电动机保护CK200说明书
- 格式:pdf
- 大小:397.71 KB
- 文档页数:10
Electric Knife Model GEK200 OPERATING INSTRUCTIONSGEK200: 220-240V, 50Hz, 100WGENERAL CARE AND SAFETY GUIDEPlease read all instructions carefully before using this appliance and keep them for future reference .Thank you for choosing this GOLDAIR Electric Knife.This GOLDAIR appliance has been designed and manufactured to the highest standard and with proper use and care,as described in this leaflet,will give you years of useful service.Please read these instructions carefully.ALWA YS✔Always ensure hands are dry before handling the plug or the Electric Knife✔Always operate the Electric Knife on a secure,dry,level surface.✔Always allow adequate air space above and on all sides for air circulation.Do not allow the Electric Knife to touch clothing,dishtowels or other items during use.Do not use under cupboards.✔Always be sure to unplug from the socket when not in use and before cleaning.✔Always allow the Electric Knife to cool before cleaning and storing.✔Carry out regular checks of the supply cord to ensure no damage is evident.✔Return the Electric Knife after a malfunction,or if it has been damaged in any manner to an authorised service technician for examination,repair or adjustment as special purpose tools are required.✔Switch off the appliance and disconnect from supply before changing accessories or approaching parts that move in use.NEVER✘Never touch hot surfaces.✘Never use this appliance outdoors.✘Never use this appliance for any purpose other than its intended use.This appliance is for household use only.✘This appliance is not intended for use by persons (including children)with reduced physical,sensory or mental capabilities or lack of experience and knowledge,unless they are supervised or have been given instruction concerning the use of the Electric Knife by a person responsible for their safety.✘Close supervision is necessary when the appliance is near children.✘Never leave the appliance unattended.✘Never allow the power cord to overhang the edge of a table or bench top or touch any hot surface.✘Never place this appliance on or near a hot gas or electric burner or where it could touch a heated oven or microwave oven.✘Never immerse the Electric Knife cord set or plug in water or any other liquid to protect against electrical hazards.✘Never place the Electric Knife body in a dishwasher.✘Never operate the appliance with a damaged cord or plug,after it malfunctions,or if it has been damaged in any manner.✘The Electric Knife is not intended to be operated by means of an external timer orseparate remote-control system.The use of an extension cord is not recommended.DO NOT OPERATE THE ELECTRIC KNIFE FOR MORE THAN 9 MINUTES AT A TIMECOMPONENTSPLEASE KEEP THIS MANUAL FOR FUTURE REFERENCEOPERATING YOUR ELECTRIC KNIFECAUTION: The cord must be unplugged before inserting or removing blades.1.Before first use, wash the blades in hot, soapy water or in the dishwasher. Rinse and dry thoroughly. Slip the rivet at the tip of one blade into the Keyhole slot on other.2.When inserting or removing blades, always be sure the cord is unplugged.3.With the cutting (serrated) edge facing AWAY from your hand, grab the blades by the finger grips and insert the two ends of the blades into the slots of the handle. Theblades will “click” into place. Plug the cord into an electrical outlet. Position the food to be sliced on a cutting board.4.Press the power switch and guide the knife blades down through the food.CAUTION: NEVER place your hand over the blade to support it while operating this knife.The blades are designed to slide back and forth for cutting.REMOVING BLADESTo