This .pdf document is bookmarkedOperating Instructions and Parts ManualAir Filtration SystemModel PM1200427 New Sanford RoadLaVergne, Tennessee 37086 Part No. M-1791330Ph.: 800-274-6848 Revision B209/2018 Copyright © 2017 PowermaticWarranty and ServicePowermatic® warrants every product it sells against manufacturers’ defects. If one of our tools needs service or repair, please contact Technical Service by calling 1-800-274-6846, 8AM to 5PM CST, Monday through Friday. Warranty PeriodThe general warranty lasts for the time period specified in the literature included with your product or on the official Powermatic branded website.•Powermatic products carry a limited warranty which varies in duration based upon the product. (See chart below)•Accessories carry a limited warranty of one year from the date of receipt.•Consumable items are defined as expendable parts or accessories expected to become inoperable within a reasonable amount of use and are covered by a 90 day limited warranty against manufacturer’s defects. Who is CoveredThis warranty covers only the initial purchaser of the product from the date of delivery.What is CoveredThis warranty covers any defects in workmanship or materials subject to the limitations stated below. This warranty does not cover failures due directly or indirectly to misuse, abuse, negligence or accidents, normal wear-and-tear, improper repair, alterations or lack of maintenance. Powermatic woodworking machinery is designed to be used with Wood. Use of these machines in the processing of metal, plastics, or other materials may void the warranty. The exceptions are acrylics and other natural items that are made specifically for wood turning.Warranty LimitationsWoodworking products with a Five Year Warranty that are used for commercial or industrial purposes default to a Two Year Warranty. Please contact Technical Service at 1-800-274-6846 for further clarification.How to Get Technical SupportPlease contact Technical Service by calling 1-800-274-6846. Please note that you will be asked to provide proof of initial purchase when calling. If a product requires further inspection, the Technical Service representative will explain and assist with any additional action needed.Powermatic has Authorized Service Centers located throughout the United States. For the name of an Authorized Service Center in your area call 1-800-274-6846 or use the Service Center Locator on the Powermatic website.More InformationPowermatic is constantly adding new products. For complete, up-to-date product information, check with your local distributor or visit the Powermatic website.How State Law AppliesThis warranty gives you specific legal rights, subject to applicable state law.Limitations on This WarrantyPOWERMATIC LIMITS ALL IMPLIED WARRANTIES TO THE PERIOD OF THE LIMITED WARRANTY FOR EACH PRODUCT. EXCEPT AS STATED HEREIN, ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE EXCLUDED. SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU. POWERMATIC SHALL IN NO EVENT BE LIABLE FOR DEATH, INJURIES TO PERSONS OR PROPERTY, OR FOR INCIDENTAL, CONTINGENT, SPECIAL, OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OF OUR PRODUCTS. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU.Powermatic sells through distributors only. The specifications listed in Powermatic printed materials and on the official Powermatic website are given as general information and are not binding. Powermatic reserves the right to effect at any time, without prior notice, those alterations to parts, fittings, and accessory equipment which they may deem necessary for any reason whatsoever.Product Listing with Warranty Period90 Days – Parts; Consumable items1 Year – Motors, Machine Accessories2 Year – Woodworking Machinery used for industrial or commercial purposes5 Year – Woodworking MachineryNOTE: Powermatic is a division of JPW Industries, Inc. References in this document to Powermatic also apply to JPW Industries, Inc., or any of its successors in interest to the Powermatic brand.Table of ContentsWarranty and Service (2)Table of Contents (3)Warning (4)Introduction (5)Specifications (5)Grounding Instructions (6)Unpacking (7)Contents of the Shipping Container (7)Assembly (7)Installation (7)Controls and Features (7)Operation (8)Changing Filters (8)Transmitter Replacement (9)Hole Dimensions (9)Replacement Parts (10)Parts Breakdown for PM1200 Air Filtration System (11)Parts List for PM1200 Air Filtration System (12)Electrical Connections (13)1. Read and understand the entire owner’s manual before attempting assembly or operation.2. Read and understand the warnings posted on the machine and in this manual. Failure to comply withall of these warnings may cause serious injury.3. Replace warning labels if they become obscured or removed.4. Always wear approved safety glasses/face shields while using woodworking equipment. Everydayeyeglasses only have impact resistant lenses; they are not safety glasses.5. When using woodworking equipment, remove tie, rings, watches and other jewelry, and roll sleevesup past the elbows. Remove all loose clothing and confine long hair. Non-slip footwear or anti-skid floor strips are recommended.6. Wear ear protectors (plugs or muffs) during extended periods of operation.7. Do not operate equipment while tired or under the influence of drugs, alcohol or any medication.8. Make certain the machine is properly grounded.9. Disconnect the filtration unit from the power source (unplug) before servicing or changing filters.10. Form a habit of checking to see that adjusting wrenches, rags, etc. are removed from the machinebefore turning it on.11. If ceiling mounted, bottom of filtration unit must be at least 7 feet from the floor.12. If ceiling mounted, mounts must be anchored to building structure which will support a minimum of atleast 100 pounds. Never mount to surfaces such as dry wall, false ceiling grids, etc.13. Do not expose filtration unit to water or rain.14. Never duct a machine directly into the air filtration unit.15. Do not use this equipment to filter flammable vapors. This air filtration unit is designed and intendedfor the filtration of air borne wood dust only. It is neither designed nor intended for any other purpose whatsoever. If used for other purposes, Powermatic disclaims any real or implied warranty and holds itself harmless from any injury that may result from that use.16. Keep safety guards in place at all times when the machine is in use. If removed for maintenancepurposes, use extreme caution and replace the guards immediately after maintenance is complete. 17. Check damaged parts. Before further use of the machine, a guard or other part that is damagedshould be carefully checked to determine that it will operate properly and perform its intended function. A guard or other part that is damaged should be properly repaired or replaced.18. Keep the floor around the machine clean and free of scrap material, oil and grease.19. Keep visitors a safe distance from the work area. Keep children away.20. Make your workshop child proof with padlocks, master switches or by removing starter keys.21. Give your work undivided attention. Looking around, carrying on a conversation and “horse-play” arecareless acts that can result in serious injury.22. Use recommended accessories; improper accessories may be hazardous.23. Do not stand on the filtration unit. Serious injury could occur if the unit tips over.WARNING:of California to cause cancer and birth defects or other reproductive harm. For more information go toWARNING:substances known to the State of California to cause cancer. Avoid inhaling dust generated fromFamiliarize yourself with the following safety notices used in this manual:This means that if precautions are not heeded, it may result in minor injury and/or possible machine damage.This means that if precautions are not heeded, it may result in serious injury or possibly even death.IntroductionThis manual is provided by Powermatic covering the safe operation and maintenance procedures for a Powermatic Model PM1200 Air Filtration System. This manual contains instructions on installation, safety precautions, general operating procedures, maintenance instructions and parts breakdown. This machine has been designed and constructed to provide consistent, long-term operation if used in accordance with instructions set forth in this manual. If there are any questions or comments, please contact either your local supplier or Powermatic. Powermatic can also be reached at our web site: . Register your product using the mail-in card provided, or register online:/us/en/service-and-support/product-registration/SpecificationsModel Number .................................................................................................................................... P M1200 Stock Number .. (1791330)Efficiency of Outer Filter ........................................................................................ 99 % of 5 micron particles Efficiency of Inner Filter ......................................................................................... 