management Process system design Global support Operator trainingDedicated technical team Quality management systemsVessels are built to meet industry standardsPED (2014/68/EU)ATEX (2014/34/EU)All Parker vessels adhere to manufacturing best practiceISO9001ISO14001Dedicated filtration rangeAs well as supplying vessels, Parker supply automated filtration systems and manufacture a range of microfiltration cartridges for liquid and gas applications.Since 1963, Parker have continually innovated to support food and beverage producers and packagers worldwide. Product ranges have been designed to deliver optimum operational performance and maintain key commitments to protecting product quality, reducing processing costs and providing specialist support.Dedicated products are available for various beverage industries including;Supported by innovative products, state-of-the-art technicalfacilities and a specialized international team, Parker’s capability is based on understanding the specific needs of your business and providing a total solution.BrewingWine making DairyBottled water IngredientsAir / Gas Liquid VentIndustrial Liquid / Pre-filtrationT-Port T-Port Open T-Port In-line In-line T-Port SteppedAir / CO 2 / Nitrogen filtrationTop pressure / blanketing to water , beer , wine or dairy Compressed air to blow dry clean bottles or cans Industrial fermentation Steam (up to 3.5 Bar)Water , beer , wineClarification, stabilisation and sterilisation to remove particles or microorganisms.Industrial or food and beverage tank vents Vent to atmosphere Water treatment Prefiltration ClarificationApplicationsThe PHP housing range is specifically designed for liquid applications in:BeerWineBottled WaterSuitable for use with PED Group 2 liquid and gas.AvailabilityThe PHP liquid filter housing range is available for 1 to 30 round cartridges. They will accept Parker’s full range of C-Style (226) or D-Style (222) liquid filter cartridges of nominal length 10¨ to 40¨.MaterialsApplicationsThe PHB multi range is specifically designed for high flow rate gas filtration applications in:BeerWineBottled WaterDairyIndustrial FermentationSuitable for use with PED Group 2 gas.AvailabilityThe PHB multi gas filter housing is availablein sizes from 3 up to 32 round. These housingswill accept Parker’s full range of C-Style (226) gas filter cartridges of nominal lengths 10”, 20” and 30”.ApplicationsThe PHB filter housing range is specifically designed for gas filtration applications in:BeerWineBottled WaterDairySuitable for use with PED Group 1 & 2 Gas. AvailabilityThe PHB Demi gas filter housing range is available for Parker’s full range of Trueseal (126) gas filter cartridges of nominal lengths 2.5” and 5”.MaterialsAISI 316L grade stainless steel is used for all wettedApplicationsThe PHB filter housing range is specifically designed for gas filtration applications in:BeerWineBottled WaterDairySuitable for use with PED Group 2 Gas.AvailabilityThe PHB gas filter housing range is available for Parker’s full range of C-Style (226) gas filter cartridges of nominal lengths 5” to 30”.MaterialsApplicationsThe PHF filter housing range is specifically designed for low flow rate liquid and gas applications in:BeerWineBottled WaterDairySuitable for use with PED Group 1 and 2 liquids and gas.AvailabilityThe PHF filter housing range is available in a single round, demi format. These housings will accept Parker’s full range of Z-Style (116) liquid and gas filter cartridges of nominal lengths 2.5” and 5”.ApplicationsThe PHI filter housing range is specifically designed for in-line liquid and gas applications in:BeerWineBottled WaterDairySuitable for use with PED Group 2 liquid and gas.AvailabilityThe PHI filter housing range will accept Parker’s full range of C-Style (226) liquid and gas filter cartridges, of nominal lengths 5¨ to 40¨.MaterialsApplicationsThe PHV vent filter housing range is specifically designed for food and beverage applications that require filtration of tank air to atmosphere in:BeerWineBottled WaterDairyAvailabilityThe PHV vent filter housings are available as single and multi-round for 1, 3, 5, 8 and 12 filter cartridges. The series will accept Parker’s full range of C-Style (226) filter cartridges of nominal lengths 10¨, 20¨ and 30¨.ApplicationsThe PHW single round filter housing range is specifically designed for liquid pre-filtration applications in:BeerWineBottled WaterThe range is suitable for use with PED Group 1 and 2 liquids, and PED Group 2 gas.AvailabilityThe PHW single cartridge housing range can accept Parker’s full range of C-Style (226), D-Style (222) and DOE cartridges of nominal length 10¨ to 40¨.ApplicationsThe PHW multi round