remove the blades you must unplug the cord first. Press the blade release button and grasp the blades by the finger grips with the cutting edge facing AWAY from your hand and pull out away from the handle.CAUTION:THE ELECTRIC KNIFE MAY BECOME HOT DURING OPERATION. DO NOT OPERATE THE ELECTRIC KNIFE FOR MORE THAN 9 MINUTES AT A TIME.Handle BodyFinger GripsBladesPower ButtonEject ButtonCARE AND CLEANING1.Before cleaning any part of the electric knife. Unplug the cord, and remove theblades.2.Knife blades may be washed in hot soapy water or in the dishwasher. Dry all partsthoroughly before next use.3.The knife handle and cord may be cleaned with a damp cloth. DO NOT use anyabrasive cleanser or material to clean any part of the knife as it may harm the finish.Do not put the knife handle in waterAFTER SALES SERVICEThis appliance is built to the very highest of standards.There are no user-serviceable parts.Follow these steps if the unit fails to operate:•Check instructions have been followed correctly.•Check mains supply is functional.If the appliance will not operate,return the appliance to the place it was purchased with your receipt for a replacement.SUPPORT AND TECHNICAL ADVICENorth Shore City, Auckland, New ZealandMonday –Friday 8am-5pmPhone: 0800 232 633Website: Your GOLDAIR product has been inspected and tested and is guaranteed subject to the following for a period of two years from the date of purchase against defects in workmanship and materials.During this period,such defects will be rectified by repair or replacement of the product purchased.Your product contains no user serviceable components and this warranty becomes invalid if in our opinion the product has been misused,abused,incorrectly installed,tampered with,connected to an electrical supply not corresponding with the name plate specification,or subjected to power surges.The warranty does not include any labour or other associated expense that may be involved in removal or installation of the product.Normal wear and tear is expressly excluded.If your GOLDAIR product fails to operate satisfactorily,please return it to the retailer from whom it was purchased.To obtain a repair or replacement product under this warranty,you will need to produce satisfactory evidence of date of purchase.The completed warranty and purchase receipt must be presented with the product.The warranty should be filled out at the time of purchase.It is in your interest to make sure this is done.If the product is to be replaced (cannot be repaired)then that replacement will be of the faulty product or accessory excluding packaging,instruction card etc.Where a replacement product is supplied,this shall be guaranteed for the balance of the original warranty period.Any model that is no longer available will be replaced by a model of a value and with such features as we consider appropriate in the circumstances.Goldair Ltd is not responsible for freight forwarding charges,losses or damage in transit.If service is required after the warranty period has expired,the product should be returned to a qualified electrical technician.Service outside of the warranty period will be at your cost.Consumers Guarantee Act (1993).In accordance with the above act consumers are advised that:The manufacturer does not undertake repair facilities and parts are necessarily available for this product.If any of the provisions of the foregoing are contrary to any relevant legislation,then that provision shall be deemed to be excluded from the warranty and the rest of the provisions will continue to apply.T W O Y E A R W A R R A N T YIMPORTANT: PLEASE RETAIN THIS WARRANTY CARDNAME: .ADDRESS: .PURCHASED FROM:.SUBURB:.DATE OF PURCHASE:.NAME OF PRODUCT: .MODEL No:.。
