Liquid Chlorine evaporator Caustic truck The End see you! Element Cathode of the bipolar element is flexible and impact the membrane with anode side The voltage detector of each element Safety equipment Ammonia for Cl2 leakage detecting Sulfuric acid feed tank and spent acid tank Cl2 absorbers Hypo recycle and analyzer Redox analyzer of sec.absorber : 46 mv Top caustic tank and vent gas to ATM Introduction to Chlor-Alkali Plant Cooling drying and absorption Cell room compressor workshop Control room 24 electrolyzers in the cell room, in 12 rows. And two separate anolyte and catholyte system. Anolyte and catholyte feed Anolyte vessel and heat exchanger On-line analyzer cabin Cl2 cooling and drying system Cl2 from cellroom to coolers Cl2 to primary cooler and demister, then to Cl2 blower blow to secondary cooler and demister ,then to drying column and demister Cl2 and anolyte outlet Anolyte feed H2 and caustic outlet Catholyte feed The chlorine separator Cl2 and anolyte separator Cl2 to absorbers Cl2 to wet Chlorine header Safety equipment Fan is on when disassembling the electrolyzer Chlorine purity sample equipment Cell room housekeeping Demin water should be used to flush the ground for safety. Plant water can be conductible and dangerous. Lub mpressor coolers Chlorine compressor area Cl2 leakage detectors Chlorine compressor anti-surge valve Liquid Cl2 surge tank and NCl3 vaporizer N2 to compressor for startup Chlorine compressor(4 stage) Chlorine compressor Siemens motor Gear box Chlorine compressor coupling N2 purge for seal Lube Oil return 24”butterfly valve to compressor suction. When the compressor is recycling during startup , the butterfly valve should be open slowly to avoid rapidly pressure drop in the cell room . Chlorine compressor cooling water system Cooling water pH: 7.41 Air hose connect to aerophore for emergency use Air gas pot Liquid Chlorine storage Liquid Chlorine storage The electricity system Busbar from transformer The transformer and rectifier with cooling water supply The bus bar Dangerous to touch ! Isolation The anode and the cathode outlet and feed manifold piping Electrolyzer assembly 1 Electrolyzer assembly 2 Electrolyzer assembly 3 Electrolyzer assembly 4 Electrolyzer assembly 5 Element A pinhole on the membrane let Cl2 enter cathode to damage elements