filter housing is specifically designed for liquid pre-filtration applications in:BeerWineBottled WaterSuitable for use with PED Group 2 liquids.AvailabilityThe PHW multi round housing range is available for 3, 5 or 8 filter cartridges. This housing is available to accept Parker’s full range of C-Style (226), D-Style (222) and DOE liquid filter cartridges of nominal lengths 20”, 30” and 40”.HousingsStandard Housing - Ordering Information * Single round onlySilicone foam rubber heating jacket with internally meshed heating wires. Open longitudinal slit down the length to slide over a housing.Five standard sizes, A (Demi), K, 10¨, 20¨, 30¨.230 (240) volts supply, not grounded.Protection rating: IP65.Design standards: EN 60519-1 and 2.Temperature sensor, PT100, built-in with 1m cable. ISOPAD temperature controller.On / Off switch.230 V live and neutral.Maximum ambient temperature 55 °C (131 °F).Set temperature display: 8mm red LED.Actual temperature display: 10mm green LED.Protection rating: IP65.Design standards: EN61010-1.1m power cable. (available as accessory kit)Volt free output for an alarm.Comprehensive installation, operation and maintenanceinstructions (IOMI).PID Control- SSR Output (12V)- Alarm relay (2.4A)The heating jacket offers support to Demi A,K to 30¨housings including:PHBPHIPHV*Dim ‘A’Dim ‘B’Dim ‘C’Signal out7 pin hirschmann male1m black cablePower In4 pin hirschmann female1m brown/red cable200188121892ON / OFFSwitchAlarm connectionHirschmann 7 pin male with capHirschmann 4 PIN male - power in (to controller)Hirschmann 7 PIN female - PT100 signal inHirschmann 4 PIN female - Power out (to heater)Part Code Part Number Housing Size Supply Voltage ControllerXBHSI05-230V6395031455” Demi230V IncludedXBHSI05KN-230V6395043995¨230V IncludedXBHSI10N-230V63950440010¨230V IncludedXBHSI20N-230V63950440120¨230V IncludedXBHSI10N-230V-NC63950440310¨230V Not IncludedXBHSI20N-230V-NC63950440420¨230V Not IncludedAccessoriesPart Code Part Number DescriptionXBHXT2M639503496 2 meter power and signal cable extensionXBHPS1M-PSEU639503199Power cable with European plugXBHPS1M-PSUK639503200Power cable with UK plugXBHPS1M-PS639503640Power cable with no plugKit excludes mains power cable.Together with Agidens Process Automation, Parker can One prefilter stage, one final filter stageFlow range: 40-100hl/hr One prefilter stage, two final filters (duplex)Flow range: 100-300l/hr Two prefilters (duplex), four final filters (duplex)Flow range: 300-600l/hr PREPOR NGHIGH FLOW TETPOR IIBEVPOR BRTURBOSEPBEVPOR PHValairdata 3BEVPOR PSBevcheck Automated SystemsCSM 11CSM 12CSM 24PREPOR PPASEPT-XHIGH FLOW BIO-XBEVPOR MHBevcheck PlusParker Hannifin Manufacturing Ltd Bioscience Filtration - EMEA Durham Road, Birtley, Co. DurhamDH3 2SF, England。
Catalog HY15-3502/USLogic Elements ContentsParker Hannifin CorporationSERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO.LPM/GPM BAR/PSIPOPPET TYPE10SLC1-A.........C10-3S........Normally Closed, Pilot to Close.......................57/15......240/3500......................LE7 16SLC1-A.........C16-3S........Normally Closed, Pilot to Close.....................189/50......240/3500......................LE8 20SLC1-A.........C20-3S........Normally Closed, Pilot to Close.....................303/80......240/3500......................LE916SLC1-C.........C16-3S........Normally Closed, Vent to Open.....................189/50......240/3500....................LE10SPOOL TYPE10SLC2-A.........C10-3S........Normally Closed, Pilot to Close.......................57/15......240/3500....................LE11 16SLC2-A.........C16-3S........Normally Closed, Pilot to Close.....................189/50......240/3500....................LE12 20SLC2-A.........C20-3S........Normally Closed, Pilot to Close.....................303/80......240/3500....................LE13R04E3...............C10-3S........Normally Closed, Pilot to Close.....................170/45......420/6000....................LE14 R06E3...............C16-3S........Normally Closed, Pilot to Close..................400/106......420/6000....................LE15 R08E3...............C20-3S........Normally Closed, Pilot to Close..................500/132......420/6000....................LE1610SLC2-B.........C10-3S........Normally Closed, Vent to Open.......................57/15......240/3500....................LE17 16SLC2-B.........C16-3S........Normally Closed, Vent to Open.....................189/50......240/3500....................LE18 20SLC2-B.........C20-3S........Normally Closed, Vent to Open.....................303/80......240/3500....................LE19R04F3...............C10-3S........Normally Closed, Vent to Open.....................170/45......420/6000....................LE20 