版权声明版权声明本文档版权属青岛汉泰电子有限公司所有。
青岛汉泰电子有限公司保留对此文件进行修改而不另行通知之权利。
青岛汉泰电子有限公司承诺所提供的信息正确可靠,但并不保证本文件绝无错误。
请在使用本产品前,自行确定所使用的相关技术文件规格为最新有效的版本。
若因贵公司使用青岛汉泰电子有限公司的文件或产品,而需要第三方的产品、专利或者著作等与其配合时,则应由贵公司负责取得第三方同意及授权。
关于上述同意及授权,非属本公司应为保证之责任。
HTM200用户手册2目录目录版权声明 (2)目录 (3)常规安全事项概要 (6)一般安全总结 (6)安全术语和符号 (6)产品报废处理 (7)简介 (8)型号 (8)1. 一般操作 (9)1.1 使用前检查 (9)1.1.1 检查运输包装 (9)1.1.2 检查整机 (9)1.1.3 检查随机附件 (9)1.2 充电 (9)1.3 电池的存放和更换 (9)1.3.1 电池存放 (9)1.3.2 电池更换 (10)1.4 安全锁孔使用 (12)1.5 调整支架 (13)2. 快速入门 (14)2.1 前面板介绍 (14)2.2 用户界面 (15)2.3 接口 (17)2.3.1 测试接口 (17)2.3.2 外部接口 (17)3. 功能介绍 (19)3.1 开机 (19)3.2 测量列表 (19)3.3 测量棒图 (19)3.4 通道配置 (20)3.5 系统设置 (21)3.5.1 用户 (21)3.5.2 文件 (21)3.5.3 服务 (23)3.6 固件升级 (23)HTM200用户手册3目录3.7 错误代码说明 (25)4. 数据通信接口 (26)4.1 USB连接 (26)4.2 蓝牙连接 (26)4.3 网络连接 (26)5. Android应用程序使用 (27)5.1安装应用程序 (27)5.2 应用程序简介 (28)5.2.1 主界面介绍 (28)5.2.2 设置界面介绍 (29)6. Windows软件使用 (33)6.1 软件下载 (33)6.2 软件安装 (33)6.3 软件使用 (34)6.3.1 用户界面 (34)6.3.2 文件保存 (34)6.3.3 连接方式 (35)6.3.4 记录 (37)6.3.5 显示 (37)6.3.6 快捷按钮 (38)6.3.7 通道设置 (39)7. SCPI远程控制 (40)7.1 仪器连接 (40)7.2 SCPI 命令简介 (41)7.2.1 命令格式 (41)7.2.2 符号说明 (42)7.2.3 命令缩写 (42)7.3 指令参考 (42)7.3.1 IDN子系统 (42)7.3.2 OUTPut 子系统 (42)7.3.3 TEMPerature 子系统 (43)7.3.4 MEASure 子系统 (44)7.3.5 THERmocouple 子系统 (45)8.故障处理 (46)9. 日常保养和清洁 (47)9.1 日常保养 (47)9.2 清洁 (47)10. 技术规格 (48)HTM200用户手册4目录10.1 技术指标 (48)10.2 测量精度 (49)11. 附件 (50)HTM200用户手册5常规安全事项概要HTM200用户手册 6常规安全事项概要一般安全总结仔细阅读下列安全性预防措施,以避免受伤,并防止损坏本产品或与本产品连接的任何产品为避免可能的危险,请务必按照规定使用本产品。
诚科ck—200温控器说明书
诚科CK-200温控器是一款智能数字式温度控制器,适用于各类加热、制冷、恒温等控制场合。
以下是它的部分说明:
一、外观和安装
1.外观尺寸:48mm*48mm,安装孔尺寸为45mm*45mm。
2.本产品外部接线方法为插接式连接,接线用电缆极数必须与控制器标号相符。
3.安装时,应保证空气流通,不得长时间在高温或高湿的环境下使用,以免影响控制器寿命。
二、性能特点
1.数字化调节,温度控制精度高,误差小。
2.采用双 LED 数码管进行温度实时显示,直观明了。
3.控制器具有超温及断电记忆功能。
4.控制器具有供电电压保护功能。
5.支持多种控制模式,包括PID控制模式、ON/OFF控制模式等。
6.支持多段设定功能,可以按照时间段设定多组温度值,灵活易用。
7.控制器具有自校准功能,可以自动检测并修正系统误差,保证控制精度。
三、操作指南
1.开机后,按下SET键,进入参数设定状态。
2.根据需要设定温度值、控制模式、控制器输出模式、多段控制等参数。
3.设定完成后,按下SET键保存并退出设定状态。
4.按下RUN/STOP键,即可开始温度控制。
控制器将根据设定的参数进行控制,并实时显示温度值。
5.如需修改设定参数,可再次按下SET键进入设定模式。
以上是诚科CK-200温控器的部分说明,如需更详细内容,建议查看产品说明书。
DOWNFLEX 200/400IM100131RYHPEHU , 2011Safety Depends on YouLincoln arc welding and cutting equipment is designed and built with safety in mind. H owever,your overall safety can be increased by proper installation ... and thoughtful operation on your part.DO NOT INSTALL,OPERATE OR REPAIR THIS EQUIPMENT WITHOUT READ-ING THIS MANUAL AND THE SAFETY PRECAUTIONS CON-TAINED THROUGHOUT.And,most importantly, think beforeyou act and be careful.For use with machines having Code Numbers:K2751-2, K2751-3, K2751-4,CK 2751-2, CK 2751-3, CK 2751-4,CK 2751-25, CK 2751-35Copyright © Lincoln Global Inc.vfor selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product •••as much pride as we have in bringing this product to you!TECHNICAL SPECIFICATIONS - DOWNFLEX 200/400GENERAL DESCRIPTIONThe downdraft table is a workbench with an integrated extraction fan and filtration system that is used for welding, grinding and plasma cutting applications. Depending on the specific application, the use of cer-tain accessories is required and/or recommended. See Accessories section of this manual.The downdraft table features a work grid, a three-stage prefiltration system for optimum spark arresting and two oval main filter cartridges. Both pre and main filters have dust drawers underneath. The working height of the downdraft table is adjustable. The control panel contains a 120V power outlet for connection of any device, such as a vacuum cleaner or grinding machine (max. 1200W).INTENDED USEThe product has been designed as a workbench with integrated extraction and filtration