85 % of 1 micron particles Remote Transmitter ............................................................................................................... radio frequency Blower Speeds . (3)Timer Settings (hours) ............................................................................................................................ 1 to 9 Cabinet Material ...................................................................................................................... 20 gauge steel Overall Dimensions (L x W x H)(in.) ............................................................................................ 33 x 25 x 13 ********************:High Speed ................................................................................................................................... 65 dB Medium Speed ............................................................................................................................... 58 dB Low Speed ..................................................................................................................................... 52 dB Air Flow, filtered:High Speed ............................................................................................................................ 1196 CFM Medium Speed ......................................................................................................................... 706 CFM Low Speed ............................................................................................................................... 547 CFM Motor ......................................................................................................................... 1/4HP, 1 PH, 115V only Amps .......................................................................................................................................... 3.5 / 2.8 / 2.3 Net Weight, approximate (lbs.) . (67)Shipping Weight, approximate (lbs.) (74)The above specifications were current at the time this manual was published, but because of our policy of continuous improvement, Powermatic reserves the right to change specifications at any time and without prior notice, without incurring obligations.Grounding InstructionsElectrical connections must be made by a qualified electrician in compliance with all relevant codes. This machine must be properly grounded to help prevent electrical shock and possible fatal injury.In the event of a malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This tool is equipped with an electric cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into a matching outlet that is properly installed and grounded in accordance with all local codes and ordinances.Do not modify the plug provided. If it will not fit the outlet, have the proper outlet installed by a qualified electrician.Improper connection of the equipment-grounding conductor can result in a risk of electric shock. The conductor, with insulation having an outer surface that is green with or without yellow stripes, is the equipment-grounding conductor. If repair or replacement of the electric cord or plug is necessary, do not connect the equipment-grounding conductor to a live terminal.Check with a qualified electrician or service personnel if the grounding instructions are not completely understood, or if in doubt as to whether the tool is properly grounded. Use only three wire extension cords that have three-prong grounding plugs and three-pole receptacles that accept the tool’s plug.Repair or replace a damaged or worn cord immediately.115 Volt OperationThe Air Filtration Unit is ready to run at 115 volt operation. It is intended for use on a circuit that has an outlet and a plug similar to the one illustrated in Figure A. A temporary adapter, which looks like the adapter as illustrated in Figure B, may be used to connect this plug to a two-pole receptacle, as shown in Figure B if a properly grounded outlet is not available. The temporary adapter should only be used until a properly grounded outlet can be installed by a qualified electrician. This adapter is not applicable in Canada. The green colored rigid ear, lug, or tab, extending from the adapter, must be connected to a permanent ground such as a properly grounded outlet box, as shown in Figure B.BFigureA FigureIf an extension cord is necessary, make sure the cord rating is suitable for the Air Filtration Unit’s listed amperage. An undersize cord will cause a drop in line voltage resulting in loss of power and overheating. Use the chart in Figure C as a general guide in choosing the correct size cord. If in doubt, use the next heavier gauge. The smaller the gauge number, the heavier the cord.Cord Length(115V operation)Cord Gauge25 16AWGAWG50 16100 14AWGAWG150 12Figure CUnpackingInspect the Air Filtration Unit and check for shipping damage. Report any damage immediately to your distributor and shipping agent. Do not discard any shipping material until the Air Filtration Unit is installed and running properly.Compare the contents of your container with the following parts list to make sure all parts are intact. Missing parts, if any, should be reported to your distributor.Contents of the Shipping Container1 Air Filtration Unit1 Remote Control with Mounting Bracket1 9 Volt Battery4 Eye Bolts4 Hex Nuts4 Flat Washers1 Instruction and Parts Manual1 Warranty CardAssemblyRefer to Figure 1.Tools required: 10mm wrench and cross-point screwdriver1. Remove both filter guards by pulling out onthe tabs so that they clear the slots in thesides of the cabinet.2. Remove the outer filter and inner filter(intake side) and the diffusion filter (exhaustside). Remove any protective plastic fromthese items.3. Remove all styrofoam packing from insidethe cabinet.4. Re-install the filters and filter guards inproper order. The filters at the intake sideshould be placed inside the retaining plateon the cabinet.(The outer filter has an arrow printed on it toshow direction of air flow; make sure it isfacing the proper direction when installed.)5. If you will be suspending the unit from anoverhead structure, remove the four screwson top of the cabinet. Install the four eyebolts with hex nuts and washers into thethreaded holes. Screw each eye bolt into thecabinet; turn it to desired position thentighten the hex nut against the cabinet with a10mm wrench.InstallationThe unit must be anchored to a building structure which will support a minimum of 100 pounds. Never mount to surfaces such as dry wall, false ceiling grids, etc.If mounting to ceiling, make sure chain and ceiling hooks are properly rated for hanging this unit. Clearance should be at least 7 feet from bottom of unit to the floor.This unit will work best if located away from corners and heating/cooling vents. Controls and FeaturesRefer to Figure 2.The Air Filtration Unit can be operated by either the remote transmitter or the control panel on the cabinet. The remote transmitter uses radio frequency, and thus is not limited by line-of-sight operation.FuseThe fuse switch will pop out in case of overload. Wait 3 to 5 minutes and push the fuse switch back in.SpeedThe unit will always start on low speed. On the remote, press the up or down button to change speed. Or, on the control panel, press and release the Speed button.TimerPress the timer button on the remote (the timer indicator will start flashing). Then press the up or down button to scroll to the desired time (from 1 to 9 hours). Press the timer button again – the indicator will stop flashing. The unit will operate for the programmed time, at the end of which it will automatically shut off.Note: If the timer function is not used, the filtration unit will continue to operate until the off button is pressed.Change FilterThe “Change Filter” indicator will light up after 200 hours of operation to remind the operator to inspect and to clean/replace filters if needed.To turn off the indicator light, press the Reset switch using a thin object, such as a ball point pen or paper clip.Figure 1Figure 2OperationNOTE: The Air Filtration Unit is designed to remove airborne non-metallic dust particles; it is not designed to take the place of a dust collection system.Larger particles are trapped by the outer filter. Smaller particles are stopped by the fine mesh pockets of the inner filter. The air is then exhausted through the diffusion filter, which has a fibrous composition to help diffuse the air.Changing FiltersRefer to Figure 1.Turn off, disconnect (unplug)the Air Filtration Unit from the power source before servicing or changing filters.There are two filters that need to be cleaned and/or replaced periodically, depending upon the amount of use and the environment of your shop. Using clogged filters will diminish the overall efficiency of the unit.The outer filter is disposable, but its life can be extended by occasional use of a shop vac or compressed air to clean off the dust. For maximum efficiency, however, a dirty outer filter should be discarded and replaced with a new one. (An optional, washable outer filter is available – stock no. 1791085.)The inner filter can be blown out with compressed air.The diffusion filter will not need replacing. It