R06F3...............C16-3S........Normally Closed, Vent to Open..................400/106......420/6000....................LE21 R08F3...............C20-3S........Normally Closed, Vent to Open..................500/132......420/6000....................LE2210SLC3-A.........C10-3S........Normally Open, Vent to Close.........................57/15......240/3500....................LE23 16SLC3-A.........C16-3S........Normally Open, Vent to Close.......................189/50......240/3500....................LE24R04H3..............C10-3S........Normally Open, Vent to Close.........................57/15......420/6000....................LE25 R06H3..............C16-3S........Normally Open, Vent to Close.......................160/42......420/6000....................LE2610SLC3-B.........C10-3S........Normally Open, Vent to Close.........................57/15......240/3500....................LE27 16SLC3-B.........C16-3S........Normally Open, Vent to Close.......................189/50......240/3500....................LE28R04G3..............C10-3S........Normally Open, Vent to Close.........................57/15......420/6000....................LE29 R06G3..............C16-3S........Normally Open, Vent to Close.......................160/42......420/6000....................LE30LE1Logic ElementsCatalog HY15-3502/USTechnical TipsParker Hannifin CorporationCatalog HY15-3502/USLogic Elements Technical TipsParker Hannifin CorporationLE2LE3Logic ElementsCatalog HY15-3502/USTechnical TipsParker Hannifin CorporationCatalog HY15-3502/USLogic Elements Technical TipsParker Hannifin CorporationLE4LE5Logic ElementsCatalog HY15-3502/USTechnical TipsParker Hannifin CorporationDIRECTIONAL CONTROL EXAMPLESTHREE-WAY BRIDGE CIRCUITS Circuit 1, with **SLC1A poppet logic element.Circuit 2, with **SLC2A/R0*E3spool logic element.Circuit 3, with **SLC2A/R0*E3spool logic element.NOTE: Pilot pressure must exceed load pressure in order for valve to close.FOUR-WAY BRIDGE CIRCUITSCircuit 1, with **SLC1A poppet logic elements.Circuit 2, with **SLC2A/R0*E3 spool logic elements.Required Flow PathPilot Pressure Applied To PA PB 123Available From CircuitNONOXXYESNO X X XRequired Flow PathPilot Pressure Applied To PA PB 123Available From CircuitNOYESXXNO YES X XPilot Pressure Applied To P1P2P3P4P5Required Flow PathPilot Pressure Applied To P1P2P3P4P5Required Flow PathPilot Pressure Applied To P1P2P3P4P5Required Flow PathYES YES YES YES YESNO NO NO NO NOYES YESNO NO NONONO YES YES NOYES YES YES YESNOYESNONOYES YESNO YES YES NO YESYES YES NO YES YESNO YES YES YES YESNO YES NO YES YESYESNOYESNOYESYES YES YES NO YESYES NO YES YES YESP APBBACBAP APB CPB BP A ACABC ABCABC ABCPP5TP1P2A P3BP4P2A P1PP5TP4BP3ABP T ABPTABP T ABPTABP T ABP T ABP T ABP T ABP T ABPTABP T ABP T ABP T NOTE: Pilot pressure must exceed load pressure in order for valve to close.Catalog HY15-3502/USLogic Elements Technical TipsParker Hannifin CorporationLE6LE7Catalog HY15-3502/USPoppet Type Logic Valve Series 10SLC1-AParker Hannifin CorporationTechnical Information(3)Poppet Type Logic ValveSeries 16SLC1-A Catalog HY15-3502/USParker Hannifin CorporationTechnical Information(3)(2)LE8LE9Catalog HY15-3502/USPoppet Type Logic Valve Series 20SLC1-AParker Hannifin CorporationTechnical Information(1)(3)(2)Poppet Type Logic ValveSeries 16SLC1-C Catalog HY15-3502/USParker Hannifin CorporationTechnical Information(3)(2)LE10LE11Catalog HY15-3502/USSpool Type Logic Valve Series 10SLC2-AParker Hannifin CorporationTechnical InformationSpool Type Logic ValveSeries 16SLC2-A Catalog HY15-3502/USParker Hannifin CorporationTechnical Information(1)(3) (2)LE12LE13Catalog HY15-3502/USSpool Type Logic Valve Series 20SLC2-AParker Hannifin CorporationTechnical InformationSpool Type Logic ValveSeries R04E3Catalog HY15-3502/USParker Hannifin CorporationTechnical InformationLE14LE15Catalog HY15-3502/USSpool Type Logic Valve Series R06E3Parker Hannifin CorporationTechnical InformationSpool Type Logic ValveSeries R08E3Catalog HY15-3502/USParker Hannifin CorporationTechnical InformationLE16LE17Catalog HY15-3502/USSpool Type Logic Valve Series 10SLC2-BParker Hannifin CorporationTechnical Information(1)(3) (2)LE18Parker Hannifin CorporationLE19Parker Hannifin CorporationSeries R04F3Parker Hannifin CorporationTechnical InformationLE20LE21Parker Hannifin CorporationSeries R08F3Parker Hannifin CorporationTechnical InformationLE22LE23Parker Hannifin CorporationSeries 16SLC3-AParker Hannifin CorporationTechnical Information(2)(3) (1)LE24LE25Parker Hannifin CorporationSeries R06H3Parker Hannifin CorporationTechnical InformationLE26LE27Parker Hannifin CorporationLE28Series 16SLC3-BParker Hannifin CorporationTechnical Information (2)(3)(1)LE29Parker Hannifin CorporationLE30Spool Type Logic Valve Series R06G3Catalog HY15-3502/USParker Hannifin CorporationHydraulic Cartridge SystemsTechnical Information。