facility for welding and grinding purposes, provided the appropriate options have been installed (See Accessories Section of this manual). Using the product for other purposes is considered contrary to its intended use. The manufacturer accepts no liability for any damage or injury resulting from such use. The product has been built in accordance with state-of-the-art standards and recognized safety regulations. Only use this product when in technically perfect condition in accordance with its intended use and the instructions explained in the user manual.COMPONENTSThe downdraft table consists of the following main components See Figures A.1 and A.2:A. Backdraft kitB. Side panels (left + right)C. Work grid (two-piece)D. Control panelE. Left door (controls/fan)F. Power outletG. Right door (filter compartment)H. Compressed air tank (DownFlex 400-MS andDownFlex 400-MS/A only)I. Prefilters (1st stage)J. Dust drawers (prefiltration)K. Dust drawer (main filter cartridges)L. Filter cleaning mechanism (DownFlex 400-MS and DownFlex 400-MS/A only)M. Filter cartridges (2)N. Prefilters (2nd stage)CFGDEBAORQ PIN MJKLINSTALLATIONTOOLS AND REQUIREMENTSThe following tools and requirements are needed to install the product:• Spanner M6 and M8• Hexagon wrench 10 and 13 ( in.)UNPACKINGCheck that the product is complete. The package should contain:• Downdraft table • Work grid (two-piece)• Cover strip with 8 bolts M6 (cover strip not included when backdraft kit and side panels are standard equipment; bolts packed with backdraft kit)• Square key 8 mm (to lock/unlock doors)• Square key 6 mm (to lock/unlock dust drawers and doors of electrics)If parts are missing or damaged, contact your supplier.OPTIONSMount optional side panels, back panel, backdraft kit,and/or plasma cutting work grid, if any. Otherwise,refer to Work Grid for mounting of work grid.SIDE PANELSSide panels are to be mounted to the back panel or backdraft kit. See Figure A.3.To mount the side panels, proceed as follows.1. Unscrew the bolts on the loose side of the hinges and remove the washers; keep the bolts and wash-ers.2. Put the pins through the holes on the sides of the back panel or backdraft panel.3. Place the washers and bolts over the pins.4. Tighten the bolts.FIGURE A.3 –SIDE PANELSABPLASMA CUTTING WORK GRIDThe plasma cutting work grid consists of:• 2 Grid frames 28.9 x 26.3 x 2.5 in. (735 x 669 x 64mm)• 2 x 13 Metal bars 28.54 x 2.36 x 0.16 in. (725 x 60 x 4 mm)A CB ABC (x 26)3. Unlock the H EPA filter cartridge by pressing a screwdriver or other tool at the position of the strips (B) on the top and bottom of unit. See Figure A.8.4. Take out the filter cartridge.5. Mount the adjustable feet underneath the HEPA kit.NOTE:Remove the outlet panel from the HEPA kit, aswell as the outlet grid inside the downdraft table, to facilitate mounting. Donʼt forget to replace them when mounting is complete.6. Place bolts halfway through the 2 upper holes (C) at the outlet of the downdraft table. See Figure A.8.7. Hang the HEPA box on the bolts.8. Place bolts through the 2 lower holes (D) in the HEPA box. See Figure A.8.9. Fasten the H EPA box by tightening the 4 bolts (C+D). See Figure A.8.10. Replace the filter cartridge.11. Lock the filter cartridge by pulling the two strapstightly. This is indicated by a “click” sound.NOTE:If a Silencer/Outlet duct has to be installed aswell, the outlet panel of the HEPA kit does not need to be mounted.12. Adjust the feet when the downdraft table is placedin place in its final position.NOTE:The outlet panel of the downdraft table is notused.SILENCER/OUTLET DUCT The Silencer/Outlet duct consists of:B(2x)AC(x2)D(x2)B AC (x2)DE(x4)A (x 6)B (x 3)A (x 2)B (x 3)-r e a r--r e a r-FIGURE A.11 –CONNECTIONSCA BThe wheel kit consists of:• 2 Swivel casters with brakes• 3 Swivel casters without brakesTo mount the wheel kit, proceed as follows.1. Carefully lift the downdraft table using a fork-lifttruck or pallet jack.2. Unscrew the 5 adjustable feet.3. Mount the swivel casters; mount the ones withbrakes at the left and right front corners.NOTE:Drive in the screw thread of the swivel casters as deep as possible.NOTE:By the use of the wheel set, the working height of the downdraft table is fixed to 37.4 in. (950mm).COMPRESSED AIR CONNECTION (DownFlex 400-MS and DownFlex 400-MS/A only) The downdraft table functions on compressed air with a recommended working pressure of 72-115 psi (5-8 bar). Always make sure that the working pressure is between these values (preferably at 72 psi/5 bar). If required, mount a pressure reducing valve to prevent overpressure. If the pressure is too high, the safety valve of the system will be opened, thus decreasing the pressure until the system pressure has reached an appropriate level.1. Connect the downdraft table to compressed air.See Figure A.11, item C. Connection ⅜in. POSITIONINGThe downdraft table can be positioned using:• A fork-lift truck (preferred way); or• A pallet jack (downdraft table has to be tilted); or • Cargo lashings lifted by a fork-lift truck. See FigureA.14.AA ABYELLOWcomYELLOWcomBAinjury. After switching off the fan,wait at least 20 seconds beforeopening the door(s) to carry out ser-vice, maintenance or repair jobs.• Industrial vacuum cleaner used during service and maintenance should meet OSHA guidelines for Cr6 housekeeping.• Always use the downdraft table with prefilters, filter cartridges and dust drawers properly installed.------------------------------------------------------------------------CAUTIONFILTER REPLACEMENT1. During use, regularly check the Magnehelic gauge(B). When the pressure reaches 0.25 psi (1700Pa), the filter cartridges need to be replaced. See Figure B.2.2. Refer to Filter Replacement for the filter replace-ment procedure.FILTER CLEANING1. During use, regularly check the Magnehelic gauge(B). When the pressure reaches 0.22 psi (1500Pa), the filter cartridges need to be cleaned. See Figure B.3.Filter cleaning procedure:The filter cleaning procedure takes place online.1. Make sure the downdraft table is switched on.2. Press button FILTER CLEANING (D) for 5 secondsto activate the filter cleaning system. See FigureB.3.The filter cleaning procedure takes 2 minutes, during which each filter cartridge is cleaned by 7 compressed air pulses.NOTE:To secure optimum filter efficiency, do not acti-vate the filter cleaning system within the first 20hours of operation or within 20 hours after filterreplacement.1. Check the pressure on the Magnehelic gauge (B). Ifthe pressure still exceeds 0.22 psi (1500 Pa), repeat the filter cleaning procedure (max. 5 times).See Figure B.3.FILTER REPLACEMENTIf the filter cleaning system is unable to get the pres-sure below 0.22 psi (1500 Pa) after 5 attempts, the fil-ter cartridges are probably saturated and need to be replaced.1. Push the ON/OFF button (C) to switch off the fan.See Figure B.3.2. Wait 20 seconds for fan to stop rotating.3. Turn switch (A) off to remove the main input power.4. Refer to Filter Replacement for the filter replace-ment procedure.AUTOMATIC FILTER CLEANINGEach time the downdraft table is switched off, the filter cartridges are automatically cleaned by a full cleaning cycle. This procedure takes approximately 7 minutes, during which each filter cartridge is cleaned by max. 10 compressed air blasts.NOTE:To