should be inspected occasionally, and if needed, cleaned by light vacuuming or compressed air. (An optional charcoal diffusion filter – stock no. 1791084 – may be purchased, and is used to reduce odors and non-flammable vapors.) Transmitter ReplacementThe remote transmitter provided with your Air Filtration Unit is pre-programmed and ready to operate once the battery is installed. However, should you ever need to replace the remote transmitter, the new transmitter will need to be programmed for your Air Filtration Unit. This is easily done, as follows (Figures 4 and 5):1. Start the Air Filtration Unit.2. On the Air Filtration Unit’s control panel,press and hold the Speed and Timer buttons simultaneously for 4 seconds, until you heara “beep”.3. Turn on the remote transmitter.4. You should now be able to operate themachine using the remote transmitter.Figure 3 Figure 4Hole DimensionsFigure 5Replacement PartsReplacement parts are listed on the following pages. To order parts or reach our service department, call 1-800-274-6848 Monday through Friday, 8:00 a.m. to 5:00 p.m. CST. Having the Model Number and Serial Number of your machine available when you call will allow us to serve you quickly and accurately. Non-proprietary parts, such as fasteners, can be found at local hardware stores, or may be ordered from Powermatic.Some parts are shown for reference only, and may not be available individually.Parts Breakdown for PM1200 Air Filtration SystemParts List for PM1200 Air Filtration SystemIndex No. Part No. Description Size Qty1 ............... 1791083 ................... O uter Filter for PM1200 ....................................... 12”x24”x1” . (1)2 ............... 1791082 ................... I nner Filter for PM1200 ........................................ 12”x24”x1” . (1)3 ............... P M1200-03 .............. R etaining Plate ..................................................... (1)4 ............... P M1200-04 .............. R ivet ..................................................................... NSS 4-4 . (2)5 ............... P M1200-05 .............. E ye Bolt * ............................................................. M6 . (4)6 ............... T S-1540041 ............. H ex Nut * .............................................................. M6 . (4)7 ............... T S-1550041 ............. F lat Washer * ....................................................... M6 . (4)8 ............... T S-1534032 ............. P hillips Pan Head Machine Screw ....................... M6x8 (4)9 ............... P M1200-09 .............. S pecial Nut ........................................................... M6 . (4)10 ............. T S-1550041 ............. F lat Washer .......................................................... M6 . (6)11 ............. T S-1551041 ............. L ock Washer ........................................................ M6 . (6)12 ............. T S-1503031 ............. S ocket Head Cap Screw ...................................... M6x12 . (6)13 ............. P M1200-13 .............. D iffusion Filter ...................................................... (1)14 ............. P M1200-14 .............. F ilter Guard (re: PM1200-14A).............................. (2)15 ............. P M1200-15 .............. S hort Chrome Strip (re: PM1200-14A).................. (4)................. P M1200-14A ............ F ilter Guard Assembly (includes #14 and 15) ...... (1)16 ............. P M1200-16 .............. C abinet ................................................................. (1)................. P M1200-16A ............ C abinet Assembly (includes #3, 4, 9 and 16) ...... (1)17 ............. P M1200-17 .............. C ontrol Switch Assembly ..................................... (1)17-1 .......... P M1200-1701 .......... C ircuit Board Assembly ........................................ (1)17-2 .......... T S-1540031 ............. H ex Nut ................................................................ M5 . (2)17-3 .......... P M1200-1703 .......... T oothed Washer .................................................. M5 . (2)17-4 .......... P M1200-1704 .......... S witch Plate ......................................................... (1)17-5 .......... T S-1531012 ............. C ounter Sunk Screw ............................................ M3x6 (4)17-6 .......... P M1200-1706 .......... C ontrol Switch Label ............................................ (1)17-7 .......... P M1200-1707 .......... T hermos Switch ................................................... 5A .. (1)17-8 .......... T S-1533042 ............. P hillips Pan Head Machine Screw ....................... M5x12 . (1)17-9 .......... P M1200-1709 .......... W iring Nut ............................................................ P2 .. (1)17-10 ........ P M1200-1710 .......... S train Relief.......................................................... (1)17-11 ........ P M1200-1711 .......... P ower Cord .......................................................... 18AWGx3C .. (1)18 ............. P M1200-18 .............. T apping Screw ..................................................... M4x6 (4)19 ............. P M1200-19 .............. C oncave Handle .................................................. (2)20 ............. P M1200-20 .............. R F Transmitter Assembly .................................... (1)20-1 .......... P M1200-2001 .......... R F Transmitter ..................................................... (1)20-2 .......... P M1200-2002 .......... H older ................................................................... (1)20-3 .......... P M1200-2003 .......... W ood Screw ......................................................... M3x12 . (2)21 ............. ................................. B attery (local purchase) ....................................... 9 Volt (1)22 ............. 6823013 ................... B lack Stripe .......................................................... (2)23 ............. P M1200-23 .............. L ong Chrome Strip ............................................... (2)24 ............. P M1200-24 .............. B lower Assembly ................................................. (1)24-1 .......... T S-1503071 ............. S ocket Head Cap Screw ...................................... M6x30 . (4)24-2 .......... T S-1550041 ............. F lat Washer .......................................................... M6 . (4)24-3 .......... P M1200-2403 .......... S leeve .................................................................. (4)24-4 .......... P M1200-2404 .......... R ubber Pad .......................................................... (4)24-5 .......... T S-1540031 ............. H ex Nut ................................................................ M5 . (4)24-6 .......... P M1200-2406 .......... M otor Bracket ....................................................... (1)24-7 .......... P M1200-2407 .......... M otor .................................................................... 1/4HP, 115V (1)24-8 .......... T S-1534032 ............. P hillips Pan Head Machine Screw ....................... M6x8 . (12)24-9 .......... P M1200-2409 .......... A ir Guide Plate ..................................................... (2)24-10 ........ P M1200-2410 .......... F an Blade ............................................................. (1)24-11 ........ T S-1504021 ............. S ocket Head Cap Screw ...................................... M8x12 . (1)24-12 ........ P M1200-2412 .......... F an Housing ......................................................... (1)................. P M1200-HD ............. H ardware Kit (includes index # 5, 6 and 7) .......... (1)................. P M1200-ID ............... I.D. Label (not shown) .......................................... (1)................. L M000334 ................ W arning Label (not shown) .................................. (1)Replacement Filters:Stock No. Description1791082 ........................... Inner Filter, PM1200, 12”x24”x1”1791083 ........................... Disposable Outer Filter, PM1200, 12”x24”x1”1791084 ........................... Charcoal Diffusion Filter, PM1200 (optional)1791085 ........................... Washable Electrostatic Filter, PM1200, 12”x24”x1” (optional) Electrical Connections。
PL1200混凝土配料机使用说明书目录1、产品用途及特点 (1)2、主要技术参数 (1)3、结构组成与工作原理 (1)4、安装与调试 (2)5、配料系统设置 (3)6、操作维护规程及注意事项 (3)7、常见故障及排除方法 (4)1.产品用途及特点PL1200混凝土配料机是一种与搅拌机配套使用的前台自动配料设备。
它可根据用户设定的混凝土配比自动完成砂、石、水泥等三种以上物料的配料程序。
该产品依照GB10172《混凝土搅拌站技术条件》中配料系统的技术标准设计。
整机具有称量准确,配料精度高,速度快,控制功能强等特。
该产品采用电子称量,能自动进行动态零位跟踪及过冲量的自动测定和修正;数字显示,有主辅两个LED 数码显示窗,实时显示每种配料的重量和配料的累计重量;能方便的进行10种配方的保存和提取以及自动保存当前使用配方;具有完善的保护和故障诊断功能,有线遥控操作。
并且采用了分布式计算机控制,可以构成更大的控制系统。
PL1200混凝土配料机与相应的混凝土搅拌机组合,可组成各种不同形式、不同规格的组合式搅拌站,而造价仅为同规格搅拌站的1/2-1/3,且移动、安装十分方便,是生产高质量混凝土的理想设备。
PL1200混凝土配料机与双向输送皮带机配套,可供两台搅拌机配料,达到极佳的经济效果。
2.主要技术参数称量斗公称容积: 1.5m3储料斗容积:2×2.5m3生产率:60m3/h配料精度:±2%检定分度值: 2.0kg准确度等级:IIII最大称量值:2000kg可配骨料种数:3种上料高度:2300mm皮带机带速: 1.25m/s总功率:16(4×4)kw整机质量:4200kg外形尺寸:(长×宽×高)9200×2200×3000mm3.结构组成与工作原理3.1结构组成PL1200混凝土配料机由给料系统、称量系统、和微机控制系统三大部分组成。
整体结构见整机示意图。