冶金行业提供传动控制元件、系统及解决方案聚焦钢铁行业对外开放及国外直接投资以来,最早成立的三家外国合资企业之一。
在中国拥有2000多条产品线,产品涵盖50多个市场,为企业提供航空航天,环境控制,机电,过滤,流体与气体处理,液压,气动,过程控制,密封与屏蔽九大技术解决方案和服务。
产品应用及解决方案主要涉及重型商用车、风力发电、船舶制造、海洋勘探、钢铁、工程机械、高速铁路和工厂自动化等。
派克汉尼汾中国总部设在上海,在中国设有15个生产基地及9个销售办事处,在华已经拥有3000多名员工。
聚焦钢铁行业派克提供切实有效的元件及系统解决方案,并与钢铁制造商建立了广泛的合作关系。
致力为钢铁行业提供完善的传动控制产品解决方案,我们不断评估行业需要,开发新产品,以符合钢铁行业当前及未来的需求。
行业先行者作为一家为钢铁制造商提供元件与系统解决方案的卓越供应商,我们的产品系列具有足够的宽度和深度,可为钢铁行业提供适合多种应用场合的产品。
我们的工程师可协助您选择并评估所需产品,以符合您特定的钢铁制造需要,凭借优质产品,准时交货和综合技术支持,值得您的信赖。
工程专长派克提供非常完善的技术协助与支持,在设计阶段,我们的销售及应用工程师与您共同努力,挖掘产品价值。
我们不仅希望您使用我们的元件和系统,更希望帮助您有效地使用这些产品。
产品专业性许多供应商在谈到自己的产品时都非常专业,但是在这方面派克做得更好。
我们提供液压、气动、流体连接件、过滤和密封等多种产品。
专业的产品使您更省时省钱,这是您选择派克的又一个理由。
0102/china液压产品在1780mm 热轧机液压系统的应用可为客户提供液压动力站,超大蓄能器组,以及定制液压油缸。
鉴于这些动力系统的工作压力变化比较大,所采用的液压泵均为PV-plus, 能有效提高系统工作的稳定性,大大降低轧机再咬钢时系统压力的冲击,同时减少生产线的故障率,降低液压系统维护保养时间。
液压元件在棒材轧线液压系统的应用基于棒材轧线连续性作业的特性,派克提供液压系统的设计、配置及采用的高品质元件,具备操作稳定、易于控制、高效及故障率低等特点,同时解决了客户对系统污染的忧虑,提供在线油液污染检测设备,进行全天候监控并自动预警,及时提醒操作人员进行保养和维护工作,减少系统故障。
BConforms to ISO 6020/2 (1991)For working pressures up to 210 barMetric Hydraulic Cylinders Series HMIVital Technologies for Motion and ControlParker Series HMIMetric Hydraulic CylindersAs the world leader in the design and manufacture of tie-rod cylinders, Parker Cylinder Division introduces the Parker Series HMI metric hydraulic cylinder. Parker’s HMI Series cylinders are designed to meet the requirements of ISO 6020/2 (1991), 160 Bar Compact Series. HMI Series cylinders may be used for working pressures up to 210 Bar.Parker HMI Series cylinders are the true world standard, available all over the globe from Parker’s worldwide manufacturing facilities. Whether you or yourmachine are in Europe, Asia,South America, Canada, Mexico, or the United States, you can rely on the engineering expertise, manufacturing experi-ence, and commitment to quality that you’ve come to expect from the Parker Cylinder Division.BFeatures, Specifications and MountingsParker Series HMIMetric Hydraulic CylindersSeries HMI Standard Features and Specifications• ISO 6020/2 mounting interchangeable • 12 standard mounting styles • Up to 3 rod sizes per bore• Wide range of mounting accessories• Up to 3 male and 3 female rod end threads per bore • Bore sizes – 25mm to 200mm• Strokes – available in any practical stroke length• Working pressure up to 210 bar • Piston rods – 12mm to 140mm • Single and Double rod designs • Cushions available at either end • Temperature Range – -20°C to 150°C depending on seal type• Seal types to suit a wide variety of operating environmentsAvailable Mountings and Where To Find ThemIn line with our policy of continuing product improvement, specifications in this catalog are subject to change.1Piston RodGland seal life is maximized by manufacturing piston rods from precision ground, high tensile carbon alloy steel, hard chrome plated and polished to 0.2µm max. Piston rods are induction case hardened to Rockwell C54 minimum before chrome plating, resulting in a dent-resistant surface.2Parker’s ‘Jewel’ GlandContinuous lubrication, and therefore longer gland life, are provided by the long bearing surface inboard of the primaryseal. The Jewel gland, complete with rod seals, can easily be removed without dismantling the cylinder, so servicing is quicker – and therefore more economical.3Rod SealsThe TS-2000 primary seal has a series of sealing edges which take over successively as pressure increases,providing efficient sealing under all operating conditions.On the return stroke the serrations act as a check valve,allow-ing the oil adhering to the rod to pass back into theDesign Features and Benefits1342568977 & 8Parker Series HMIMetric Hydraulic Cylinderscylinder.The double lip wiperseal acts as a secondary seal, trapping excess lubricating film in the chamber between the wiper and lip seals. Its outer lip prevents the ingress of dirt into the cylinder, extending the life of gland and seals.The TS-2000 is manufactured from an enhanced poly-urethane, giving efficient retention of pressurized fluid and long service life.4Cylinder BodyStrict quality control standards and precision manufacture ensure that all tubes meet rigid standards of straightness,roundness and surface finish. The steel tubing is surface finished to minimize internal friction and prolong seal life.5Cylinder Body SealsTo make sure that the cylinder body remains leaktight, even under pressure shock conditions, Parker utilizes pressure-energized body seals.6One-Piece PistonSide loading is resisted by the wide bearing surfaces of