secure optimum filter efficiency the filter cleaning system will not be activated during thefirst 20 hours of operation or within 20 hoursafter filter replacement.MANUAL FILTER CLEANINGIf desired, the filter cleaning system can be activated manually (online cleaning only).1. Push the ON/OFF button (C) to switch on the fan.See Figure B.4.2. Press button RESET ALARM/MANUAL CLEANING(D) during 5 seconds to activate the filter cleaningsystem. See Figure B.4.This procedure takes approximately 4 minutes, during which each filter cartridge is cleaned by 6 compressed air blasts.NOTE:To secure optimum filter efficiency the filter cleaning system cannot be activated during thefirst 20 hours of operation or within 20 hoursafter filter replacement.BUZZERThe buzzer may emit two different interrupted sounds:• 2 Seconds on - 2 seconds off: clogged filter• 2 Seconds on - 5 seconds off: compressed air miss-ingWhen the pressure over the filter cartridges reaches 0.22 psi (1500 Pa) during use, the buzzer will emit an interrupted sound (2 seconds on - 2 seconds off). In this case proceed as follows.1. Press button RESET ALARM/MANUAL CLEANING(D) to deactivate the buzzer. See Figure B.4.2. Push the ON/OFF button (C) to switch off the fan.See Figure B.4.After the fan has been switched off, the automatic filter cleaning procedure will be activated. See Automatic Filter Cleaning.NOTE:Buzzer sound is suppressed during one hour enabling the user to finish his job. If neces-sary/desired, buzzer can be suppressed(repeatedly), provided that the downdraft tableis switched off by ON/OFF button at the end ofthe day.NOTE:When welding/grinding and cleaning is finished turn switch (A) off to remove the main inputpower.FILTER REPLACEMENTWhen the filter cleaning system is unable to get the pressure below 0.22 psi (1500 Pa) after 5 attempts, the filter cartridges are probably saturated and need to be replaced. This is indicated by the buzzer emitting an interrupted sound (2 seconds on - 2 seconds off).1. Press button RESET ALARM/MANUAL CLEANING(D) to deactivate the buzzer (E). See Figure B.4.2. Push the ON/OFF button (C) to switch off the fan.See Figure B.4.3. Wait 20 seconds for fan to stop rotating.4. Refer to Filter Replacement for the filter replace-ment procedure.B E FH IL (x 5)C (x 2)This Troubleshooting Guide is provided to help you locate and repair possible machine malfunctions.Simply follow the three-step procedure listed below.Step 1.LOCATE PROBLEM (SYMPTOM).Look under the column labeled “PROBLEM (SYMP-TOMS)”. This column describes possible symptoms that the machine may exhibit. Find the listing that best describes the symptom that the machine is exhibiting. Step 2.POSSIBLE CAUSE.The second column labeled “POSSIBLE CAUSE” lists the obvious external possibilities that may contribute to the machine symptom.Step 3.RECOMMENDED COURSE OF ACTIONThis column provides a course of action for the Possible Cause, generally it states to contact your local Lincoln Authorized Field Service Facility.If you do not understand or are unable to perform the Recommended Course of Action safely, contact your local Lincoln Authorized Field Service Facility.HOW TO USE TROUBLESHOOTING GUIDEService and Repair should only be performed by Lincoln Electric Factory Trained Personnel.Unauthorized repairs performed on this equipment may result in danger to the technician and machine operator and will invalidate your factory warranty. For your safety and to avoid Electrical Shock, please observe all safety notes and precautions detailed throughout this manual.__________________________________________________________________________* Text printed in Bold refers to options and accessories.