1. Do not install this equipment in a confined or building-in space such as a book case or similar unit, and remain a well ventilation conditions at open site. The ventilation should not be impeded by covering the ventilation openings with items such as newspaper, table-cloths, curtains etc.2. No naked flame sources, such as lighted candles, should be placed on the apparatus.3. The product is designed to use in moderate climates4. Voltage selector: Used to adjust the input rating (110-120 Vac/60 Hz and 220-240 Vac/50 Hz), please just insert the mains power plug into the socket-outlet with voltage within the setting of the selector. The current ratings of mains fuse links are different for different input rating (see marking for details), and the fitted mains fuse link was just related to the input rating as setting of the selector during factory assembly line work, please ask a qualified personnel to help you replace the mains fuse link before you adjust the voltage selector.5. Protective earthing terminal. The apparatus should be connected to a mains socket outlet with a protective earthing connection. In Denmark: “Apparatets stikprop skal tilsluttes en stikkontakt med jord, som giver forbindelse til stikproppens jord.” In Finland: "Laite on liitettävä suojakoskettimilla varustettuun pistorasiaan" In Norway: “Apparatet må tilkoples jordet stikkontakt” In Sweden: “Apparaten skall anslutas till jordat uttag”IMPORTANT SAFETY INSTRUCTIONSWARNING1. Only use attachments/accessories specified or provided by the manufacturer.2. To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.The apparatus shall not be exposed to dripping or splashing and that objects filled with liquids, such as vases, shall not be placed on apparatus.3. The mains plug is used as disconnect device, the disconnect device shall remain readily operable.TABLE OF CONTENTS....................................................................................................................................................................................1 ................................................................................................................2 3 4 ............................................................................5 ...................................................................................5 6 ..................................................................................................................................................................7 ..................................................................................................................................................7 ...........................................................................................7 ......................................................................................................7 ..................................................................................7 .....................................................................................................7 ...........................................................................................7 ..................................................................................................................7INCLUDED ITEMS ATTACHING THE GRILLE SUBWOOFER REAR-PANEL CONTROLS AND CONNECTION ...........................................PLACING THE SUBWOOFER MAKING CONNECTIONS CONNECTING TO A STEREO RECEIVER, AMPLIFIER OR PREAMPLIFIER ...................SPECIFICATIONS OPERATING THE SUBWOOFER TURNING THE SUBWOOFER ON AND OFFSUBWOOFER ADJUSTMENTS: CROSSOVER SUBWOOFER ADJUSTMENTS: VOLUMESUBWOOFER ADJUSTMENTS: PHASEABNORMAL CONDITION :LED flashing USING THE SUPPLIED CARPET SPIKESCONNECTING THE SUBWOOFER TO A TRIGGER VOLTAGE SOURCE ...................................INCLUDED ITEMSYour new JBL ® powered subwoofer incorporates a high-performance transducer and built-in amplifier that delivers the powerful, dynamic and accurate low-frequency performance that makes your filmsoundtracks and music come alive. And with adjustable crossover, phase controls and automatic turn on/off, it is also simple to connect and set up.We’re confident that this JBL subwoofer will provide every note of enjoyment that you expect – and that when you think about purchasing additional audio equipment for your home, car or office, you will once again choose JBL products.This quick-start guide contains all the information you need to set up, connect and adjust your new subwoofer. For morein-depth information, go to our web site:.Powered SubwooferTHANK YOU FOR CHOOSING THIS JBL ® PRODUCTHDI-1200P4X Note: Type of power plug varies by regions.1X1X1One combination LFE and trigger cableE n g l i s hSUBWOOFER REAR-PANEL CONTROLS AND CONNECTION1)Power Mode :When switched to 'Auto' position, the subwoofer will then be in Standby mode. It will automatically turn on when an audio signal is detected and will return to the Standby mode when no audio signal is detected after approximately 10 minutes. Setting this switch to ‘On’ keeps the subwoofer powered until Power Switch is turned 'Off.'2)On/Standby LED:When the Power Switch is in the ‘On’ position, this LED indicates whether the subwoofer is in the On or Standby state.••When the LED glows red, the subwoofer is in the Standby mode.4)Low Pass Crossover:This control determines the highest frequency at which the subwoofer reproduces sounds. The higher you set the Crossover control, the higher in frequency the subwoofer will operate and the more its bass will“overlap” that of the speakers. This adjustment helps achieve a smooth transition of bass frequencies between the subwoofer and the speakers for a variety of different rooms and subwoofer locations.5) Subwoofer Gain:Use this control to adjust the subwoofer’s volume. Turn the knobclockwise to increase the volume; turn the knob counterclock-wise to decrease the volume.6)Input Connectors:Connect these to the outputs of a stereo preamp or connect a surround processor's subwoofer output to either the left or right input. Balanced (XLR) and unbalanced (RCA) connectors are available. The inputs are 0dBV nominal to +12dBV max unbal/+18dBV max bal. The XLR input is pin 2 hot.7)Power Switch:Set this switch in the ‘On’ position to turn the subwoofer on. If you willbe away from home, or will not be using the subwoofer for an extended period, set this switch in the ‘Off’ position to conserve energy.8)Power Cord Connector:After you have made and verified the subwoofer’s input connection,plug the power cord into an active, unswitched electrical outlet for proper operation of the subwoofer.DO NOT plug the power cord into the accessory outlets found on someaudio components.3)Phase Switch:This switch determines whether the subwoofer transducer’s piston-like action moves in and out in phase with the main speakers. If thesubwoofer were to play out of phase with the main speakers, the sound waves from the main speakers could partially cancel out the sound waves from the subwoofer, reducing bass performance and sonic impact. This phenomenon depends in part on the placement of all the speakers relative to the listening position and to each other in the room.9) 12V Trigger In/Out connectors:When the subwoofer’s Power Mode Switch is set to “Trigger”, the subwoofer will automatically turn on when 5V-12V is present at the 12V Trigger “in-connection”, and will turn off when the voltage at this connection is removed. Whenever the subwoofer in on, a 12V trigger signal is available at it’s 12V Trigger Out connector. It is for use with additional HDI-1200P subwoofers, or another triggerable device.11) EQ Frequency control:Selects the center frequency of the particular problem area. The range is from 32HZ to100Hz.12) EQ Bandwidth control:Sets the range of frequencies over which the equalizer will have an effect. The range is from 0.1 octaves to 0.6 octaves; the higher the number the broader the range of frequencies that will be affected.13) EQ Level control:Allows you to adjust how much boost or cut is applied to the selected frequency by the EQ Frequency Control. This control adjusts from-12dB to a maximum of +3dB.14) EQ On/Off switch:Enables/Disables the parmetric EQ controls (Frequency, Bandwidth, and EQ Level, but not Phase)81,3412111056910) Parametric Equalization (PEQ) controls:This set of equalization controls adjust for the dominant room mode at yourlistening position in your specific listening room. The parametric equalizer includes variable controls to adjust Frequency, Bandwidth, and EQ Level of one band of frequencies. To use these controls, you must first set the EQ switch to “ON”. NOTE: Specific measurement equipment is required to properly adjust the Equalization controls. Your authorized JBL dealer can make the appropriate measurements, using suitable equipment to ensure optimal results.3When the LED glows green , the subwoofer is turned On.CONNECTING THE SUBWOOFER TO A TRIGGER VOLTAGE SOURCE12VTRIGGEROUTPUTThe subwoofer will automatically turn on if it receives a trigger voltage at its External Trigger Input connector and will enter the Standby mode when the voltage ceases.If your preamp/processor or another audio/video