the pistons. A long thread engagement secures the piston to the piston rod and, as an added safety feature, pistons are secured by an anaerobic adhesive.7CushioningProgressive deceleration is available by using profiled cushions at the head and cap – see Section C for details.The head end cushion is self aligning, while the polished cap end spear is an integral part of the piston rod.8Floating Cushion Bushings and SleevesCloser tolerances – and therefore more effectivecushioning – are permitted by the use of a floating cushion sleeve at the head end of the cylinder, and a floatingcushion bushing at the cap end. A slotted cushion sleeve at the head end and the floating bronze cushion bushing in the cap, provide minimum fluid restriction at the start of the return stroke. This allows full pressure to be applied over the entire area of the piston, providing full power and fast cycle times.BDesign Features and Benefits9Cushion AdjustmentNeedle valves are provided at both ends of the cylinder for precise cushion adjustment. 63 mm bores and smaller contain cartridge cushion assembly shown below.Gland DrainsThe accumulation of fluid behind the gland wiperseal of long stroke cylinders, or cylinders with constant back pressure,can be relieved by specifying the option of a gland drain.A port between the wiperseal and primary seal allows fluid to be piped back to a reservoir. By fitting a transparent tube between the port and the reservoir, fluid loss from concealed or inaccessible cylinders can be monitored to provide an early indication of the need for gland servicing. Gland drainsare described in greater detail in Section C of this catalog.Parker Series HMIMetric Hydraulic CylindersAir BleedsAvailable as an option at both ends, the air bleeds arerecessed into the head and cap.Piston SealsParker’s B style piston is a single seal design whichincorporates two wear strips. This design provides smooth operation, long bearing life, and high load carrying capacity.Servo CylindersServo cylinders permit fine control of acceleration, velocity and position in applications where very low friction and an absence of stick-slip are required. They may be used in conjunction with integral or external transducers. Servo cylinders combine low friction piston and gland seals with specially selected tubes and rods. For low-friction appli-cations – consult factory.Seal ClassesTo accommodate the many types of fluids and the varying temperature ranges used in industry, Parker offers a range of rod gland, piston and body seals. These are described indetail in Section C of this catalog.Mounting StylesISO Cylinder Mounting Stylesand Where to Find ThemThe standard range of Parker Series HMI cylinders com-prises 12 ISO mounting styles, to suit the majority of applica-tions. General guidance for the selection of ISO cylinders is given below, with dimensional information about each mounting style shown on the following pages. Application-specific mounting information is shown in the mounting information section, Section C of this catalog.Extended Tie RodsCylinders with TB, TC and TD mountings are suitable for straight line force transfer applications, and are particularly useful where space is limited. For compression (push) appli-cations, cap end tie rod mountings are most appropriate; where the major load places the piston rod in tension (pull applications), head end mounting styles should be specified. Cylinders with tie rods extended at both ends may be attached to the machine member from either end, allowing the free end of the cylinder to support a bracket or switch. Flange Mounted CylindersThese cylinders are also suitable for use on straight line force transfer applications. Two flange mounting styles are available, offering either a head flange (JJ) or a cap flange (HH). Selection of the correct flange mounting style depends on whether the major force applied to the load will result in compression (push) or tension (pull) stresses on the piston rod. For compression-type applications, the cap mounting style is most appropriate; where the major load places the piston rod in tension, a head mounting should be specified. Foot Mounted CylindersStyle C, foot mounted cylinders do not absorb forces on their centerline. As a result, the application of force by the cylinder produces a moment which attempts to rotate the cylinder about its mounting bolts. It is important, therefore, that the cylinder should be firmly secured to the mounting surface and that the load should be effectively guided to avoid side loads being applied to rod gland and piston bearings. A thrust key modification may be specified to provide positive cylinder location.Pivot