* Text printed in Bold refers to options and accessories.JapaneseChineseKoreanArabicREAD AND UNDERSTAND THE MANUFACTURERʼS INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYERʼS SAFETY PRACTICES.SE RECOMIENDA LEER Y ENTENDER LAS INSTRUCCIONES DEL FABRICANTE PARA EL USO DE ESTE EQUIPO Y LOS CONSUMIBLES QUE VA A UTILIZAR, SIGA LAS MEDIDAS DE SEGURIDAD DE SU SUPERVISOR.LISEZ ET COMPRENEZ LES INSTRUCTIONS DU FABRICANT EN CE QUI REGARDE CET EQUIPMENT ET LES PRODUITS A ETRE EMPLOYES ET SUIVEZ LES PROCEDURES DE SECURITE DE VOTRE EMPLOYEUR.LESEN SIE UND BEFOLGEN SIE DIE BETRIEBSANLEITUNG DER ANLAGE UND DEN ELEKTRO-DENEINSATZ DES HERSTELLERS. DIE UNFALLVERHÜTUNGSVORSCHRIFTEN DES ARBEITGEBERS SIND EBENFALLS ZU BEACHTEN.JapaneseChineseKoreanArabicLEIA E COMPREENDA AS INSTRUÇÕES DO FABRICANTE PARA ESTE EQUIPAMENTO E AS PARTES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR.。
第一节概述TK200井下通讯、控制、保护系统是在我厂TK100工作面及皮带通讯、控制一体化系统基础上,重新开发研制的新一代产品。
可实现工作面、顺槽皮带、大皮带等的保护,控制、沿线通话、故障检测、显示及报警等功能。
从工作面到顺槽,从单条运输皮带到整个矿井的所有固定皮带,从简单的皮带头尾搭接到“丁”字型、“山”字型搭接,从设备启、停控制到工作电流、电压显示、皮带速度检测和显示、煤仓煤位检测、显示、高低煤位停机,油温、油压、轴温等的检测和显示及计算机远程通信,故障自诊断等等,TK200均可提供全套解决方案。
(一)系统组成:TK200由以下设备及子系统构成:1.TK200控制、显示中心2.拉线急停、沿线闭锁、通话子系统。
3.智能输入、输出(用于远距离输入、输出)。
4.智能耦合器5.皮带控制器(待开发)6.皮带张紧(可由参数设置为自动张紧、手动张紧、朗艾道自动张紧等)7.传感器子系统(二)系统功能:TK200系统可完成:1.工作面各设备的启停状态检测和显示。
包括:(1)采煤机、前后部运输机、破碎机、转载机、泵、皮带的启停等。
(2)配接我厂的“TJ100设备工作电流检测仪”后,可对以上设备的工作电流进行检测、显示及过载后进行语言报警。
2.检测结果的显示控制计算机对以上参数检测后,在TK200控制中心的10.4”大屏幕彩色液晶平板显示器上显示出来。
(以图形、动画的形式显示设备启停情况,以不同的颜色表示过载情况。
)3.设备启停时间统计、显示。
4.设备启停控制。
通过按键,可对破碎、转载、前后部运输机及泵等设备进行启停控制。
5.报警设备启动前,以及发生各种故障时进行报警,报警时间的长短可以通过参数设定。
6.将工作面各设备工作状态和参数传输给井上,在井上计算机进行显示。
7.皮带控制包括六大保护,皮带启停、皮带张紧(可由参数设置为自动张紧、手动张紧或朗艾道型自动张紧)、软启动控制、电机温度检测和显示、皮带沿线拉线闭锁。
感谢您使用迪凯科技系列产品,当您准备使用本产品时请务必仔细阅读本说明。
并按照所提供的有关操作步骤进行操作,使您能充分享受我公司提供的服务,同时避免您的误操作而损坏本机或发生其它意外。
请妥善保管本手册,以便在您日后需要时能及时查阅、获得帮助。
版权声明本手册版权属郑州迪凯科技有限公司所有,未经书面许可,本手册任何部分不得复制、翻译、存储于数据库或检索系统内,也不可以电子、翻拍、录音等任何手段及方式进行传播。
郑州迪凯科技有限公司秉承科技进步原则,不断致力于产品改进、提高产品性能,公司保留任何产品改进而不预先通知的权利。
我们已尽最大努力准备本手册以确保其准确性,仍无法保证不出现疏漏,如发现任何不妥请及时与我公司联系。
对于本手册如有不同理解,以本公司技术部门解释为准。
本手册内容可能有所更改,届时恕不另行通知。
用户服务指引:1,在使用本产品前,请根据产品出厂清单仔细核对附件、产品合格证及用户保修卡是否齐全,若发现不全,请立即与销售商或厂家联络。
2,本产品自售出之日起十二个月内,凡用户遵守贮存、运输及使用要求,而产品质量低于技术指标的,凭保修单享受免费维修。
3,因违反操作规定和要求而造成的损坏、非我公司指定的特约技术服务部维修引起的故障或由于不可抗拒因素引起的产品质量问题,我公司将进行收费维修。
4,产品进行维修时,请主动出示产品保修卡。
不能出示产品保修卡的将作为收费维修。
5,产品维护、维修后,请出示本手册,维修人员将填写所附的《维护、维修情况纪录》并签名;同时也请您在维修人员的《维护、维修情况纪录》上签名确认维护、维修内容并提出宝贵意见,如果是单位用户,请加盖公章。
6,如果您对我们提供的产品和服务有任何疑问或不满,包括产品技术、质量、安装维修、服务态度、收费标准等问题,请您及时联络我们,我们将会对您的意见妥善处理。
目录1 产品概述2 主要功能及技术指标2.1主要功能2.2技术指标3 控制器结构及安装3.1 外形图3.2 功能键3.3 安装方法4 系统配置及接线4.1 系统配置4.2 系统接线5 系统使用5.1 开机5.2 查询报警记录5.3 时间设置5.4 报警设置5.5 系统参数设置5.6 恢复出厂设置5.7 帮助6 常见故障及解决办法7 随机配件8 注意事项附表:气体选型表1产品概述GBK200气体报警控制器是我公司研制的多点监控气体报警系统,由气体检测控制主机和气体探测器构成,用于检测作业环境中可燃性气体浓度、氧气浓度或者有毒有害气体浓度的仪器,可带多个气体检测探测器,并同时对多点进行集中控制。
Instructions on reverse >>Wimberley, Inc. ©2017, All Rights ReservedRev. 170707C K -200C K -200 F u l l G i m b a l K i tF u l lG i m b a l C o n v e r s i o n K i tAYou are now ready to use the Wimberley Head Version II: there are important balancing differences between the two types of Heads. Please refer to the included product instructions for the Wimberley Head Version II (WH -200) prior to use.About the CK -200:This kit allows you to replace the Wimberley quick -release clamp on the Sidemount Wimberley Head (WH -200-S) with the swinging arm and platform of the full gimbal Wimberley Head (WH -200).The procedure is simple, and the only tool required is a 5/32 hex key which is included. Please read these instructions carefully to make sure that you remove the appropriate parts from your Head and install the new parts