component has a trigger-voltage connection that supplies between 3V and 30V (AC or DC), connect it to subwoofer’s Exteranl Trigger Input connector. If the component’s trigger-voltage connection has a 3.5mm mini jack, you can use the supplied combination LFE/trigger cable to make the connection.NOTE: Do not connect the subwoofer’s External Trigger input connector to a remote control output (IR Out) of your home cinema system or surround receiver. Doing so could lead to malfunction.4PLACING THE SUBWOOFERThe performance of a subwoofer is directly related to its placement in the listening room and its physical position relative to the other speakers in the system.While it is true that in general our ears do not hear directional sounds at the lowfrequencies where subwoofers operate, when installing a subwoofer within the limited confines of a room, the reflections, standing waves and absorptions generated within the room will strongly influence the performance of any subwoofer system. As a result, the specific location of the subwoofer in the room does become important to the amount and quality of bass that is produced.For example, placing the subwoofer next to a wall generally will increase the amount of bass in the room; placing it in a corner (1) generally will maximize amount of bass in the room. However, corner placement can also increase the destructive effect of standing waves on bass performance. This effect can vary depending on the listening position – some listening positions may yield very good results while others may have far too much (or too little) bass at certain frequencies.In many rooms, placing the subwoofer along the same plane as the left and rightspeakers (2) can produce the best integration between the sound of the subwoofer and that of the left and right speakers. In some rooms, the best performance could even result from placing the subwoofer behind the listening position (3).We strongly recommend that you experiment with placement before choosing a final location for your subwoofer. One way you can determine the best location for the subwoofer is by temporarily placing it in the listening position and playing music with strong bass content. Move around to various locations in the room while the system is playing (putting your ears where the subwoofer would be placed), and listen until you find the location where the bass performance is best. Place the subwoofer in that location.MAKING CONNECTIONSCAUTION: Never make or break connections unless all system components are powered off.5CONNECTING TO A STEREO RECEIVER,AMPLIFIER OR PREAMPLIFIERIf you are connecting to a stereo device, connect the subwoofer asshown below. Stereo components rarely have subwoofer outputs. Usethem if they are available; otherwise, be sure to use a Y-connector for theleft output and one for the right output, connecting the subwoofer input toone side of each Y and the input for the left or right or right main speaker amplifierto the other side of the Y for proper main speaker operation. You can make either balanced (XLR) or unbalanced (RCA) connections between the device and the subwoofer.Using this connection method, you must set the Low Pass Crossoverknob to some frequency between 50-150Hz, NOT on the “LFE”setting.6TURNING THE SUBWOOFER ON AND OFFSet the subwoofer’s Power Switch to the ‘On’ position. Now set the subwoofer’s Power Mode to the ‘Auto’ position. The subwoofer willautomatically turn itself on when it receives an audio signal, and it will go into Standby mode after it has received no audio signal for approximately If you will not be using the subwoofer for an extended period – forinstance, if you’re going on vacation – set the Power Switch to the ‘Off’ position.SUBWOOFER ADJUSTMENTS: CROSSOVERThe Crossover control adjusts the subwoofer’s built-in low-pass filter crossover between 50Hz and 150Hz. The higher you set the Crossover control, the higher in frequency the subwoofer will operate and the more its bass will ‘overlap’ that of the speakers. This adjustment helps achieve a smooth transition of bass frequencies between the subwoofer and the speakers for a variety of different rooms and subwoofer locations.To set the Crossover control, listen for the smoothness of the bass. If the bass seems too strong at certain frequencies, try a lower Crossover control setting. If the bass seems too weak at certain frequencies, try a higher Crossover control setting.SUBWOOFER ADJUSTMENTS: VOLUMEUse the volume control to set the subwoofer’s volume. Turn the knob clockwise to increase the subwoofer’s volume; turn the knobcounterclock-wise to decrease the volume. Once you have balanced the subwoofer’s volume with that of the other speakers in your system, you shouldn’t have to change the volume control setting.Notes on Setting Subwoofer Volume:•Sometimes the ideal subwoofer volume setting for music is too loud for films, while the ideal setting for films is too quiet for music. When setting the subwoofer volume, listen to both music and films with strong bass content and find a ‘middle ground’ volume level that works for both.•If your subwoofer always seems too loud or too quiet, you may want to place it in a different location. Placing the subwoofer in a corner will tend to increase its bass output, while placing it away from any walls or corners will tend to lessen its bass output.SUBWOOFER ADJUSTMENTS: PHASEThe Phase switch determines whether the subwoofer driver’s piston-like action moves in and out in phase with the speakers. If the subwoofer were to play out of phase with the speakers, the sound waves from the speakers could partially cancel out the waves from the subwoofer, reducing bass performance and sonic impact. This phenomenon depends in part on the placement of all the speakers relative to each other and the listener(s) in the room.Although in most cases you should leave the Phase switch in the ‘Normal’ position, there is no absolutely correct setting for the Phase switch. When the subwoofer is properly in phase with the speakers, the sound will be clearer and have maximum impact, and percussive sounds like drums, piano and plucked strings will sound more life-like. The best way to set the Phase switch is to listen to music that you know well and to set the switch in the position that gives drums and other percussive sounds maximum impact.USING THE SUPPLIED CARPET SPIKESFour metal spikes are supplied for use when you place the subwoofer on a carpeted surface. Do not use these spikes when placing subwoofer on non-carpeted surfaces.To insert the spikes:1.Gently lay the subwoofer on its side (not its front or back) on a soft,nonabrasive surface.2.Screw each spike into the threaded insert in each foot. Make sure all four spikes are screwed in completely for stability.Note : NEVER drag the subwoofer to move it. Always carefully lift the subwoofer and carry it to its new location.OPERATING THE SUBWOOFERHDI-1200PMODEL DESCRIPTION ENCLOSURETYPE SPECIFICATIONS1000W RMS Powered Subwoofer CROSSOVER FREQUENCY12-inch / 300mm black paper cone, cast-frame woofers70.08lb (31.79kg)Bass-reflex design with down-firing ports COMPONENTS LF DRIVER50Hz – 150Hz (variable) 24dB/octave FREQUENCY RESPONSE28Hz - 150Hz(-6dB)POWER REQUIREMENT 100V - 240V 50/60Hz POWER CONSUMPTION (Idle/Max)Dimensions(W x D x H, grille included):Product Weight (grille iucluded):16.3″x 17.77″x 16.95″(414 x 451.3 x 430.5mm)<0.5W (standby)1180W/7.7A(max-230Vac)1230W/12.87A(max-120Vac)1190W/15.97A(max-100Vac)ABNORMAL CONDITION :LED flashing• LED flashing in red <30sec: Subwoofer is in protection mode and will recover. LED becomes green color.• LED flashing in red >30sec: Unplug/switch-off AC power till LED light off. Plug-in/switch-on AC power and subwoofer will recover. LED becomes green color.710 minutes. The subwoofer’s LED will glow green when the subwoofer is on and will glow red when the subwoofer is in Standby .E n g l i s h:JBLHDI-1200P:::::::::иа йтКEN : For additional languages, please visit FR : Pour les autres langues, veuillez visiter ES : Para obtener otros idiomas, visite DE : Informationen in weiteren Sprachen finden Sie unter RU : Если вам нужны версии на других языках, перейдите на сайт JP : 他の言語で読むには、 にアクセスしてくださいKO : 추가 언어에 대해서는 에서 확인하십시오 CHN : 如需其他语言,请访问 8HARMAN International Industries, Inc.8500 Balboa Boulevard, Northridge, CA 91329 USAPart No. 950-0564-001© 2020 HARMAN International Industries, Incorporated. All rights reserved.JBL and HDI (High Definition Imaging) are trademarks of HARMAN International Industries, Incorporated, registered in the United States and/or other countries.PolyPlas and Symmetrical Field Geometry are trademarks of HARMAN International Industries, Incorporated.Features, specifications and appearance are subject to change without notice.。