MountingsCylinders with pivot mountings, which absorb forces on their centerlines, should be used where the machine member to be moved travels in a curved path. Pivot mountings may be used for tension (pull) or compression (push) applications. Cylinders using a fixed clevis, styles BB and B, may be used if the curved path of the piston rod travel is in a single plane; for applications where the piston rod will travel in a path on either side of the true plane of motion, a spherical bearing mounting SB is recommended.Trunnion Mounted CylindersThese cylinders, styles D, DB and DD, are designed to absorb force on their centerlines. They are suitable for tension (pull) or compression (push) applications, and may be used where the machine member to be moved travels in a curved path in a single plane. Trunnion pins are designed for shear loads only and should be subjected to minimum bending stresses.TBHH Style CISO Style MS2CBBDB Parker Series HMIMetric Hydraulic CylindersBAll dimensions are in millimeters unless otherwise stated.Piston Rod End Dataand ThreadsParker Thread Style 9– Short Stroke Cylinders Style 9 (female) rod endsshould not be used on 160mm or 200mm bore cylinders with a stroke of 50mm or less.Parker Thread Styles 4 & 7The smallest diameter rod endthread for each bore size isdesignated Style 4 when sup-plied with a No.1 rod. When the same rod end thread issupplied with a No. 2 or No. 3rod, it is designated Style 7.25 & 32mm Bore Cylinders5mm extra height applies to port face at head end only.Parker Thread Styles 4 & 7– All Except JJ Mount Parker Thread Style 9 –All Except JJ MountParker Thread Styles 4 & 7– JJ MountParker Thread Style 9 –JJ MountParker Series HMIMetric Hydraulic CylindersAABBDDEEEF FTG J KB TG WF WH Y + StrokeBSP/G inchesPJZJ 4019M5x0.84011/410104025428.3251550531144724M6x14511/410104025533.2352560561285935M8x1633/810104538 6.541.7352562731537446M12x1.25751/2161645381052.3412567741599146M12x1.25901/2161645381064.34832718016811759M16x1.51153/4202050451382.75131779319013759M16x1.51303/4222250451396.957358210120317881M22x1.516512222585818125.957358611723221992M27x220512525585822154.9573286130245269115M30x22451-1/42525767624190.2573298165299Extended Tie Rod MountingsAll dimensions are in millimeters unless otherwise stated.1Head depth increased by 5mm to accommodate port on 25mm and 32mm bore cylinders – see page 111Dimensions – TB, TC & TD See also Rod End Dimensions, page 111Parker Series HMIMetric Hydraulic Cylinders25 32 40 50 63 80 100 125 160 200Bore φBFlange and Side Lugs Mountings1Head depth increased by 5mm to accommodate port on 25mm and 32mm bore cylinders, except Style JJ in port positons 2 and 4 – see page 111Dimensions – JJ, HH & C See also Rod End Dimensions, page 111All dimensions are in millimeters unless otherwise stated.Parker Series HMIMetric Hydraulic CylindersPivot MountingsHead depth increased by 5mm to accommodate port on 25mm and 32mm bore cylinders – see page 111*Parker Style SB is also known as Style SBd under Parker’s European model code systemAll dimensions are in millimeters unless otherwise stated.Dimensions – B, BB & SB See also Rod End Dimensions, page 111Parker Series HMIMetric Hydraulic Cylinders25 32 40 50 63 80 100 125 160 200Bore φBAll dimensions are in millimeters unless otherwise stated.1Head depth increased by 5mm to accommodate port on 25mm and 32mm bore cylinders – see page 1112Dimensions to be specified by customerDimensions – D, DB & DD See also Rod End Dimensions, page 111Trunnion MountingsParker Series HMIMetric Hydraulic Cylinders25 32 40 50 63 80 100 125 160 200Bore φBore Rod Add StrokeAdd 2x StrokeφNo.MM φLV PJ SV ZM 25112104538815421832114108568817822240118125731051952281225023612574992073281286324512780932233361368025614493110246345145100270151101107265356156125290175117131289370170160211018813013030239019020021402421601723563110Double Rod CylindersAll dimensions are in millimeters unless otherwise stated.Mounting Styles and CodesDouble rod cylinders are denoted by a ‘K’ in the ISO cylinder model code.DimensionsTo obtain dimensional information for double rod cylinders,first select the desired mounting style by referring to the corresponding single rod model. Dimensions for theappropriate single rod model should be supplemented by those from the table opposite to provide a full set of dimensions.Minimum Stroke Length – Style 9 Rod EndWhere a style 9 (female) piston rod end is required on a double rod cylinder with a stroke of 80mm or less, and a bore of 80mm or above, please consult the factory.CushioningDouble rod cylinders can be supplied with cushions at either or both ends. Cushioning requirements should be specified by inserting a ‘C’ in