properly.Note: do not fully tighten the Platform wing knob when it is not attached to the Swing Arm.Instructions:Tip: Keep the clamp and extra screws handy so that you can convert the Head back to the Sidemount when shooting conditions require a lighter, more compact set up.Thank you for your interest in Wimberley products. If you have any questions or comments please feel free to contact us.The two extra screws that come with this kit are identi-cal to those removed and are provided in case of loss.Attaching the Platform:1. Slide the female dovetail of the platform onto the male dovetail ofthe arm all the way until it stops. Note: Be sure to ensure that the platform jaws are aligned with the swing arm dovetail. 2. Tighten the wing -knob on the platform to secure the connection(there should be no need to over -tighten the wing knob). The image to the right shows the Arm and Platform properly assembled.Removing the Sidemount Quick -Release:Use the included hex key to remove the two screws that attach the quick -release to the Head (see picture below).Once the screws are removed, the clamp should come off easily.Attaching the Swing Arm: Attach the Swing Arm to your Wimberley Head using the screws that you just removed and the provided hex key.。
0XJ 461 222第 2 页共 11 页旧底图总号底图总号签字日期于5A;b.在电压不大于250V,电流不大于2A的交流回路(c o sφ=0.4±0.1)中触点断开容量为250VA,长期允许通过电流不大于5A。
3.3 辅助电源:220V或110V(交直流通用)。
3.4平均无故障工作时间:≥50000h。
3.5 环境条件a. 环境温度:工作: -25℃~+55℃。
储存: -25℃~+70℃,相对湿度不大于80%,周围空气中不含有酸性、碱性或其它腐蚀性及爆炸性气体的防雨、防雪的室内;在极限值下不施加激励量,装置不出现不可逆转的变化,温度恢复后,装置应能正常工作。
b. 相对湿度:最湿月的月平均最大相对湿度为90%,同时该月的月平均最低温度为25℃且表面不凝露。
最高温度为+40℃时,平均最大湿度不超过50%。
c.大气压力:80kPa~110kPa(相对海拔高度2km以下)。
3.6 抗干扰性能a. 装置能承受GB/T 14598.14-1998第4章规定的严酷等级为Ⅲ级的静电放电干扰试验;b. 装置能承受GB/T 14598.9-2002第4章规定的严酷等级的辐射电磁场干扰试验;c. 装置能承受GB/T 14598.10-2007第4章规定的严酷等级为B级的快速瞬变干扰试验;d. 装置能承受GB/T 14598.13-2008规定的频率为1M Hz及100kHz(第一半波电压幅值共模为2.5kV,差模为1kV)脉冲群干扰试验;e. 装置能承受IE C 60255-22-5:2002第4章规定的严酷等级的浪涌抗扰度试验;f. 装置能承受GB/T14598.17-2005第4章规定的严酷等级的传导骚扰抗扰度试验;g. 装置能承受IE C 60255-22-7:2003第4章规定的严酷等级的工频抗扰度试验;h. 装置能承受GB/T 17626.8-2006第5章规定的严酷等级为Ⅳ级的工频磁场抗扰度试验;i. 装置能承受GB/T 17626.9-1998第5章规定的严酷等级为Ⅳ级的脉冲磁场抗扰度试验;j. 装置能承受GB/T17626.10-1998第5章规定的严酷等级为Ⅳ级的阻尼振荡磁场抗扰度试验。
KOC200系列电机软起动器深圳市科创力源电子有限公司SHENZHEN KCLY ELECTRIC CO., LTD.地址:深圳市龙岗区上雪科技工业城东区8号A栋5楼电话:0755-********传真:0755-********网址:邮箱:info@.cn深圳市科创力源电子有限公司KOC200系列软起动说明书前言前言感谢您选用本公司的智能化电机软启动器产品,该产品用于三相鼠笼式异步电动机软起、软停控制,在使用前请仔细阅读和理解本说明书中的内容。
在本软启动产品的安装、使用、维护过程中必须注意以下事项:安装前请务必详细阅读本操作说明。
必须由专业技术人员安装本软启动器。
必须让电动机的规格与本软启动器相匹配。
严禁在软启动器输出端(U.V.W) 接电容器。
安装后裸露的接线端子必须用绝缘胶带包好。
软启动器或相关的其他设备应可靠接地。
设备维修时必须切断输入电源。
不得私自拆卸、改装、维修本产品。
本使用说明书中内容可能会因技术原因随时变更或修改。
我们保留更改的权力。
目录KOC200系列软起动说明书目录第1章KOC200系列电机软启动器 (1)1.1软启动器概况 (1)1.2软启动器的主要作用 (1)1.3软启动器的主要特点 (1)1.4软启动器的主要技术参数 (2)第2章产品型号说明与开箱检查 (3)第3章使用条件与安装要求 (4)3.1软启动器的使用条件 (4)3.2软启动器的安装要求 (4)3.3软启动器的外形与安装尺寸 (5)3.4软启动器的安装实图 (6)第4章外接端子与通信接口说明 (8)4.1软启动器外接端子说明 (8)4.2软启动器主回路接线简图 (9)4.3软启动器通讯接口与说明 (10)第5章控制面板与操作 (11)5.1键盘操作方法 (11)5.2参数设置与说明 (12)5.3可编程继电输出功能 (14)5.4其它设置项说明 (15)5.5帮助信息及说明 (15)5.6成套厂家出厂或用户调试方案 (16)第6章保护功能及说明 (17)6.1保护功能及其参数 (17)6.2保护级别设定说明 (17)第7章试运行与应用 (19)7.1通电试运行 (19)7.2起动模式及应用 (20)7.3停机模式及应用 (23)7.4特殊应用 (23)7.5应用举例 (24)附录 (25)保修协议 (29)KOC200系列软起动说明书第1章KOC200电机软启动器第1章KOC200系列电机软启动器1.1软启动器概况电机软启动器概况:智能化数字式电机软启动器,采用智能化数字式控制;以单片机为智能中心,可控硅模块为执行元件对电动机进行全自动控制。
诚科ck200温控器设置说明书
以下是诚科CK200温控器的设置说明书:
温度设定
1. 按下设置键,屏幕显示温度设定值,同时闪烁。
2. 按下“+”、“-”调整所需温度设定值。
3. 确认设定值后按设置键,恢复初始状态。
工作模式选择
1. 按下设置键,屏幕显示工作模式设定值,同时闪烁。
2. 按下“+”、“-”调整所需工作模式。
编号工作模式描述
P0 制冷模式制冷期间关闭输出,停止加热电源,恒定监测温度状态。
P1 发酵模式平衡停机温度预热时间1-999(分钟),制冷点到高温点不开启加热,高温点到停机点开启加热输出。
P2 蒸发模式开启冷却输出,高温点到停机点开启加热输出。
P3 加热模式常规双点控制模式,普遍使用的模式。
3. 确认设定值后按设置键,恢复初始状态。
恢复出厂设置
1. 系统关闭后按住“+”、“-”、“设置”键3秒以上,闪存执行格式化即恢复出厂设置。