页脚内容0目录1.概述-----------------------------------------------------------------------------2 2.出厂质量证书(见原英文手册)……略3.注意事项-----------------------------------------------------------------------3 4.仪器主要特点-----------------------------------------------------------------4 5.操作5.1测量原理------------------------------------------------------------------55.2压力和流量---------------------------------------------------------------55.3建立和使用---------------------------------------------------------------65.4“零”点校准-------------------------------------------------------------65.5量程“SPAN”校准-----------------------------------------------------75.6 信号输出-----------------------------------------------------------------75.7充电-----------------------------------------------------------------------7页脚内容15.8防爆-----------------------------------------------------------------------76.维护----------------------------------------------------------------------------87.仪器常用备件表-------------------------------------------------------------88.常见故障和处理办法-------------------------------------------------------99.外观图、接线图、结构图(见原英文手册)……略10.保修服务--------------------------------------------------------------------10第一部分概述该氧分析仪是一台高精度测量仪器,可在多种应用场合为用户提供多年的可靠使用。
MG500/1200-WD滚筒式采煤机产品说明书操作人员必须进行相应的煤矿安全规程培训使用者在使用前必须认真阅读本产品说明书太原矿山机器集团有限公司2007年2月(本产品执行MT/T81、MT/T82、Q/140000TK02-2007标准的规定)目录第一章整机概述 (1)1. 机器型号 (1)2. 机器用途 (1)3. 采煤机的组成 (1)4. 采煤机的特点 (1)5. 采煤机的技术特征 (4)第二章摇臂 (6)1. 摇臂的作用 (6)2. 规格与性能 (6)3. 机器的外形图 (7)4. 工作原理与结构特征 (7)5. 注油 (11)6. 摇臂的安装调整和试运转 (11)7. 操作规程 (12)8. 轴承目录 (13)9、常见故障的分析及处理 (14)第三章牵引传动部 (15)1. 牵引传动部的用途 (15)2. 规格与性能 (15)3. 概述 (16)4. 传动系统 (16)5. 制动器 (18)6. 轴承目录 (20)7. 冷却系统 (21)8. 润滑 (21)第四章液压调高系统 (22)1. 泵站概述 (22)2. 采煤机常见故障 (28)3. 调高油缸 (34)第五章主机架 (36)1. 结构 (36)2. 特点 (36)3. 主机架的润滑 (37)第六章辅助部件 (37)1. 喷雾冷却系统 (37)2. 辅助液压系统 (39)3. 护板及拆卸工具 (40)第七章破碎机 (41)1. 破碎机的作用 (41)2. 破碎机的主要技术参数: (41)3. 破碎机的外形、结构及工作原理 (42)4. 破碎机的润滑 (44)5. 破碎机的安装、调试和试运转 (46)6. 操作规程 (46)7. 轴承目录 (47)8. 几点说明 (47)第八章截割滚筒 (47)1. 结构与作用 (47)2. 滚筒的拆卸及注意事项 (48)第九章电气系统 (49)1. 电气系统介绍 (49)2. 电气控制系统 (60)3. 电气系统操作 (74)第十章运输、操作与检修 (76)1. 运输 (76)2. 井上检查与试运转 (78)3. 解体下井运输 (78)4. 采煤机的启动、操作和停机 (79)5. 采煤机的注油 (83)6. 采煤机的维护与检修 (84)第一章整机概述1. 机器型号MG500/1200-WD滚筒式采煤机是一种多电机驱动、横向抽屉式布置,采用机载式交流变频调速装置的新型电牵引采煤机。
Eaton ELP1200IECEaton Ellipse PRO USV IEC, 1200 VA, 750 W, Eingang: C14,Ausgänge: (4) C13, (4) C13 nur Überspannung, TowerAllgemeine spezifikationEaton Ellipse PRO USV ELP1200IEC74317243795282 mm275 mm390 mm9.9 kg CE-KennzeichnungIEC/EN 62040-1 IEC/EN 62040-2 CEEAC USVProduktname Katalognummer UPC Produkt Länge/Tiefe Produkthöhe Produktbreite Produktgewicht Einhaltung(en) Zertifikat(e)Produkttyp60 Hz750 W0,6TowerNeinC14150 V284 V50 HzEaton UPS Companion (ermöglicht eine sichere Systemabschaltung, Stromverbrauchsmessung und Konfiguration der USV-Einstellungen)AuswechselbarAbgedichtet, Bleisäurebatterie97Eaton Ellipse PRO UPS 650/800/1200/1600 VA Installation and user manual (multiple languages)EU declaration of conformity Eaton Ellipse PROSekundäre Frequenz max LeistungAusg.leist.faktor FormfaktorBeinhaltet Netzwerkkarte Eingangsanschluss Eingangsspannung – min Ausgangsspannung – max Sekundäre Frequenz min Softwarekompatibilität Batteriewechsel BatterietypEffizienzBesondere Merkmale Benutzerhandbücher ZertifizierungsberichteKomfortables, extraflaches Design für eine einfache Installation in jederBüroumgebung Automatische Spannungsregelung (Automatic Voltage Regulation/AVR)HochleistungsfähigesÜberspannungsschutzgerät nach IEC 61643-11Schutz der Datenleitung, um sicherzustellen, dass die Internetleitung(einschließlich xDSL) vorÜberspannungen geschützt istLCD-Display für Echtzeitdaten zu Status und Messwerten8 Steckdosen für PC und PeripheriegeräteMit der EcoControl-Funktion sparen Sie bis zu 20 % mehr Strom als mit unterbrechungsfreie Stromversorgungen (USVs) der Vorgängergeneration HID-kompatibler USB-Anschluss (Kabel im Lieferumfang enthalten) für die automatische Integration in gängige Betriebssysteme (Windows/Mac OS/Linux) Leicht austauschbare Batterie trägt zu verlängerter Lebensdauer der USV beiBauformFreistehendes ModellAusgangsspannung – min176 VFarbeSchwarzErweiterte AkkukapazitätNoAusgangsspannungsbereich 176–284 VTopologieLine-InteractiveÜberspannungsschutzJaLaufzeit auf Halblast9 minEingangsnennspannung230 V Standard (220/230/240 V)Eingangsfrequenz-Bereich46-70 HzEingangsspannung – max285 VSpannungsartACPhase (Ausg.)1AkkumanagementWechselbare Batterien, automatischer Batterietest, Tiefentladeschutz, kaltstartfähigAutomatische AusschaltfunktionJaAnzahl der Ausgänge C138Betriebstemperatur - min0 °CVA Wert1200 VAPotentialfreier SchaltkontaktNeinSteckdosen(4) C13, (4) C13 nur ÜberspannungPhase (Ein.)1Verpackungsinhalt(2) IEC-IEC KabelUSB-KabelBedienungsanleitungSicherheitshinweise,Geräuschpegel< 27 dB bei 1 MeterEinspeisungstyp1LaufzeitgrafikAnzeige des LaufzeitgraphsBenutzeroberflächeLCD (USV-Status und -Messwerte, Konfiguration von USV-Einstellungen)Anzahl Batterien2Betriebstemperatur - max35 °CSpannung230 VTemperaturbereich0° bis 35°C (32° bis 95°F)Ethernet-SchnittstelleNeinKommunikationUSB-Port (HID-konform)Relative Luftfeuchtigkeit0-85 % ohne BetauungAusgangsscheinleistung1200 VARack-Montage-BausatzNeinAusgangsfrequenz50/60 HzLaufzeit bei Volllast2 Min.SchnittstellentypUSBPrimäre Frequenz - min46 HzBatterieleistung12 V/7 AhTypUSV-AnlageAusgangsnennspannungEaton Konzern plcEaton-Haus30 Pembroke-StraßeDublin 4, Irland© 2023 Eaton. AlleRechte vorbehalten. Eaton ist eine eingetragene Marke. Alle anderen Warenzeichen sind Eigentum ihrer jeweiligenBesitzer./socialmedia 230 V Standard (220/230/240 V)Nein165–285 V (einstellbar auf 150–285 V)50/60 Hz70 Hz2000 mErweiterungssteckplätzeEingangsspannungsbereichNennfrequenzPrimäre Frequenz - maxHöhe。
• • • •• • • • • • • ••P1200系列高性能金属应变式压力传感器产品说明抗恶劣环境设计高破坏压力高可靠性低或高电平输出 P1200系列压力传感器和变送器能够对液体和气体压力进行高精度地测量。
这些传感器运用高可靠性的应变感测技术和稳定耐高温的电子器件,可以在广泛的温度范围内正常工作。
P1200采用17-4PH不锈钢,可在外部极端恶劣的环境中提供优越的比能。
在温度补偿范围-20℃到80℃之内,可以保证P1200的准确度在±0.20%F.R.O以内。
P1200具有电缆线或接插件输出两种类型,可以提供多种输出电信号,包括0~20mV,0~1OOmV,0~5V、0~1OV和4~20mA。
多个可选压力输人端口,能够适应大多数的应用要求。
压力范围从0~75Psi到10,000Psi(0~5Bar到700Bar),压力参考有绝压、密封表压和通气表压三种选项。
PI200系列能承受大于20倍压力量程的破坏压力和提供5倍压力量程的过压保护,不会因为过压而损坏传感器。
特点应用高精度:<±0.15F.R.O电缆/接插件输出端口不锈钢结构5倍过载压力高或低电平输出车辆制动系统监视气体生产农业机械液压控制1000 to 1600 - - --1012 12 25 -6, 10, 16, 25, 40, 60, 100, 160, 250, 400, 600-65°F to 185°F (-54°C to 85°C) [P1221/4 -65°F to 250°F (-54°C to 120°C)] -4°F to 185°F (-20°C to 85°C) [P1221/4 -4°F to 212°F (-20°C to 100°C)] -65°F to 250°F (-54°C to 120°C) <±0.010% F.R.O./°F (±0.02% F.R.O./°C) -4° to 185°F (-20°to 85 °C ±1.2% ±2.0%性能参数通用标准10VDC (12 V max) 10VDC (12 V max) 10VDC (12 V max) P1221/3 P1231/3 P1241/3P1261/3 P1281/3 1000 ±50<10 <10 <10系列产品型号输入电压输入阻抗(Ω)输入电流(mA)满量程输出(±2%)输出阻抗输出电流(mA)响应频率零位误差(%F.R.O)重量(OZ/克)20mV 100mV 5VDC 5VDC 4-20 mA (16 mA±2%)1300Ω(36V)<±2 <±2 <±2 <±2 4.0 mA +2-0 - -5 5 - 18-32VDC10-36VDC3.4 (95)4.4 (125)4.4 (125)4.4 (125)4.4 (125)2.5 to 40 kHz2 kHz 2 kHz 1 kHz 1 kHz P1200P1230P1240P1260 P1280 压力范围高压(Psi) (Bar)中压(Bar)参考压力压力极限破坏压力压力介质非线性、迟滞和重复性综合误差温度工作温度补偿温度储存温度湿度接插件输出型电缆输出型抗冲击抗振动EMC绝缘电阻温度误差(包括零点和满量程输出误差)总不确定度(包括非线性,迟滞,重复性及温度误差) 0-75, 100, 150, 220, 250, 350, 500, 750, 1000, 1500, 2200, 2900, 3500, 5000, 7500,10000 0-5, 7, 10, 15, 20, 25, 35, 50, 70, 100, 150, 200, 250, 350, 500, 700 通气表压,密封表压和绝压,依特殊订购而定。
Powerline 1200 + Extra Outlet Model PLP1200Package ContentsIn some regions, a resource CD is included with your product.Getting StartedPowerline adapters provide an alternative way to extend your network using your existing electrical wiring. Plug 2 or more Powerline adapters into electrical outlets to create a wired network connection. You can add up to 16 Homeplug AV-certified and AV2-certified adapters to extend your network. For a complete list of Homeplug AV-certified devices, visit /certified_products.Meet Your AdapterBefore you install your adapter, familiarize yourself with its LEDs,buttons, and port.Ethernet port Security buttonFactory Reset buttonPower LEDEthernet LEDPick A Plug LEDPower LEDGreen . The electrical power is on.Amber . The adapter is in power saving mode.Blinking green . The adapter is in the process of setting up security.Off . The adapter is not receiving electrical power.Ethernet LEDLit . The Ethernet port is linked.Off . No Ethernet connection is detected.Pick A Plug LEDThe Pick A Plug feature lets you pick the electrical outlet with the strongest performance, indicated by the color displayed by the LED:Red . Link rate < 50 Mbps (good).Amber . Link rate > 50 and < 80 Mbps (better).Green . Link rate > 80 Mbps (best).Off . The adapter did not find any other compatible Powerline devices using the same encryption key.Factory Reset button Press the Factory Reset button for one second, then releaseit to return the Powerline adapter to its factory default settings.Ethernet port Use an Ethernet cable to connect your wired devices,including computers, WiFi routers, or game consoles, to yourPowerline network.Security button Use the Security button to create a secure Powerlinenetwork.Install Your AdaptersRoom 1Room 2Secure Your Network¾To create a secure network:1. Plug in your new adapters.2. Wait until the Pick A Plug LEDs are blinking.3. Press the Security button on one of the adapters for two seconds,then press the Security button on one of the other adapters in your existing network for two seconds.Both buttons must be pressed within two minutes.4. If you are installing additional adapters, repeat Step 3 with one of thesecure adapters and one of the adapters that is not yet secured. Note: The Security button does not work in power saving mode (see Troubleshooting Tips on page 10).Warning: Do not press the Security button on the Powerline adapter until installation is complete and the adapters are communicating with each other (indicated by the blinking Power LED). Pressing this button too soon can temporarily disable Powerline communication. If this occurs, use the Factory Reset button to return the Powerline adapter to its factory default settings.Add AdaptersTo add adapters before you configure the security feature, just plug them in and connect the adapters to your equipment.