the ordering code. See cushioning section, Section C of this catalog.Parker Series HMIMetric Hydraulic CylindersDouble Rod CylindersFor double rod cylinders, specify rod number and rod end symbols for both piston rods. A typical model number for a double rod cylinder would be:100KJJ HMI RE14M14M 125M1144BThread Rod Eye Pivot Nominal Weight KK Clevis Bracket Pin Force kNkg M10x1.2514344714480814347780.3M12x1.2514344814480914347812.50.6M14x1.5143449144810143479200.8M16x1.514345014481114348032 2.2M20x1.514345114481214348050 2.7M27x214345214481314348180 5.9M33x21434531448141434821259.4M42x214345414481514348320017.8M48x214345514481614348432026.8M64x314345614481714348550039.0AccessoriesAccessory SelectionAccessories for the rod end of a cylinder are selected by reference to the rod end thread, while the same acces-sories, when used at the cap end, are selected by cylinder bore size. See tables of part numbers below,and on the following pages.The rod clevises, plain rod eyes and spherical bearings fitted as accessories to the rod end have the same pin diameters as those used at the cylinder cap ends of the corresponding mounting styles – B, BB and SB – when fitted with the No.1 rod, or the No. 2 or No. 3 rods with Style 7 rod end.Rod and Cap End AccessoriesAccessories for the HMI ISO cylinder include:Rod End –rod clevis, eye bracket and pivot pin–plain rod eye, clevis bracket and pivot pin –rod eye with spherical bearing Cap End –eye bracket for style BB mounting–clevis bracket for style B mounting–pivot pin for eye bracket and clevis bracketAll dimensions are in millimeters unless otherwise stated.Parker Series HMIMetric Hydraulic CylindersRod Clevis, Eye Bracket and Pivot PinBore Clevis BracketNominal ForceWeight φkN kg 2514364680.43214364712.50.84014364820 1.05014364932 2.56314364950 2.58014365080 5.01001436511259.012514365220020.016014365332031.020014365450041.0Part AW CA CB CD CK EM ERKKLE WeightNo.H9h13kg1434571432189101212M10x1.25130.0814345816362211121617M12x1.25190.15143459183820 12.5142017M14x1.5190.22143460225430 17.5203029M16x1.5320.514346128603020203029M20x1.532 1.114346236754025284034M27x239 1.514346345995035365050M33x254 2.5143464561136550456053M42x257 4.2143465631269056567059M48x26311.81434668516811070708078M64x38317.0AccessoriesPlain Rod Eye, Clevis Bracket and Pivot PinPlain Rod Eye/Knuckle DimensionsClevis Bracket DimensionsClevis Bracket – For Style BPlain Rod Eye/KnucklePivot Pin for Clevis Bracket and PlainRod Eye – DimensionsAll dimensions are in millimeters unless otherwise stated.Parker Series HMIMetric Hydraulic CylindersThread Plain Clevis Nominal WeightKK Rod Eye Bracket Pivot Pin Force kN kg M10x1.2514345714364614347780.5M12x1.2514345814364714347812.5 1.0M14x1.514345914364814347920 1.3M16x1.514346014364914348032 3.2M20x1.514346114364914348050 3.8M27x214346214365014348180 6.9M33x214346314365114348212512.5M42x214346414365214348320026.0M48x214346514365314348432047.0M64x314346614365414348550064.0Part CK CM CW FLMRHB LE RC TBUR UH No.H9A16maxmin143646101262312 5.51318473560143647121682917 6.61924574570143648142010291791930685585143649203015482913.5324510280125143650284020593417.53960135100170143651365025795017.554751671302001436524560308753265790183150230143653567035103593063105242180300143654708040132783382120300200360Part EKEL WeightNo.f8kg14347710290.0214347812370.0514347914450.0814348020660.214348128870.414348236107 1.014348345129 1.814348456149 4.214348570169 6.0BBore Mounting Bracket Nominal ForceWeight φand Pivot Pin kN kg 2514553080.63214553112.5 1.34014553220 2.150******** 3.26314553450 6.5801455358012.010014553612523.012514553720037.016014553832079.0200145539500140.0Cap Mounting Bracket and Pivot PinAccessoriesRod Eye with Spherical Bearing,Mounting Bracket and Pivot PinRod Eye with Spherical Bearing DimensionsRod Eye with Spherical BearingAll spherical bearings should be re-packed with grease when servicing. In unusual or severe working conditions, consult the factory regarding the suitability of the bearing chosen.Parker Series HMIMetric Hydraulic CylindersAll dimensions are in millimeters unless otherwise stated.Thread Rod Eye with Mounting Bracket Nominal Weight KK Spherical Bearing and Pivot Pin Force kN kgM10x1.2514525414553080.2M12x1.2514525514553112.50.3M14x1.5145256145532200.4M16x1.5145257145533320.7M20x1.514525814553450 1.3M27x214525914553580 2.3M33x2145260145536125 4.4M42x21452611455372008.4M48x214526214553832015.6M64x314526314553950028.0Part A max AX min EF CH CNEN EU FU KK LF N max MA max P No.max min Nm 14525440152042 12-0.008 10-.012813M10x1.25161710M6145255451722.548 16-0.008 14-.0121113M12x1.25202110M6145256551927.558 20-0.012 16-.0121317M14x1.5252525M8145257622332.568 