¾To add adapters to a Powerline network with security set:1. Plug in and connect the new adapters.2. On any of the adapters that are already a part of the secure network,press and hold the Security button for two seconds.3. On the new adapter, press and hold the Security button for twoseconds.Both buttons must be pressed within two minutes.Troubleshooting TipsPower LED is off.Make sure that power is supplied to the electricaloutlet, and that the Powerline devices are not pluggedinto an extension cord, power strip, or surge protector.Power LED is blinking amber.Power saving mode occurs when the Ethernet LED is off. This can occur in the following circumstances:• The Ethernet cable is unplugged.• The device connected through the Ethernet cable is turned off.• The adapter is idle for 10 minutes.It returns to normal mode within two secondsafter the Ethernet link is up.Pick A Plug LED is off.• If you already set network security, make surethat all Powerline devices are using the sameencryption key. See the online user manual fordetails.• Press the Factory Reset button on each devicefor one second to return the Powerline adapter toits factory default settings.Pick A Plug LED is amber or red.Something is interfering with communication between adapters. To resolve this, do the following:• Move the adapter to another outlet.• Unplug devices that might be causing interference such as surge suppressors and items with motors.Ethernet LED is off.• Make sure that the Ethernet cables are workingand securely plugged into the devices.• Press the Factory Reset button on each devicefor one second to return the Powerline adapter toits factory default settings.11201-19271-01May 2015NETGEAR, Inc.350 East Plumeria DriveSan Jose, CA 95134, USA SupportThank you for purchasing this NETGEAR product. After installing your device, locate the serial number on the label of your product and use it to register your product at https:// . You must register your product before you can use NETGEAR telephone support. NETGEAR recommends registering your product through the NETGEAR website.For product updates and web support, visit .NETGEAR recommends that you use only the official NETGEAR support resources. You can get the user manual online at or through a link in the product’s user interface.Trademarks© NETGEAR, Inc., NETGEAR and the NETGEAR Logo are trademarks of NETGEAR, Inc. Any non-NETGEAR trademarks are used for reference purposes only.ComplianceFor the current EU Declaration of Conformity, visit /app/answers/detail/a_id/11621/.For regulatory compliance information, visit /about/regulatory/.See the regulatory compliance document before connecting the power supply.。
Powerline 1200 Model PL1200Package ContentsIn some regions, a resource CD is included with your product.Getting StartedPowerline adapters give you an alternative way to extend your network using your existing electrical wiring. Plug two or more Powerline adapters into electrical outlets to create a wired network connection. You can add up to 16 Homeplug AV-certified and AV2-certified adapters to extend your network. For a complete list of Homeplug AV-certified devices, visit /certified_products.Power LED Factory Reset button Ethernet port Pick A Plug LEDEthernet LEDSecurity buttonMeet Your AdapterBefore you install your adapter, familiarize yourself with its LEDs, buttons, and port.Power LEDGreen . The electrical power is on.Amber . The adapter is in power saving mode.Blinking green . The adapter is in the process of setting up security.Off . The adapter is not receiving electrical power.Ethernet LEDLit . The Ethernet port is linked.Off . No Ethernet connection is detected.Pick A Plug LEDThe Pick A Plug feature lets you pick the electrical outlet with the strongest performance, indicated by the color displayed by the LED:Red . Link rate < 50 Mbps (good). Amber . Link rate > 50 and < 80 Mbps (better).Green . Link rate > 80 Mbps (best).Off . The adapter did not find any other compatible Powerline devices using the same encryption key.Factory Reset button Press the Factory Reset button for one second, then releaseit to return the Powerline adapter to its factory default settings.Ethernet port Use an Ethernet cable to connect your wired devices,including computers, WiFi routers, or game consoles, to yourPowerline network.Security button Use the Security button to create a secure Powerlinenetwork.Install Your AdaptersRoom 1Room 2Secure Your Network¾To create a secure network:1. Plug in your new adapters.2. Wait until the Pick A Plug LED is lit.3. Press the Security button for two seconds, then press the Securitybutton on one of the other adapters in your existing network for two seconds. Both buttons must be pressed within two minutes.Note: The Security button does not work in power saving mode (see Troubleshooting Tips on page 10).Warning: Do not press the Security button on the Powerline adapter until installation is complete and the adapters are communicating with each other (indicated by the blinking Power LED). Pressing this button too soon can temporarily disable Powerline communication. If this occurs, use the Factory Reset button to return the Powerline adapter to its factory default settings.Note: If you want to add another adapter after creating a secure Powerline network, perform a factory reset on all of the adapters and then perform this procedure.Add AdaptersTo add adapters before you configure the security feature, just plug them in and connect the adapters to your equipment.¾To add adapters to a Powerline network with security set:1. Plug in and connect the new adapters.2. On all of the previously installed adapters, press and hold the FactoryReset button for one second.This returns them to the factory settings.3. Secure the Powerline network:a. On any of the adapters, press and hold the Security buttonfor two seconds.b. On any one of the other adapters, press and hold theSecurity button for two seconds.Both buttons must be pressed within two minutes.Troubleshooting TipsPower LED is off.Make sure that power is supplied to the electricaloutlet, and that the Powerline devices are not pluggedinto an extension cord, power strip, or surge protector.Power LED is blinking amber.Power saving mode occurs when the Ethernet LED is off. This can occur in the following circumstances:• The Ethernet cable is unplugged.• The device connected through the Ethernet cable is turned off.• The adapter is idle for 10 minutes.It returns to normal mode within two secondsafter the Ethernet link is up.Pick A Plug LED is off.• If you already set network security, make surethat all Powerline devices are using the sameencryption key; see the online user manual fordetails.• Press the Factory Reset button on each devicefor one second to return the Powerline adapter toits factory default settings.Pick A Plug LED is amber or red.Something is interfering with communication between adapters. To resolve this:• Move the adapter to another outlet.• Unplug devices that might be causing interference such as surge suppressors anditems with motors.Ethernet LED is off.• Make sure that the Ethernet cables are workingand securely plugged into the devices.• Press the Factory Reset button on each devicefor one second to return the Powerline adapter toits factory default settings.11January 2015NETGEAR Inc.350 East Plumeria DriveSan Jose, CA 95134, USA SupportThank you for purchasing this NETGEAR product. After installing your device, locate the serial number on the label of your product and use it to register your product at https:// . You must register your product before you can use NETGEAR telephone support. NETGEAR recommends registering your product through the NETGEAR website.For product updates and web support, visit .NETGEAR recommends that you use only the official NETGEAR support resources. You can get the user manual online at or through a link in the product’s user interface.Trademarks© NETGEAR, Inc. NETGEAR, and the NETGEAR Logo are trademarks of NETGEAR, Inc. Any non NETGEAR trademarks are used for reference purposes only.ComplianceFor the current EU Declaration of Conformity, visit /app/answers/detail/a_id/11621/.For regulatory compliance information, visit /about/regulatory/.See the regulatory compliance document before connecting the power supply.。
Powerful Mainstream Solution For Modern BusinessesIAP1200KEY FEATURES•802.11ac High Speed Dual -Band: IEEE 802.11ac concurrent dual-band with 1200Mbps wireless speed.•Easy Installation: In-wall design with easy installation kit. •Compact Housing: Ultra slim design.•Designed for High Density BYOE Usage: Ideal for crowded environments and BYOE (Bring Your Own Everything) workplace Wi-Fi connection.•Multiple SSIDs for Security Management: Supports up to 32 SSIDs (16 x 2.4GHz & 16 x 5GHz) ideal for multiple departments, user groups, customers or guests.•Wide Coverage & High Sensitivity: Adjustable RF output power and high receiver sensitivity for wide coverage across large spaces.•Seamless Mobility: 1.5 x greater coverage than typical APs for blanket coverage to ensure seamless connectivity for Wi-Fi devices across enterprise environments. •Power over Ethernet: Supports IEEE 802.3af PoE.•Built -In RADIUS Server: With management for up to 256 user accounts.•Business Environments : Mainstream choice for SMBs. Suitable for a wide range of commercial applications such as offices, hotels, MDUs (Multi-Dwelling Units), airports, meeting rooms, schools, campuses etc.•Central Management: Edimax Pro Network Management Suite (NMS) for easy and intuitive web-based central management. AP built-in with NMS supports AP array architecture.2 x 2 AC1200 Dual-Band In-Wall PoE Access PointThe IAP1200 is a powerful wireless solution designed to meet the needs of modern mainstream businesses. With the latest IEEE 802.11ac technology for wireless speeds up to 1200Mbps, the stylish in-wall design is specifically for existing building structures so you can easily change an existing in-wall wired Ethernet jack to a wireless access point. Ideal areas of deployment include offices, hotels, MDUs (Multi-Dwelling Units), airports, meeting rooms, schools, campuses etc.For hotels which demand security, flexibility and speed, the IAP1200 provides guests with a convenient wireless LAN service. With standard US or EU type Ethernet wall jacks already installed, there’s no need for extra time and cost to deploy a wireless network – you can reduce re-wiring costs while blending the AP with the interior décor. And the high-density capacity is ideal for BYOE workplaces or other environments with a high volume of users and wireless devices. Multiple SSIDs can be configured for different departments or user groups and a built-in RADIUS server provides additional verification. Additionally featuring Power over Ethernet support (PoE) and an intuitive web-based management interface – which provides flexibility for deployment and extensive management options for company MIS departments and network administrators.When performance and security are critical for yourbusiness, you need products that are engineered for your industry. The Edimax Pro series is designed to help your business and provide the connectivity that you rely on every day, with safety and effectiveness guaranteed.Central Management & PoE (Power over Ethernet) GigabitIAP12002.4GHz2D Radiation Pattern @ Vertical 5GHz2D Radiation Pattern @ Vertical 2.4GHz2D Radiation Pattern @ Horizontal 5GHz2D Radiation Pattern @ HorizontalHotel Guest Room-IAP In-Wall AP Easy Deployment -In-Room Dual-Band -AC1200 High Speed -PoE Gigabit-Easy Centralized ManagementIn-Wall Dual-BandAC12002.4GHz5GHzInternet24-Port Gigabit PoE Switch APC500 AP Controller Centralized & Easy ManagementPoE GigabitPoE GigabitSSID = GuestSSID = StaffCentral Network Management: NMSWork with Edimax Pro NMS (Network Management Suite)* web-based wireless network management software. Company MIS administrators can plan and manage Edimax Pro access points’ powerful functionalityaccording to their office space using an easy, remote web-based interface which includes a dashboard, map view, traffic statistics and wireless client list for network-wide remote administration. RADIUS settings, WLAN group settings, access control, guest network settings and firmware upgrades can all be managed centrally from a single location to reduce network downtime, aid troubleshooting and optimize network performance.Graphical zone plans with Google Maps integration and setup wizards are also available for expanding and managing large networks with multiple access points, with custom floor plans, visual overviews and easy drag-and-drop icons for quick access to key performance and monitoring information.*NMS is built-in with Edimax Pro CAP, WAP series & OAP1750 access point.IAP1200 Ideal areas of deployment include offices, hotels, MDUs (Multi-Dwelling Units), airports, meeting rooms, schools and campuses.Easy Installation3-Step Easy InstallationConnect an RJ45 LAN cable to the IAP1200’s rear PoE LAN port.Screw the IAP1200 securely onto the wall.Attach the wall plate to theIAP1200.Campus OfficeHotel AirportHardware LAN Interface Giga x 2, RJ11 x 2 PoE 802.3af (Supports 802.3at) Antenna Type: 2 x Built-In PIFAGain: 2.14dBi (2.4GHz), 3.8dBi (5GHz) Max.Power802.3af (Support 802.3at)Dimensions (L x W x H)Faceplate Set : 70 x 115 x10mm (US-Type ) Faceplate Set : 86 x 86 x10mm (EU-Type ) Stand/Mounting Bracket : 48.5 x 74 x 38mmWeight 125gPowerConsumption (Full Loading) 8WMounting In-wall Reset YLED Indicator 1. Power LED 2. Diag LEDEnvironmental Conditions Operating Temperature: 0°C (32°F) to 40°C (104°F) Storage Temperature: -20°C (-4°F) to 60°C (140°F)Operating Humidity: 90% or Less Storage Humidity: 90% or LessPower Saving 802.3az Internal Buzzer YHousing Flammability Rating PlasticWireless Standard802.11 a/b/g/n/ac Concurrent Dual-BandNo. of Radios2 Receiver Sensitivity ≤ -91dBm CertificationCE/FCCNumber of SSIDs 16 (2.4GHz) + 16 (5GHz)Performance Maximum Data Speed300 + 867Mbps Concurrent Clients Up to 50 Per Radio Security Encryption WEP / WPA / WPA2Wireless L2 IsolationY Station Isolation Y IEEE 802.1x AuthenticatorY EAP Authentication PEAP Hidden SSIDY MAC Address Filter Y Wireless STA Y Rogue APDetection (w/NMS) YSoftwareWireless Mode AP / WDS AP / WDS Bridge802.1q VLAN Y (VID = 1-4095)Spanning Tree RSTPQoSWMM (802.11e)Max Associated Station No. Pass-Through IPv6 and VPN (PPTP, L2TP/IPsec)DSCP (802.1p)YMulticast Rate up to 54MbpsYMaximum performance, actual data rates, and coverage will vary depending on network conditions and environmental factors. Product specifications and design are subject to change without notice.Copyright © 2017 Edimax Technology Co. Ltd. All rights reserved.IAP1200SPECIFICATIONS2 x 2 AC Dual-Band In-Wall PoE Access PointRF SpecificationsFrequency Band•Radio Ⅰ: 802.11b/g/n 2.412~2.484(GHz) •Radio Ⅱ: 802.11a/n/ac5.18~5.24(GHz), 5.745~5.825(GHz)(The supported frequency band is restricted by local regulations.)Operation Channels•2.4GHz : US/Canada 1-11; 2.412~2.462GHz Europe 1-13; 2.412~2.472GHz Japan 1-14; 2.412~2.484GHz •5GHz : Country dependent for the following ranges:US/Canada: Band 1:36, 40, 44, 48; 5.180~5.240(GHz)Band 4:149, 153, 157, 161, 165; 5.745~5.825(GHz)Europe: Band 1:36, 40, 44, 48; 5.745~5.825(GHz) Transmit Power802.11b10dBm@1Mbps 10dBm@2Mbps ************* 10dBm@11Mbps 802.11g10dBm@6Mbps 10dBm@9Mbps 10dBm@12Mbps 10dBm@18Mbps 10dBm@24Mbps 10dBm@36Mbps 10dBm@48Mbps 10dBm@54Mbps 802.11n (2.4G)10dBm@MCS0/MCS8 10dBm@MCS1/MCS9 10dBm@MCS2/MCS10 10dBm@MCS3/MCS11 10dBm@MCS4/MCS12 10dBm@MCS5/MCS13 10dBm@MCS6/MCS14 10dBm@MCS7/MCS15802.11a10dBm@6Mbps 10dBm@9Mbps 10dBm@12Mbps 10dBm@18Mbps 10dBm@24Mbps 10dBm@36Mbps 10dBm@48Mbps 10dBm@54Mbps 802.11n(5G)10dBm@MCS0/MCS8 10dBm@MCS1/MCS9 10dBm@MCS2/MCS10 10dBm@MCS3/MCS11 10dBm@MCS4/MCS12 10dBm@MCS5/MCS13 10dBm@MCS6/MCS14 10dBm@MCS7/MCS15 802.11ac10dBm@MCS0 10dBm@MCS1 10dBm@MCS2 10dBm@MCS3 10dBm@MCS4 10dBm@MCS5 10dBm@MCS6 10dBm@MCS7 10dBm@MCS8 10dBm@MCS9 Receiver Sensitivity802.11b≤-91dBm@1Mbps ≤-87dBm@11Mbps 802.11g≤-90dBm@6Mbps ≤-71dBm@54Mbps 802.11n (2.4G) ≤-87dBm@MCS0 ≤-68dBm@MCS7 ≤-85dBm@MCS8 ≤-65dBm@MCS15802.11a≤-90dBm@6Mbp ≤-71dBm@54Mbps 802.11n(5G)≤-86dBm@MCS0 ≤-69dBm@MCS7 ≤-84dBm@MCS8 ≤-65dBm@MCS15 802.11ac≤ -82dBm@MCS0 ≤ -63dBm@MCS9 ≤ -83dBm@MCS10 ≤ -55dBm@MCS19ManagementDeploymentStandalone (AP Mode)Managed AP mode: Managed by AP Controller(APC500), Edimax Pro Master AP with NMS softwareConfiguration HTTP/HTTPSSNMP v1, v2c, v3 CLI (Telnet, SSH)RADIUS Server Built-In Auto-Channel Y Private MIB YPackage ContentsAccess PointAC1200 In-Wall PoE Access PointMounting Bracket In-Wall-Mount Bracket KitQuick Installation GuidePrinted English Quick Installation GuideRJ45 Gigabit LAN PortRJ11 Pass-Through Telephone Port RJ45 Gigabit PoE LAN PortReset Button LEDs。
目次1装置简介 (1)1.1 装置型号及功能配置 (1)1.2 保护软件名称及功能配置 (1)1.3 装置特点 (3)2技术参数 (5)2.1额定参数 (5)2.2 主要技术性能 (5)2.3 绝缘性能 (6)2.4 抗电磁干扰性能 (7)2.5 机械性能 (8)3装置硬件 (9)3.1 机箱结构 (9)3.2 主要模件设计 (9)3.3 对外通讯接口 (9)4 保护原理 (10)4.1 差动保护1(SOFT-CD1) (10)4.2 差动保护2(SOFT-CD2) (13)4.3 差动保护3( SOFT-CD3) (15)4.4 后备保护 (16)4.5 数据记录 (23)5 与变电站自动化系统配合 (25)6 定值及整定说明 (26)6.1 各相定值的调整级差 (26)6.2 SOFT-CD1差动保护定值…………………………………………………。
(26)6.3 SOFT-CD2差动保护定值 (28)6.4 SOFT-CD3差动保护定值 (29)6.5 SOFT-HB1后备保护定值 (30)6.6 SOFT-HB2后备保护定值 (32)6.7 SOFT-HB4后备保护定值 (34)1 装置简介PST-1203数字式变压器差动保护装置及PST-1204A后备保护装置是以差动保护、后备保护为基本配置的成套变压器保护装置,适用于500kV、330kV等大型电力变压器。
本系列数字式变压器保护装置有两种不同原理的差动保护。
本系列保护装置基本配置设有完全相同的CPU插件,分别完成差动保护功能,高压侧后备保护功能, 中压侧后备保护功能,低压侧后备保护功能,各种保护功能均由软件实现。
保护的逻辑关系符合国家设计原则。
本系列数字式变压器保护装置的保护配置和各保护时限的跳闸逻辑可在线编程。
1.1 装置型号及功能配置1.1.1 PST-1203本保护装置为差动保护单机,包括差动保护1(SOFT-CD1);差动保护2(SOFT-CD2);差动保护3(SOFT-CD3);适用于500kV~330kV电压等级的变压器。