25-0.012 20-.0121717M16x1.5303025M814525880294085 30-0.012 22-.0121919M20x1.5353645M10145259903750105 40-0.012 28-.0122323M27x2454545M101452601054662.5130 50-0.012 35-.0123030M33x2585580M121452611345780150 60-0.015 44-.0153838M42x26868160M1614526215664102.5185 80-0.015 55-.0154747M48x29290310M2014526319086120240100-0.02070-.0205757M64x3116110530M24Mounting Bracket and Pivot Pin Dimensions - For Style SBPart CFCGCOCP FMFOGLHB KCLG LJ LO RESR TAUJ UK No.K7/h6+0.1, +0.3N9js11js14js130, +0.30js13max js13145530121010304016469 3.328295655124075601455311614164050186111 4.337387470165595801455322016165055206414 4.3394080852058120901455332520256065227816 5.448499810025701401101455343022257085249718 5.4626312011530901601351455354028368010024123228.472731481354012019017014553650353610012535155308.4909219017050145240215145537604450120150351873911.410811022520060185270260145538805550160190352554511.4140142295240802603203401455391007063200210352854812.4150152335300100300400400Mounting Bracket and Pivot PinModel NumbersHow to Order ISO CylindersData Required On All Cylinder OrdersWhen ordering Series HMI cylinders, be sure to specify each of the following requirements:(NOTE: – Duplicate cylinders can be ordered by giving the SERIAL NUMBER from the nameplate of the original cylinder. Factory records supply a quick, positive identification.)a)Bore Sizeb)Mounting StyleSpecify your choice of mounting style – as shown and dimensioned in this catalog. If double rod is required, specify “with double rod.”c)Series Designation (“HMI”)d)Length of Strokee)Piston Rod DiameterCall out rod diameter or rod code number. In Series HMI cylinders, standard rod diameters (Code No. 1) will be furnished if not otherwise specified, unless length of stroke makes the application questionable.f)Piston Rod End Thread StyleCall out thread style number or specify dimensions.Thread style number 4 will be furnished if not otherwise specified.ADDITIONAL DATA is required on orders for cylinders with special modifications.For further information, consult factory.g)Cushions (if required)Specify “Cushion-head end,” “Cushion-cap end” or “Cushion-both ends” as required. If cylinder is to have a double rod and only one cushion isrequired, be sure to specify clearly which end of the cylinder is to be cushioned.h)PistonParker B style pistons are standard. Fluorocarbon also available.i)PortsBSP (ISO 228) are standard.j)Fluid MediumSeries HMI hydraulic cylinders are equipped with seals for use with hydraulic oil. If other than hydraulic oil will be used, consult factory.Service PolicyOn cylinders returned to the factory for repairs, it is standard policy for the Cylinder Division to make such part replace-ments as will put the cylinder in as good as new condition.Should the condition of the returned cylinder be such that expenses for repair would exceed the costs of a new one,you will be notified.Address all correspondence to Service Department at your nearest regional plant listed in the pages of this catalog.Certified DimensionsParker Cylinder Division guarantees that all cylindersordered from this catalog will be built to dimensions shown.All dimensions are certified to be correct, and thus it is not necessary to request certified drawings.Parker Series HMIMetric Hydraulic CylindersBModel NumbersSeries HMI Model Numbers – How to Develop and “Decode” ThemParker Series HMI cylinders can be completely and accuratelydescribed by a model number consisting of coded symbols. To develop a model number, select only those symbols that represent the cylinder required, and place them in the sequence indicated below.Parker Series HMIMetric Hydraulic Cylinders*Mounting Style SB is also known as Parker Style SBd in Parker’s European model code system. ‡Specify XI dimension.Note: Page numbers with a letter prefix, ie: C77, are located in section C of this catalog.。
派克换向阀的工作原理以及优点换向阀工作原理在有些派克PARKER液压系统中,有时需要流量不大的高压油,这时可考虑用增压回路得到高压,而不用单设高压泵。
液压执行元件在工作循环中,某段时间不需要供油,而又不便停泵的情况下,需考虑选择卸荷回路。
在系统的某个局部,派克PARKER液压工作压力需低于主油源压力时,要考虑接受减压回路来获得所需的工作压力。
1.派克PARKER液压泵订立次序动作过程主机各执行机构的次序动作,派克PARKER液压依据设备类型不同,有的按固定程序运行,有的则是随机的或人为的。
工程机械的操纵机构多为手动,一般用手动的多路换向阀掌控。
加工机械的各执行机构的次序动作多接受行程掌控,当工作部件移动到确定位置时,通过电气行程开关发出电信号给电磁铁推动电磁阀或直接压下行程阀来掌控接续的动作。
行程开关安装比较便利,而用派克PARKER液压行程阀需连接相应的油路,因此只适用于管路联接比较便利的场合。
另外还有时间掌控、压力掌控等。
例如派克PARKER液压液压泵无载启动,经过一段时间,当泵正常运转后,延时继电器发出电信号使卸荷阀关闭,建立起正常的工作压力。
压力掌控多用在带有液压夹具的机床、挤压机压力机等场合。
当某一执行元件完成预定动作时,回路中的压力达到确定的数值,通过压力继电器发出电信号或打开次序阀使压力油通过,来启动下一个动作。
2.派克PARKER液压泵选择液压动力源液压系统的工作介质完全由液压源来供应,派克PARKER液压源的核心是液压泵。
节流调速系统一般用定量泵供油,在无其他辅佑襄助油源的情况下,液压泵的供油量要大于系统的需油量,多余的油经溢流阀流回油箱,溢流阀同时起到掌控并稳定油源压力的作用。
容积调速系统多数是用变量泵供油,用安全阀限定系统的高压力。
为节省能源提率,派克PARKER液压泵的供油量要尽量与系统所需流量相匹配。
对在工作循环各阶段中系统所需油量相差较大的情况,一般接受多泵供油或变量泵供油。